CoChat

Deep Learning for Diagnosis of Chronic Myocardial Infarction on Nonenhanced Cardiac Cine MRI

Open access
Zhang, Nan, Yang, Guang, Gao, Zhifan, Xu, Chenchu, Zhang, Yanping, Shi, Rui, Keegan, Jennifer, Xu, Lei, Zhang, Heye, Fan, Zhanming, Firmin, David · 2019 · Radiology
Cited by 231

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background Renal impairment is common in patients with coronary artery disease and, if severe, late gadolinium enhancement (LGE) imaging for myocardial infarction (MI) evaluation cannot be performed. Purpose To develop a fully automatic framework for chronic MI delineation via deep learning on non–contrast material–enhanced cardiac cine MRI. Materials and Methods In this retrospective single-center study, a deep learning model was developed to extract motion features from the left ventricle and delineate MI regions on nonenhanced cardiac cine MRI collected between October 2015 and March 2017. Patients with chronic MI, as well as healthy control patients, had both nonenhanced cardiac cine (25 phases per cardiac cycle) and LGE MRI examinations. Eighty percent of MRI examinations were used for the training data set and 20% for the independent testing data set. Chronic MI regions on LGE MRI were defined as ground truth. Diagnostic performance was assessed by analysis of the area under the receiver operating characteristic curve (AUC). MI area and MI area percentage from nonenhanced cardiac cine and LGE MRI were compared by using the Pearson correlation, paired t test, and Bland-Altman analysis. Results Study participants included 212 patients with chronic MI (men, 171; age, 57.2 years ± 12.5) and 87 healthy control patients (men, 42; age, 43.3 years ± 15.5). Using the full cardiac cine MRI, the per-segment sensitivity and specificity for detecting chronic MI in the independent test set was 89.8% and 99.1%, respectively, with an AUC of 0.94. There were no differences between nonenhanced cardiac cine and LGE MRI analyses in number of MI segments (114 vs 127, respectively; P = .38), per-patient MI area (6.2 cm2 ± 2.8 vs 5.5 cm2 ± 2.3, respectively; P = .27; correlation coefficient, r = 0.88), and MI area percentage (21.5% ± 17.3 vs 18.5% ± 15.4; P = .17; correlation coefficient, r = 0.89). Conclusion The proposed deep learning framework on nonenhanced cardiac cine MRI enables the confirmation (presence), detection (position), and delineation (transmurality and size) of chronic myocardial infarction. However, future larger-scale multicenter studies are required for a full validation. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Leiner in this issue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2019182304

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 231

Metadata

Authors
Zhang, N., Yang, G., Gao, Z., Xu, C., Zhang, Y., Shi, R., Keegan, J., Xu, L., Zhang, H., Fan, Z., & Firmin, D.
Venue
Radiology
Published
2019-06
Volume
291
Issue
3
Pages
606-617
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2942777796
Cited by
231
References
5
FWCI
18.30
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Deep Learning for Diagnosis of Chronic Myocardial Infarction on Nonenhanced Cardiac Cine MRI. https://app.cochat.ai/papers/10.1148/radiol.2019182304
The paper
Zhang, N., Yang, G., Gao, Z., Xu, C., Zhang, Y., Shi, R., Keegan, J., Xu, L., Zhang, H., Fan, Z., & Firmin, D. (2019). Deep Learning for Diagnosis of Chronic Myocardial Infarction on Nonenhanced Cardiac Cine MRI. Radiology. https://doi.org/10.1148/radiol.2019182304

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.