Abstract

Purpose To assess the performance of hardware- and software-gating technologies in terms of qualitative and quantitative characteristics of respiratory motion in positron emission tomography (PET) imaging. Materials and Methods Between 2010 and 2013, 219 fluorine 18 fluorodeoxyglucose PET examinations were performed in 116 patients for assessment of pulmonary nodules. All patients provided informed consent in this institutional review board-approved study. Acquisitions were reconstructed as respiratory-gated images by using hardware-derived respiratory triggers and software-derived signal (via an automated postprocessing method). Asymmetry was evaluated in the joint distribution of reader preference, and linear mixed models were used to evaluate differences in outcomes according to gating type. Results In blind reviews of reconstructed gated images, software was selected as superior 16.9% of the time (111 of 657 image sets; 95% confidence interval [CI]: 14.0%, 19.8%), and hardware was selected as superior 6.2% of the time (41 of 657 image sets; 95% CI: 4.4%, 8.1%). Of the image sets, 76.9% (505 of 657; 95% CI: 73.6%, 80.1%) were judged as having indistinguishable motion quality. Quantitative analysis demonstrated that the two gating strategies exhibited similar performance, and the performance of both was significantly different from that of nongated images. The mean increase ± standard deviation in lesion maximum standardized uptake value was 42.2% ± 38.9 between nongated and software-gated images, and lesion full width at half maximum values decreased by 9.9% ± 9.6. Conclusion Compared with vendor-supplied respiratory-gating hardware methods, software gating performed favorably, both qualitatively and quantitatively. Fully automated gating is a feasible approach to motion correction of PET images. (©) RSNA, 2016 Online supplemental material is available for this article.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2016152105

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 61

Metadata

Authors
Kesner, A. L., Chung, J. H., Lind, K. E., Kwak, J. J., Lynch, D., Burckhardt, D., & Koo, P. J.
Venue
Radiology
Published
2016-10
Volume
281
Issue
1
Pages
239-248
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2328679836
Cited by
61
References
2
FWCI
7.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of Software Gating: A Practical Technology for Respiratory Motion Correction in PET. https://app.cochat.ai/papers/10.1148/radiol.2016152105
The paper
Kesner, A. L., Chung, J. H., Lind, K. E., Kwak, J. J., Lynch, D., Burckhardt, D., & Koo, P. J. (2016). Validation of Software Gating: A Practical Technology for Respiratory Motion Correction in PET. Radiology. https://doi.org/10.1148/radiol.2016152105

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.