Supplemental Breast MR Imaging Screening of Women with Average Risk of Breast Cancer

Kuhl, Christiane K., Strobel, Kevin, Bieling, Heribert, Leutner, Claudia, Schild, Hans H., Schrading, Simone·2017·Radiology

Abstract

Purpose To investigate the utility and accuracy of breast magnetic resonance (MR) imaging as a supplemental screening tool in women at average risk for breast cancer and to investigate the types of cancer detected with MR imaging screening. Materials and Methods This prospective observational study was conducted at two academic breast centers in women aged 40–70 years without breast cancer–associated risk factors (lifetime risk <15%). Between January 2005 and December 2013, women with at least minimal residual breast tissue (American College of Radiology categories A–D) and normal conventional imaging findings (screening mammography with or without screening ultrasonography [US]) were invited to undergo supplemental MR imaging screening. Outcome measures were supplemental cancer detection rates, interval cancer rates, and biologic profiles of MR imaging–detected additional cancers, as well as specificity and positive predictive value (PPV) of MR imaging screening. Tissue diagnoses or 2 years of follow-up were used to establish the reference standard. Results A total of 2120 women were recruited and underwent 3861 screening MR imaging studies, covering an observation period of 7007 women-years. Breast MR imaging depicted 60 additional breast cancers (ductal carcinoma in situ, n = 20; invasive carcinoma, n = 40) for an overall supplemental cancer detection rate of 15.5 per 1000 cases (95% confidence interval [CI]: 11.9, 20.0). Forty-eight additional cancers were detected with MR imaging at initial screening (supplemental cancer detection rate, 22.6 per 1000 cases). During the 1741 subsequent screening rounds, 12 of 13 incident cancers were found with MR imaging alone (supplemental cancer detection rate, 6.9 per 1000 cases). One cancer was diagnosed with all three methods (mammography, US, and MR imaging), and none were diagnosed with mammography only or US only. Cancers diagnosed with MR imaging were small (median, 8 mm), node negative in 93.4% of cases, and dedifferentiated (high-grade cancer) in 41.7% of cases at prevalence screening and 46.0% of cases at incidence screening. No interval cancers were observed. MR imaging screening offered high specificity (97.1%; 95% CI: 96.5, 97.6) and high PPV (35.7%; 95% CI: 28.9, 43.1). Conclusion In women at average risk for breast cancer, MR imaging screening improves early diagnosis of prognostically relevant breast cancer. © RSNA, 2017 Online supplemental material is available for this article.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2016161444

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 350

Metadata

Authors
Kuhl, C. K., Strobel, K., Bieling, H., Leutner, C., Schild, H. H., & Schrading, S.
Venue
Radiology
Published
2017-05
Volume
283
Issue
2
Pages
361-370
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2590836720
Cited by
350
References
31
Type
supplementary materials
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Supplemental Breast MR Imaging Screening of Women with Average Risk of Breast Cancer. https://app.cochat.ai/papers/10.1148/radiol.2016161444
The paper
Kuhl, C. K., Strobel, K., Bieling, H., Leutner, C., Schild, H. H., & Schrading, S. (2017). Supplemental Breast MR Imaging Screening of Women with Average Risk of Breast Cancer. Radiology. https://doi.org/10.1148/radiol.2016161444

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.