The Use and Pitfalls of Intracranial Vessel Wall Imaging: How We Do It
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Intracranial vessel wall magnetic resonance (MR) imaging has gained much attention in the past decade and has become part of state-of-the-art MR imaging protocols to assist in diagnosing the cause of ischemic stroke. With intracranial vessel wall imaging, vessel wall characteristics have tentatively been described for atherosclerosis, vasculitis, dissections, Moyamoya disease, and aneurysms. With the increasing demand and subsequently increased use of intracranial vessel wall imaging in clinical practice, radiologists should be aware of the choices in imaging parameters and how they affect image quality, the clinical indications, methods of assessment, and limitations in the interpretation of these images. In this How I do It article, the authors will discuss the technical requirements and considerations for vessel wall image acquisition in general, describe their own vessel wall imaging protocol at 3 T and 7 T, show a step-by-step basic assessment of intracranial vessel wall imaging as performed at their institution-including commonly encountered artifacts and pitfalls-and summarize the commonly reported imaging characteristics of various intracranial vessel wall diseases for direct clinical applicability. Finally, future technical and clinical considerations for full implementation of intracranial vessel wall imaging in clinical practice, including the need for histologic validation and acquisition time reduction, will be discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Comparison of Warfarin and Aspirin for Symptomatic Intracranial Arterial Stenosis
Chimowitz, M. I., Lynn, M. J., Howlett-Smith, H., Stern, B. J., Hertzberg, V. S., Frankel, M. R., Levine, S. R., Chaturvedi, S., Kasner, S. E., Benesch, C. G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043033 · Cited by 1,744
Derdeyn, C. P., Chimowitz, M. I., Lynn, M. J., Fiorella, D., Turan, T. N., Janis, L. S., Montgomery, J., Nizam, A., Lane, B. F., Lutsep, H. L., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(13)62038-3 · Cited by 881
Reversible cerebral vasoconstriction syndrome
Ducros, A. (2012) · The Lancet Neurology · doi:10.1016/s1474-4422(12)70135-7 · Cited by 838
Mandell, D. M., Mossa-Basha, M., Qiao, Y., Hess, C. P., Hui, F., Matouk, C., Johnson, M. H., Daemen, M. J. A. P., Vossough, A., Edjlali, M., et al. (2017) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4893 · Cited by 691 · cited 5×
“Use of Contrast Agents The use of contrast material–enhanced MR imaging is considered a necessary component of VW imaging protocols (1,2).”
BackgroundMethodInfluentialConsensus recommendations for a standardized Brain Tumor Imaging Protocol in clinical trials
(2015) · Neuro-Oncology · doi:10.1093/neuonc/nov095 · Cited by 663
Gorelick, P. B., Wong, K. S., Bae, H.-J., & Pandey, D. K. (2008) · Stroke · doi:10.1161/strokeaha.107.505776 · Cited by 661 · cited 3×
“Approved for THREE (3) Clinical Continuing Educational Units (CEU’s)”
BackgroundInfluentialAtherosclerotic intracranial arterial stenosis: risk factors, diagnosis, and treatment
Holmstedt, C. A., Turan, T. N., & Chimowitz, M. I. (2013) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70195-9 · Cited by 484
Qureshi, A. I., & Caplan, L. R. (2014) · The Lancet · doi:10.1016/s0140-6736(13)61088-0 · Cited by 395
Qiao, Y., Zeiler, S. R., Mirbagheri, S., Leigh, R., Urrutia, V., Wityk, R., & Wasserman, B. A. (2014) · Radiology · doi:10.1148/radiol.13122812 · Cited by 329
Obusez, E. C., Hui, F. K., Hajj‐Ali, R. A., et al. (2014) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3909 · Cited by 270
Clinical applications of 7T MRI in the brain
van der Kolk, A. G., Hendrikse, J., Zwanenburg, J. J. M., Visser, F., & Luijten, P. R. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.07.007 · Cited by 268
Self-citationQiao, Y., Steinman, D. A., Qin, Q., Etesami, M., Schär, M., Astor, B. C., & Wasserman, B. A. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22592 · Cited by 267
Cause and Mechanisms of Intracranial Atherosclerosis
Ritz, K., Denswil, N. P., Stam, O. C. G., van Lieshout, J. J., & Daemen, M. J. A. P. (2014) · Circulation · doi:10.1161/circulationaha.114.011147 · Cited by 243 · cited 1×
“Several case series have shown the possibility of detecting intraplaque hemorrhage (22,89–93); however, postmortem studies suggest that intraplaque hemorrhage has a lower prevalence in intracranial plaques compared with extracranial (carotid) plaques (6,47,94); therefore, its role so far remains elusive.”
BackgroundIntracranial Atherosclerosis: Current Concepts
Arenillas, J. F. (2011) · Stroke · doi:10.1161/strokeaha.110.597278 · Cited by 234 · cited 1×
“How accurate is CT angiography in evaluating intracranial atherosclerotic disease? Stroke 2008;39(4):1184–1188.”
BackgroundHow Accurate Is CT Angiography in Evaluating Intracranial Atherosclerotic Disease?
Nguyen-Huynh, M. N., Wintermark, M., English, J., Lam, J., Vittinghoff, E., Smith, W. S., & Johnston, S. C. (2008) · Stroke · doi:10.1161/strokeaha.107.502906 · Cited by 228
Quantitative assessment of the effects of high‐permittivity pads in 7 Tesla MRI of the brain
Teeuwisse, W. M., Brink, W. M., & Webb, A. G. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23108 · Cited by 225
Xu, W.-H., Li, M.-L., Gao, S., Ni, J., Zhou, L.-X., Yao, M., Peng, B., Feng, F., Jin, Z.-Y., & Cui, L.-Y. (2010) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2010.06.035 · Cited by 224
Intracranial Carotid Artery Atherosclerosis and the Risk of Stroke in Whites: The Rotterdam Study
Bos, D., Portegies, M. L. P., van der Lugt, A., Bos, M. J., Koudstaal, P. J., Hofman, A., Krestin, G. P., Franco, O. H., Vernooij, M. W., & Ikram, M. A. (2014) · JAMA Neurology · doi:10.1001/jamaneurol.2013.6223 · Cited by 213
Patterns and Implications of Intracranial Arterial Remodeling in Stroke Patients
Qiao, Y., Anwar, Z., Intrapiromkul, J., Liu, L., Zeiler, S. R., Leigh, R. J., Zhang, Y., Güallar, E., & Wasserman, B. A. (2016) · Stroke · doi:10.1161/strokeaha.115.009955 · Cited by 209
Wang, J., Yarnykh, V. L., & Yuan, C. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22149 · Cited by 188
Intracranial Carotid Artery Atherosclerosis: Prevalence and Risk Factors in the General Population
Bos, D., van der Rijk, M. J. M., Geeraedts, T. E. A., Hofman, A., Krestin, G. P., Witteman, J. C. M., van der Lugt, A., Ikram, M. A., & Vernooij, M. W. (2012) · Stroke · doi:10.1161/strokeaha.111.648667 · Cited by 187
An Image-based Approach to Understanding the Physics of MR Artifacts
Morelli, J. N., Runge, V. M., Ai, F., Attenberger, U., Vu, L., Schmeets, S. H., Nitz, W. R., & Kirsch, J. E. (2011) · RadioGraphics · doi:10.1148/rg.313105115 · Cited by 171
Dieleman, N., van der Kolk, A. G., Zwanenburg, J. J. M., Harteveld, A. A., Biessels, G. J., Luijten, P. R., & Hendrikse, J. (2014) · Circulation · doi:10.1161/circulationaha.113.006919 · Cited by 168 · cited 7×
“Use of Contrast Agents The use of contrast material–enhanced MR imaging is considered a necessary component of VW imaging protocols (1,2).”
BackgroundMethodSelf-citationChen, X. Y., Wong, K. S., Lam, W. W. M., Zhao, H.-L., & Ng, H. K. (2008) · Cerebrovascular Diseases · doi:10.1159/000111525 · Cited by 167
Li, L., Miller, K. L., & Jezzard, P. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24142 · Cited by 153
Tran, T., Sundaram, C. P., Bahler, C. D., Eble, J. N., Grignon, D. J., Monn, M. F., Simper, N. B., & Liang Cheng, C. (2015) · Journal of Cancer · doi:10.7150/jca.12094 · Cited by 150
Intracranial Vessel Wall Imaging at 7.0-T MRI
van der Kolk, A. G., Zwanenburg, J. J. M., Brundel, M., Biessels, G. J., Visser, F., Luijten, P. R., & Hendrikse, J. (2011) · Stroke · doi:10.1161/strokeaha.111.620443 · Cited by 141
Self-citationVisualization of Perivascular Spaces and Perforating Arteries With 7 T Magnetic Resonance Imaging
Bouvy, W. H., Biessels, G. J., Kuijf, H. J., Kappelle, L. J., Luijten, P. R., & Zwanenburg, J. J. M. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000027 · Cited by 140
Self-citationMR Imaging Measures of Intracranial Atherosclerosis in a Population-based Study
Qiao, Y., Güallar, E., Suri, F. K., Liu, L., Zhang, Y., Anwar, Z., Mirbagheri, S., Xie, Y. J., Nezami, N., Intrapiromkul, J., et al. (2016) · Radiology · doi:10.1148/radiol.2016151124 · Cited by 126
Atherosclerosis of middle cerebral artery: Evaluation with high-resolution MR imaging at 3T
Li, M. L., Xu, W., Song, L., Feng, F., You, H., Ni, J., Gao, S., Cui, L., & Jin, Z. (2008) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2008.10.019 · Cited by 124
Vessel Wall Magnetic Resonance Imaging in Acute Ischemic Stroke
Power, S., Matouk, C. C., Casaubon, L. K., Silver, F. L., Krings, T., Mikulis, D. J., & Mandell, D. M. (2014) · Stroke · doi:10.1161/strokeaha.114.005618 · Cited by 112
Arterial remodeling of advanced basilar atherosclerosis: A 3-tesla MRI study
Ma, N., Jiang, W., Lou, X., Ma, L., Du, B., Cai, J., & Zhao, T. (2010) · Neurology · doi:10.1212/wnl.0b013e3181e8e714 · Cited by 109
Mossa‐Basha, M., de Havenon, A., Becker, K. J., Hallam, D. K., Levitt, M. R., Cohen, W. A., Hippe, D. S., Alexander, M. D., Tirschwell, D., Hatsukami, T. S., et al. (2016) · Stroke · doi:10.1161/strokeaha.116.013320 · Cited by 106
Harteveld, A. A., van der Kolk, A. G., van der Worp, H. B., Dieleman, N., Siero, J. C. W., Kuijf, H. J., Frijns, C. J. M., Luijten, P. R., Zwanenburg, J. J. M., & Hendrikse, J. (2016) · European Radiology · doi:10.1007/s00330-016-4483-3 · Cited by 91
Self-citationIntracranial atherosclerosis: Correlation between in-vivo 3T high resolution MRI and pathology
Turan, T. N., Rumboldt, Z., Granholm, A., Columbo, L., Welsh, C. T., Lopes-Virella, M. F., Spampinato, M. V., & Brown, T. R. (2014) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2014.10.007 · Cited by 88
Vos, A., Hecke, W. V., Spliet, W. G. M., Goldschmeding, R., Išgum, I., Kockelkoren, R., Bleys, R. L. A. W., Mali, W. P. T. M., de Jong, P. A., & Vink, A. (2015) · Stroke · doi:10.1161/strokeaha.115.011196 · Cited by 82
van der Kolk, A. G., Zwanenburg, J. J. M., Denswil, N. P., Vink, A., Spliet, W. G. M., Daemen, M. J. A. P., Visser, F., Klomp, D. W. J., Luijten, P. R., & Hendrikse, J. (2014) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4178 · Cited by 81
Self-citationHigh-Resolution MR Imaging of the Cervical Arterial Wall: What the Radiologist Needs to Know
Oppenheim, C., Naggara, O. N., Touzé, E., Lacour, J., Schmitt, E., Bonneville, F., Crozier, S., Guegan-Massardier, E., Gérardin, E., Leclerc, X., et al. (2009) · Radiographics · doi:10.1148/rg.295085183 · Cited by 81
Multi-sequence whole-brain intracranial vessel wall imaging at 7.0 tesla
van der Kolk, A. G., Hendrikse, J., Brundel, M., Biessels, G. J., Smit, E. J., Visser, F., Luijten, P. R., & Zwanenburg, J. J. M. (2013) · European Radiology · doi:10.1007/s00330-013-2905-z · Cited by 78
Self-citationVisualization of the Aneurysm Wall: A 7.0-Tesla Magnetic Resonance Imaging Study
Kleinloog, R., Korkmaz, E., Zwanenburg, J. J. M., Kuijf, H. J., Visser, F., Blankena, R., Post, J. A., Ruigrok, Y. M., Luijten, P. R., Regli, L., et al. (2014) · Neurosurgery · doi:10.1227/neu.0000000000000559 · Cited by 72
Self-citationHigh resolution three dimensional intracranial arterial wall imaging at 3 T using T1 weighted SPACE
Zhang, L., Zhang, N., Wu, J., Zhang, L., Huang, Y., Liu, X., & Chung, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2015.06.006 · Cited by 71
Jiang, Y., Zhu, C., Peng, W., Degnan, A. J., Chen, L., Wang, X., Liu, Q., Wang, Y., Xiang, Z., Teng, Z., et al. (2016) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2016.03.033 · Cited by 68
High-Resolution Postcontrast Time-of-Flight MR Angiography of Intracranial Perforators at 7.0 Tesla
Harteveld, A. A., Cocker, L. J. L. D., Dieleman, N., van der Kolk, A. G., Zwanenburg, J. J. M., Robe, P. A. J. T., Luijten, P. R., & Hendrikse, J. (2015) · PLoS ONE · doi:10.1371/journal.pone.0121051 · Cited by 55
Self-citationHarteveld, A. A., Denswil, N. P., Siero, J. C. W., Zwanenburg, J. J. M., Vink, A., Pouran, B., Spliet, W. G. M., Klomp, D. W. J., Luijten, P. R., Daemen, M. J. A. P., et al. (2015) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4628 · Cited by 53
Self-citationMR imaging for the noninvasive assessment of atherothrombotic plaques
Fayad, Z. A. (2003) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/s1064-9689(02)00023-5 · Cited by 47
Determinants of cerebrovascular remodeling: Do large brain arteries accommodate stenosis?
Gutierrez, J., Goldman, J. E., Honig, L. S., Elkind, M. S. V., Morgello, S., & Marshall, R. S. (2014) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2014.05.925 · Cited by 35
The contribution of HIV infection to intracranial arterial remodeling: A pilot study
Gutierrez, J., Elkind, M. S. V., Petito, C. K., Chung, D. Y., Dwork, A. J., & Marshall, R. S. (2012) · Neuropathology · doi:10.1111/j.1440-1789.2012.01358.x · Cited by 35
Feasibility of high-resolution pituitary MRI at 7.0 tesla
de Rotte, A. A. J., van der Kolk, A. G., Rutgers, D. R., ZELISSEN, P. M. J., Visser, F., Luijten, P. R., & Hendrikse, J. (2014) · European Radiology · doi:10.1007/s00330-014-3230-x · Cited by 31
Self-citationHigh-resolution Magnetic Resonance Imaging of Moyamoya Disease
Yu, L., Zhang, Q., Shi, Z.-Y., Wang, M., & Zhang, D. (2015) · Chinese Medical Journal · doi:10.4103/0366-6999.170257 · Cited by 27
Wang, J., Guan, M., Yamada, K., Hippe, D. S., Kerwin, W. S., Yuan, C., Börnert, P., & Zhao, X. (2016) · PLoS ONE · doi:10.1371/journal.pone.0149130 · Cited by 26
Lee, W. J., Choi, H. S., Jang, J., Sung, J., Kim, T., Koo, J., Shin, Y. S., Jung, S. L., Ahn, K. J., & Kim, B. (2015) · Neuroradiology · doi:10.1007/s00234-015-1566-9 · Cited by 17
Li, B., Li, H., Li, J., Zhang, Y., Wang, X., Zhang, J., Dong, L., & Fang, J. S. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2015.03.009 · Cited by 15
Metadata
- Authors
- Lindenholz, A., van der Kolk, A. G., Zwanenburg, J. J. M., & Hendrikse, J.
- Venue
- Radiology
- Published
- 2018-01
- Volume
- 286
- Issue
- 1
- Pages
- 12-28
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2776026989
- Cited by
- 224
- References
- 53
- FWCI
- 10.60
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.