Digital Mammography versus Digital Mammography Plus Tomosynthesis in Breast Cancer Screening: The Oslo Tomosynthesis Screening Trial
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Background Digital breast tomosynthesis (DBT) is replacing digital mammography (DM) in the clinical workflow. Currently, there are limited prospective studies comparing the diagnostic accuracy of both examinations and the role of synthetic mammography (SM) and computer-aided detection (CAD). Purpose To compare the accuracy of DM versus DM + DBT in population-based breast cancer screening. Materials and Methods This prospective study, performed from November 2010 to December 2012, included 24 301 women (mean age, 59.1 years ± 5.7 [standard deviation]) with 281 cancers, of which 51 were interval cancers. Each examination was independently interpreted with four reading modes: DM, DM + CAD, DM + DBT, and SM + DBT. Sensitivity and specificity were compared for DM versus DM + DBT, DM versus DM + CAD, DM + DBT versus SM + DBT, and DM versus DM + DBT at double reading. Reader-adjusted performance characteristics of reading modes were evaluated on the basis of pre-arbitration (initial interpretation) scores. Statistical analysis was based on cluster bootstrap analysis using 10 000 random resamples. Results Sensitivity was 54.1% (152 of 281) for DM and 70.5% (198 of 281) for DM + DBT. Reader-adjusted difference was 12.6% (95% confidence interval [CI]: 5.2%, 19.7%; P = .001). Specificity was 94.2% (false-positive fraction [FPF], 5.8%; 1388 of 24 020) for DM and 95.0% (FPF, 5.0%; 1209/24 020) for DM + DBT, with a reader-adjusted difference in FPF of -1.2% (95% CI: -1.7%, -0.7%; P < .001). Sensitivity was 69.0% (194 of 281) for SM + DBT and 70.5% (198 of 281) for DM + DBT, with a reader-adjusted difference of 1.0% (95% CI: -6.2%, 8.5%; P = .77). Specificity was 95.4% (FPF, 4.6%; 1111 of 24 020) for SM + DBT and 95.0% (FPF, 5.0%;1209 of 24 020) for DM + DBT, with reader-adjusted 95% CIs for FPF of 4.7%, 5.4% and 5.0%, 5.7%, respectively, and a difference of -0.3% (95% CI: -0.8%, 0.2%; P = .23). Differences in sensitivity and specificity with the addition of CAD were small and not significant (P > .2). Conclusion Addition of digital breast tomosynthesis to digital mammography resulted in significant gains in sensitivity and specificity. Synthetic mammography in combination with digital breast tomosynthesis had similar sensitivity and specificity to digital mammography in combination with digital breast tomosynthesis. © RSNA, 2019 See also the editorial by Lång in this issue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Skaane, P., Bandos, A. I., Gullien, R., Eben, E. B., Ekseth, U., Haakenaasen, U., Izadi, M., Jebsen, I. N., Jahr, G., Krager, M., et al. (2013) · Radiology · doi:10.1148/radiol.12121373 · Cited by 1,012
Self-citationBreast Cancer Screening Using Tomosynthesis in Combination With Digital Mammography
Friedewald, S. M., Rafferty, E. A., Rose, S. L., Durand, M. A., Plecha, D. M., Greenberg, J. S., Hayes, M. K., Copit, D. S., Carlson, K. L., Cink, T. M., et al. (2014) · JAMA · doi:10.1001/jama.2014.6095 · Cited by 851
Ciatto, S., Houssami, N., Bernardi, D., Caumo, F., Pellegrini, M., Brunelli, S., Tuttobene, P., Bricolo, P., Fantò, C., Valentini, M., et al. (2013) · The Lancet Oncology · doi:10.1016/s1470-2045(13)70134-7 · Cited by 838
Tabár, L., Vitak, B., Chen, T. H.-H., Yen, A. M.-F., Cohen, A., Tot, T., Chiu, S. Y.-H., Chen, S. L.-S., Fann, J. C.-Y., Rosell, J., et al. (2011) · Radiology · doi:10.1148/radiol.11110469 · Cited by 791
Diagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678
Field, C. A., & Welsh, A. H. (2007) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.1467-9868.2007.00593.x · Cited by 426
Skaane, P., Bandos, A. I., Eben, E. B., Jebsen, I. N., Krager, M., Haakenaasen, U., Ekseth, U., Izadi, M., Hofvind, S., & Gullien, R. (2014) · Radiology · doi:10.1148/radiol.13131391 · Cited by 332
Self-citationSingle Reading with Computer-Aided Detection for Screening Mammography
Gilbert, F. J., Astley, S. M., Gillan, M. G. C., Agbaje, O. F., Wallis, M. G., James, J., Boggis, C. R. M., & Duffy, S. W. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0803545 · Cited by 296
Bernardi, D., Macaskill, P., Pellegrini, M., Valentini, M., Fantò, C., Ostillio, L., Tuttobene, P., Luparia, A., & Houssami, N. (2016) · The Lancet Oncology · doi:10.1016/s1470-2045(16)30101-2 · Cited by 275
Bustreo, S., Osella-Abate, S., Cassoni, P., Donadio, M., Airoldi, M., Pedani, F., Papotti, M., Sapino, A., & Castellano, I. (2016) · Breast Cancer Research and Treatment · doi:10.1007/s10549-016-3817-9 · Cited by 229
Cited by
Zhou, Y., Chen, H., Li, Y., Liu, Q., Xu, X., Wang, S., Yap, P.-T., & Shen, D. (2021) · Medical Image Analysis · doi:10.1016/j.media.2020.101918 · Cited by 352
Metadata
- Authors
- Skaane, P., Bandos, A. I., Niklason, L. T., Sebuødegård, S., Østerås, B. H., Gullien, R., Gur, D., & Hofvind, S.
- Venue
- Radiology
- Published
- 2019-04
- Volume
- 291
- Issue
- 1
- Pages
- 23-30
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2915507740
- Cited by
- 171
- References
- 14
- FWCI
- 17.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.