Subacute and Chronic Left Ventricular Myocardial Scar: Accuracy of Texture Analysis on Nonenhanced Cine MR Images
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Purpose To test whether texture analysis (TA) allows for the diagnosis of subacute and chronic myocardial infarction (MI) on noncontrast material–enhanced cine cardiac magnetic resonance (MR) images. Materials and Methods In this retrospective, institutional review board–approved study, 120 patients who underwent cardiac MR imaging and showed large transmural (volume of enhancement on late gadolinium enhancement [LGE] images >20%, n = 72) or small (enhanced volume ≤20%, n = 48) subacute or chronic ischemic scars were included. Sixty patients with normal cardiac MR imaging findings served as control subjects. Regions of interest for TA encompassing the left ventricle were drawn by two blinded, independent readers on cine images in end systole by using a freely available software package. Stepwise dimension reduction and texture feature selection based on reproducibility, machine learning, and correlation analyses were performed for selecting features, enabling the diagnosis of MI on nonenhanced cine MR images by using LGE imaging as the standard of reference. Results Five independent texture features allowed for differentiation between ischemic scar and normal myocardium on cine MR images in both subgroups: Teta1, Perc.01, Variance, WavEnHH.s-3, and S(5,5)SumEntrp (in patients with large MI: all P values < .001; in patients with small MI: Teta1 and Perc.01, P < .001; Variance, P = .026; WavEnHH.s-3, P = .007; S[5,5]SumEntrp, P = .045). Multiple logistic regression models revealed that combining the features Teta1 and Perc.01 resulted in the highest accuracy for diagnosing large and small MI on cine MR images, with an area under the curve of 0.93 and 0.92, respectively. Conclusion This proof-of-concept study indicates that TA of nonenhanced cine MR images allows for the diagnosis of subacute and chronic MI with high accuracy. © RSNA, 2017 Online supplemental material is available for this article.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Radiomics: Images Are More than Pictures, They Are Data
Gillies, R. J., Kinahan, P. E., & Hricak, H. (2016) · Radiology · doi:10.1148/radiol.2015151169 · Cited by 8,421 · cited 1×
“Two other approaches for feature reduction have been recently suggested: averaging texture features among different directions (16) or using more advanced machine learning algorithms such as neuronal networks or deep learning, leading the path to the field of radiomics (33).”
MethodHeart Disease and Stroke Statistics—2016 Update: A Report From the American Heart Association
Mozaffarian, D., Benjamin, E. J., Go, A. S., Arnett, D. K., Blaha, M. J., Cushman, M., Das, S. R., de Ferranti, S., Després, J.-P., Fullerton, H. J., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000350 · Cited by 6,596 · cited 1×
“Myocardial infarction (MI) causes about one-third of all deaths in the group of patients older than 35 years (1).”
BackgroundLong-term use of ticagrelor in patients with prior myocardial infarction
Bonaca, M. P., Bhatt, D. L., Cohen, M., Steg, P. G., Storey, R. F., Jensen, E. C., Magnani, G., Bansilal, S., Fish, M. P., Im, K., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1500857 · Cited by 1,999 · cited 1×
“Patients with myocardial scar after MI are at increased risk for arrhythmia and death (2), highlighting the relevance of detecting and characterizing myocardial scar to guide intensive secondary prevention (3).”
BackgroundTexture analysis of medical images
Castellano, G., Bonilha, L., Li, L. M., & Cendes, F. (2004) · Clinical Radiology · doi:10.1016/j.crad.2004.07.008 · Cited by 1,026
Jernberg, T., Hasvold, P., Henriksson, M., Hjelm, H., Thuresson, M., & Janzon, M. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehu505 · Cited by 875 · cited 1×
“Patients with myocardial scar after MI are at increased risk for arrhythmia and death (2), highlighting the relevance of detecting and characterizing myocardial scar to guide intensive secondary prevention (3).”
BackgroundMaZda—A software package for image texture analysis
Szczypiński, P. M., Strzelecki, M., Materka, A., & Klepaczko, A. (2009) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2008.08.005 · Cited by 712 · cited 3×
“TA was performed in all 180 patients by a radiologist (B.B., with 5 years of experience in cardiovascular imaging) using a freely available software package (MaZda, version 4.6; Institute of Electronics, Technical University of Lodz, Lodz, Poland) (22) installed on a standard personal computer.”
BackgroundMethodInfluentialCollewet, G., Strzelecki, M., & Mariette, F. (2004) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2003.09.001 · Cited by 518
Amado, L. C., Gerber, B. L., Gupta, S. N., Rettmann, D. W., Szarf, G., Schock, R., Nasir, K., Kraitchman, D. L., & Lima, J. A. C. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.09.020 · Cited by 508
Ng, F., Ganeshan, B., Kozarski, R., Miles, K. A., & Goh, V. (2013) · Radiology · doi:10.1148/radiol.12120254 · Cited by 432
Collidge, T. A., Thomson, P. C., Mark, P. B., Traynor, J. P., Jardine, A. G., Morris, S. T. W., Simpson, K., & Roditi, G. H. (2007) · Radiology · doi:10.1148/radiol.2451070353 · Cited by 319
Hodgdon, T., McInnes, M. D. F., Schieda, N., Flood, T. A., Lamb, L., & Thornhill, R. E. (2015) · Radiology · doi:10.1148/radiol.2015142215 · Cited by 261
Breast Cancer Heterogeneity: MR Imaging Texture Analysis and Survival Outcomes
Kim, J., Ko, E. S., Lim, Y., Lee, K. S., Han, B., Ko, E. Y., Hahn, S. Y., & Nam, S. J. (2016) · Radiology · doi:10.1148/radiol.2016160261 · Cited by 253
Three-dimensional solid texture analysis in biomedical imaging: Review and opportunities
Depeursinge, A., Foncubierta-Rodriguez, A., Van De Ville, D., & Müller, H. (2014) · Medical Image Analysis · doi:10.1016/j.media.2013.10.005 · Cited by 244
Journey toward Computer-aided Diagnosis: Role of Image Texture Analysis
Tourassi, G. D. (1999) · Radiology · doi:10.1148/radiology.213.2.r99nv49317 · Cited by 233
Khan, J. N., Singh, A., Nazir, S. A., Kanagala, P., Gershlick, A., & McCann, G. P. (2015) · European Journal of Radiology · doi:10.1016/j.ejrad.2015.02.002 · Cited by 137
MR Imaging of Myocardial Infarction
Rajiah, P. S., Desai, M. Y., Kwon, D. H., & Flamm, S. D. (2013) · Radiographics · doi:10.1148/rg.335125722 · Cited by 134 · cited 1×
“Previous studies reporting on regional myocardial lipomatous metaplasia leading to chemical shift artifacts (29), wall thinning, and/ or wall motion abnormalities in regions of myocardial scar (30) suggested that it might be feasible to depict ischemic scars on cine MR images alone.”
BackgroundHeidary, S., Patel, H., Chung, J., Yokota, H., Gupta, S., Bennett, M. V., Katikireddy, C. K., Nguyen, P. K. P., Pauly, J. M., Terashima, M., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.01.052 · Cited by 131
Texture analysis methodologies for magnetic resonance imaging
Materka, A. (2004) · Dialogues in Clinical Neuroscience · doi:10.31887/dcns.2004.6.2/amaterka · Cited by 129 · cited 1×
“The local subpattern properties give rise to the perceived lightness, uniformity, density, roughness, regularity, linearity, and many other properties of the texture as a whole (21).”
BackgroundTiwari, P., Prasanna, P., Wolansky, L., Pinho, M., Cohen, M., Nayate, A. P., Gupta, A., Singh, G., Hatanpaa, K. J., Sloan, A., et al. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4931 · Cited by 122
Texture Analysis in Magnetic Resonance Imaging: Review and Considerations for Future Applications
Larroza, A., Bodí, V., & Moratal, D. (2016) · InTech eBooks · doi:10.5772/64641 · Cited by 118
Depeursinge, A., Chin, A. S.-L., Leung, A. N. C., Terrone, D. G., Bristow, M., Rosen, G., & Rubin, D. L. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000127 · Cited by 92
Goetti, R. P., Kozerke, S., Donati, O. F., Sürder, D., Stolzmann, P., Kaufmann, P. A., Lüscher, T. F., Corti, R., & Manka, R. (2011) · Radiology · doi:10.1148/radiol.11102216 · Cited by 75
Self-citationMax-AUC Feature Selection in Computer-Aided Detection of Polyps in CT Colonography
Xu, J., & Suzuki, K. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2278023 · Cited by 46
Cardiovascular magnetic resonance imaging in ischemic heart disease
von Knobelsdorff‐Brenkenhoff, F., & Schulz‐Menger, J. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23580 · Cited by 37 · cited 1×
“Late gadolinium enhancement (LGE) cardiac magnetic resonance (MR) imaging is a clinically established and accurate method for the assessment of ischemic myocardial scar (4,5).”
MethodMRI texture analysis of subchondral bone at the tibial plateau
Mackay, J., Murray, P. J., Kasmai, B., Johnson, G., Donell, S. T., & Toms, A. P. (2015) · European Radiology · doi:10.1007/s00330-015-4142-0 · Cited by 37 · cited 3×
“Two other approaches for feature reduction have been recently suggested: averaging texture features among different directions (16) or using more advanced machine learning algorithms such as neuronal networks or deep learning, leading the path to the field of radiomics (33).”
BackgroundMethodAbdel‐Nasser, M., Melendez, J., Moreno, A., & Puig, D. (2016) · International Journal of Optics · doi:10.1155/2016/1370259 · Cited by 23
Anorexia Nervosa: Analysis of Trabecular Texture with CT
Tabari, A., Torriani, M., Miller, K. K., Klibanski, A., Kalra, M. K., & Bredella, M. A. (2016) · Radiology · doi:10.1148/radiol.2016160970 · Cited by 21
A Deceiving Charm of Feature Selection: The Microarray Case Study
Kursa, M. B., & Rudnicki, W. R. (2011) · Advances in intelligent and soft computing · doi:10.1007/978-3-642-23169-8_16 · Cited by 13 · cited 4×
“Figure E1 (online) shows the graphical output of the Boruta-based feature selection process.”
MethodInfluential
Cited by
Radiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
Self-citationMachine learning in cardiovascular magnetic resonance: basic concepts and applications
Leiner, T., Rueckert, D., Suinesiaputra, A., Baeßler, B., Nezafat, R., Išgum, I., & Young, A. A. (2019) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-019-0575-y · Cited by 282
Image-Based Cardiac Diagnosis With Machine Learning: A Review
Martin-Isla, C., Campello, V. M., Izquierdo, C., Raisi-Estabragh, Z., Baeßler, B., Petersen, S. E., & Lekadir, K. (2020) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2020.00001 · Cited by 248
Robustness and Reproducibility of Radiomics in Magnetic Resonance Imaging: A Phantom Study
Baeßler, B., Weiss, K., & Pinto dos Santos, D. (2019) · Investigative Radiology · doi:10.1097/rli.0000000000000530 · Cited by 229
Li, Z.-C., Bai, H., Sun, Q., Li, Q., Liu, L., Zou, Y., Chen, Y., Liang, C., & Zheng, H. (2018) · European Radiology · doi:10.1007/s00330-017-5302-1 · Cited by 158
Metadata
- Authors
- Baessler, B., Mannil, M., Oebel, S., Maintz, D., Alkadhi, H., & Manka, R.
- Venue
- Radiology
- Published
- 2018-01
- Volume
- 286
- Issue
- 1
- Pages
- 103-112
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2747206966
- Cited by
- 202
- References
- 28
- FWCI
- 12.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.