The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Can Quantitative CT Texture Analysis be Used to Differentiate Fat-poor Renal Angiomyolipoma from Renal Cell Carcinoma on Unenhanced CT Images?
Abstract
PURPOSE: To determine the accuracy of texture analysis to differentiate fat-poor angiomyolipoma (fp-AML) from renal cell carcinoma (RCC) on unenhanced computed tomography (CT) images. MATERIALS AND METHODS: In this institutional review board-approved retrospective case-control study, patients with AML and RCC were identified from the pathology database: there were 16 patients with fp-AML (no visible fat at unenhanced CT) and 84 patients with RCC. Axial unenhanced CT images were contoured manually by two independent analysts. Texture analysis was performed for each lesion, and reproducibility was assessed. Texture features related to the gray-level histogram, gray-level co-occurrence, and run-length matrix statistics were evaluated. The most discriminative features were used to generate support vector machine (SVM) classifiers. Diagnostic accuracy of textural features was assessed and 10-fold cross validation was performed. Unenhanced CT images for each patient were independently reviewed by two blinded radiologists who subjectively graded lesion heterogeneity on a five-point scale. Differences in area under the receiver operating characteristic curve (AUC) between subjective heterogeneity ratings and textural features were evaluated by using the DeLong method. RESULTS: There was lower lesion homogeneity and higher lesion entropy in RCCs (P ≤ .01). A model incorporating several texture features resulted in an AUC of 0.89 ± 0.04. The average SVM accuracy of textural features ranged from 83% to 91% (after 10-fold cross validation). An optimal subjective heterogeneity rating of 2 or higher was identified as a predictor of RCC for both readers, with no significant difference in AUC between readers (P = .06). Each of the three textural-based classifiers was more accurate than either radiologists' subjective heterogeneity ratings for the models incorporating a subset of the top three textural features (difference in AUC between textural features and subjective visual heterogeneity, 0.25; 95% confidence interval: 0.02, 0.47; P = .03). CONCLUSION: CT texture analysis can be used to accurately differentiate fp-AML from RCC on unenhanced CT images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526
Texture analysis using gray level run lengths
Galloway, M. M. (1975) · Computer Graphics and Image Processing · doi:10.1016/s0146-664x(75)80008-6 · Cited by 2,141
Collewet, G., Strzelecki, M., & Mariette, F. (2004) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2003.09.001 · Cited by 518
Ganeshan, B., Panayiotou, E., Burnand, K., Dizdarevic, S., & Miles, K. (2012) · European Radiology · doi:10.1007/s00330-011-2319-8 · Cited by 505
Non–Small Cell Lung Cancer: Histopathologic Correlates for Texture Parameters at CT
Ganeshan, B., Goh, V., Mandeville, H. C., Ng, Q. S., Hoskin, P. J., & Miles, K. A. (2013) · Radiology · doi:10.1148/radiol.12112428 · Cited by 447
Texture Analysis: A Review of Neurologic MR Imaging Applications
Kassner, A., & Thornhill, R. E. (2010) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2061 · Cited by 408
Self-citationGoh, V., Ganeshan, B., Nathan, P., Juttla, J. K., Vinayan, A., & Miles, K. A. (2011) · Radiology · doi:10.1148/radiol.11110264 · Cited by 367
Cited by
STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration
Cohen, J. F., Korevaar, D. A., Altman, D. G., Bruns, D. E., Gatsonis, C. A., Hooft, L., Irwig, L., Levine, D., Reitsma, J. B., de Vet, H. C. W., et al. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-012799 · Cited by 2,570
CT Texture Analysis: Definitions, Applications, Biologic Correlates, and Challenges
Lubner, M. G., Smith, A. D., Sandrasegaran, K., Sahani, D. V., & Pickhardt, P. J. (2017) · RadioGraphics · doi:10.1148/rg.2017170056 · Cited by 773
Radiomics with artificial intelligence: a practical guide for beginners
Department of Radiology Istanbul Training and Research Hospital, I., Kocak, B., Durmaz, E. S., Department of Radiology, B. M. S. S. H., Ates, E., Department of Radiology Istanbul Training and Research Hospital, I., Kilickesmez, O., & Department of Radiology Istanbul Training and Research Hospital, I. (2019) · Diagnostic and Interventional Radiology · doi:10.5152/dir.2019.19321 · Cited by 366
Yi, X., Guan, X., Chen, C., Zhang, Y., Zhang, Z., Li, M., Liu, P., Yu, A., Long, X., Liu, L., et al. (2018) · Journal of Cancer · doi:10.7150/jca.26356 · Cited by 87
Ho, L. M., Samei, E., Mazurowski, M. A., Zheng, Y., Allen, B. C., Nelson, R. C., & Marin, D. (2019) · American Journal of Roentgenology · doi:10.2214/ajr.18.20097 · Cited by 65
Metadata
- Authors
- Hodgdon, T., McInnes, M. D. F., Schieda, N., Flood, T. A., Lamb, L., & Thornhill, R. E.
- Venue
- Radiology
- Published
- 2015-09
- Volume
- 276
- Issue
- 3
- Pages
- 787-796
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1987151740
- Cited by
- 261
- References
- 21
- FWCI
- 20.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Can Quantitative CT Texture Analysis be Used to Differentiate Fat-poor Renal Angiomyolipoma from Renal Cell Carcinoma on Unenhanced CT Images? https://app.cochat.ai/papers/10.1148/radiol.2015142215
- The paper
- Hodgdon, T., McInnes, M. D. F., Schieda, N., Flood, T. A., Lamb, L., & Thornhill, R. E. (2015). Can Quantitative CT Texture Analysis be Used to Differentiate Fat-poor Renal Angiomyolipoma from Renal Cell Carcinoma on Unenhanced CT Images? Radiology. https://doi.org/10.1148/radiol.2015142215
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.