The Use and Pitfalls of Intracranial Vessel Wall Imaging: How We Do It
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Intracranial vessel wall magnetic resonance (MR) imaging has gained much attention in the past decade and has become part of state-of-the-art MR imaging protocols to assist in diagnosing the cause of ischemic stroke. With intracranial vessel wall imaging, vessel wall characteristics have tentatively been described for atherosclerosis, vasculitis, dissections, Moyamoya disease, and aneurysms. With the increasing demand and subsequently increased use of intracranial vessel wall imaging in clinical practice, radiologists should be aware of the choices in imaging parameters and how they affect image quality, the clinical indications, methods of assessment, and limitations in the interpretation of these images. In this How I do It article, the authors will discuss the technical requirements and considerations for vessel wall image acquisition in general, describe their own vessel wall imaging protocol at 3 T and 7 T, show a step-by-step basic assessment of intracranial vessel wall imaging as performed at their institution-including commonly encountered artifacts and pitfalls-and summarize the commonly reported imaging characteristics of various intracranial vessel wall diseases for direct clinical applicability. Finally, future technical and clinical considerations for full implementation of intracranial vessel wall imaging in clinical practice, including the need for histologic validation and acquisition time reduction, will be discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Comparison of Warfarin and Aspirin for Symptomatic Intracranial Arterial Stenosis
Chimowitz, M. I., Lynn, M. J., Howlett-Smith, H., Stern, B. J., Hertzberg, V. S., Frankel, M. R., Levine, S. R., Chaturvedi, S., Kasner, S. E., Benesch, C. G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043033 · Cited by 1,744
Derdeyn, C. P., Chimowitz, M. I., Lynn, M. J., Fiorella, D., Turan, T. N., Janis, L. S., Montgomery, J., Nizam, A., Lane, B. F., Lutsep, H. L., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(13)62038-3 · Cited by 881
Reversible cerebral vasoconstriction syndrome
Ducros, A. (2012) · The Lancet Neurology · doi:10.1016/s1474-4422(12)70135-7 · Cited by 838
Mandell, D. M., Mossa-Basha, M., Qiao, Y., Hess, C. P., Hui, F., Matouk, C., Johnson, M. H., Daemen, M. J. A. P., Vossough, A., Edjlali, M., et al. (2017) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4893 · Cited by 691 · cited 5×
“Use of Contrast Agents The use of contrast material–enhanced MR imaging is considered a necessary component of VW imaging protocols (1,2).”
BackgroundMethodInfluentialConsensus recommendations for a standardized Brain Tumor Imaging Protocol in clinical trials
(2015) · Neuro-Oncology · doi:10.1093/neuonc/nov095 · Cited by 663
Gorelick, P. B., Wong, K. S., Bae, H.-J., & Pandey, D. K. (2008) · Stroke · doi:10.1161/strokeaha.107.505776 · Cited by 661 · cited 3×
“Approved for THREE (3) Clinical Continuing Educational Units (CEU’s)”
BackgroundInfluentialAtherosclerotic intracranial arterial stenosis: risk factors, diagnosis, and treatment
Holmstedt, C. A., Turan, T. N., & Chimowitz, M. I. (2013) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70195-9 · Cited by 484
Qureshi, A. I., & Caplan, L. R. (2014) · The Lancet · doi:10.1016/s0140-6736(13)61088-0 · Cited by 395
Qiao, Y., Zeiler, S. R., Mirbagheri, S., Leigh, R., Urrutia, V., Wityk, R., & Wasserman, B. A. (2014) · Radiology · doi:10.1148/radiol.13122812 · Cited by 329
Metadata
- Authors
- Lindenholz, A., van der Kolk, A. G., Zwanenburg, J. J. M., & Hendrikse, J.
- Venue
- Radiology
- Published
- 2018-01
- Volume
- 286
- Issue
- 1
- Pages
- 12-28
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2776026989
- Cited by
- 224
- References
- 53
- FWCI
- 10.60
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Use and Pitfalls of Intracranial Vessel Wall Imaging: How We Do It. https://app.cochat.ai/papers/10.1148/radiol.2017162096
- The paper
- Lindenholz, A., van der Kolk, A. G., Zwanenburg, J. J. M., & Hendrikse, J. (2018). The Use and Pitfalls of Intracranial Vessel Wall Imaging: How We Do It. Radiology. https://doi.org/10.1148/radiol.2017162096
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.