Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 679

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abbreviated Breast Magnetic Resonance Imaging (MRI): First Postcontrast Subtracted Images and Maximum-Intensity Projection—A Novel Approach to Breast Cancer Screening With MRI

Kuhl, Christiane K., Schrading, Simone, Strobel, Kevin, Schild, Hans H., Hilgers, Ralf-Dieter, Bieling, Heribert B.·2014·Journal of Clinical Oncology

Abstract

Purpose: We investigated whether an abbreviated protocol (AP), consisting of only one pre- and one postcontrast acquisition and their derived images (first postcontrast subtracted [FAST] and maximum-intensity projection [MIP] images), was suitable for breast magnetic resonance imaging (MRI) screening. Methods: We conducted a prospective observational reader study in 443 women at mildly to moderately increased risk who underwent 606 screening MRIs. Eligible women had normal or benign digital mammograms and, for those with heterogeneously dense or extremely dense breasts (n = 427), normal or benign ultrasounds. Expert radiologists reviewed the MIP image first to search for significant enhancement and then reviewed the complete AP (consisting of MIP and FAST images and optionally their nonsubtracted source images) to characterize enhancement and establish a diagnosis. Only thereafter was the regular full diagnostic protocol (FDP) analyzed. Results: MRI acquisition time for FDP was 17 minutes, versus 3 minutes for the AP. Average time to read the single MIP and complete AP was 2.8 and 28 seconds, respectively. Eleven breast cancers (four ductal carcinomas in situ and seven invasive cancers; all T1N0 intermediate or high grade) were diagnosed, for an additional cancer yield of 18.2 per 1,000. MIP readings were positive in 10 (90.9%) of 11 cancers and allowed establishment of the absence of breast cancer, with a negative predictive value (NPV) of 99.8% (418 of 419). Interpretation of the complete AP, as with the FDP, allowed diagnosis of all cancers (11 [100%] of 11). Specificity and positive predictive value (PPV) of AP versus FDP were equivalent (94.3% v 93.9% and 24.4% v 23.4%, respectively). Conclusion: An MRI acquisition time of 3 minutes and an expert radiologist MIP image reading time of 3 seconds are sufficient to establish the absence of breast cancer, with an NPV of 99.8%. With a reading time < 30 seconds for the complete AP, diagnostic accuracy was equivalent to that of the FDP and resulted in an additional cancer yield of 18.2 per 1,000.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1200/jco.2013.52.5386

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 679

Metadata

Authors
Kuhl, C. K., Schrading, S., Strobel, K., Schild, H. H., Hilgers, R.-D., & Bieling, H. B.
Venue
Journal of Clinical Oncology
Published
2014-08-01
Volume
32
Issue
22
Pages
2304-2310
ISSN
  • 0732-183X (ISSN-L)
  • 1527-7755
OpenAlex
W2141798739
Cited by
679
References
28
FWCI
32.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Abbreviated Breast Magnetic Resonance Imaging (MRI): First Postcontrast Subtracted Images and Maximum-Intensity Projection—A Novel Approach to Breast Cancer Screening With MRI. https://app.cochat.ai/papers/10.1200/jco.2013.52.5386
The paper
Kuhl, C. K., Schrading, S., Strobel, K., Schild, H. H., Hilgers, R.-D., & Bieling, H. B. (2014). Abbreviated Breast Magnetic Resonance Imaging (MRI): First Postcontrast Subtracted Images and Maximum-Intensity Projection—A Novel Approach to Breast Cancer Screening With MRI. Journal of Clinical Oncology. https://doi.org/10.1200/jco.2013.52.5386

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.