Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 332

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Two-View Digital Breast Tomosynthesis Screening with Synthetically Reconstructed Projection Images: Comparison with Digital Breast Tomosynthesis with Full-Field Digital Mammographic Images

Skaane, Per, Bandos, Andriy I., Eben, Ellen B., Jebsen, Ingvild N., Krager, Mona, Haakenaasen, Unni, Ekseth, Ulrika, Izadi, Mina, Hofvind, Solveig, Gullien, Randi·2014·Radiology

Abstract

PURPOSE: To compare the performance of two versions of reconstructed two-dimensional (2D) images in combination with digital breast tomosynthesis (DBT) versus the performance of standard full-field digital mammography (FFDM) plus DBT. MATERIALS AND METHODS: This trial had ethical committee approval, and all participants gave written informed consent. Examinations (n = 24 901) in women between the ages of 50 and 69 years (mean age, 59.2 years) were interpreted prospectively as part of a screening trial that included independent interpretations of FFDM plus DBT and reconstructed 2D images plus DBT. Reconstructed 2D images do not require radiation exposure. Using analyses for binary data that accounted for correlated interpretations and were adjusted for reader-specific volume, two versions (initial and current) of reconstructed 2D images used during trial periods 1 (from November 22, 2010, to December 21, 2011; 12 631 women) and 2 (from January 20, 2012, to December 19, 2012; 12 270 women) were compared in terms of cancer detection and false-positive rates with the corresponding FFDM plus DBT interpretations. RESULTS: Cancer detection rates were 8.0, 7.4, 7.8, and 7.7 per 1000 screening examinations for FFDM plus DBT in period 1, initial reconstructed 2D images plus DBT in period 1, FFDM plus DBT in period 2, and current reconstructed 2D images plus DBT in period 2, respectively. False-positive scores were 5.3%, 4.6%, 4.6%, and 4.5%, respectively. Corresponding reader-adjusted paired comparisons of false-positive scores revealed significant differences for period 1 (P = .012) but not for period 2 (ratio = 0.99; 95% confidence interval: 0.88, 1.11; P = .85). CONCLUSION: The combination of current reconstructed 2D images and DBT performed comparably to FFDM plus DBT and is adequate for routine clinical use when interpreting screening mammograms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.13131391

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 332

Metadata

Authors
Skaane, P., Bandos, A. I., Eben, E. B., Jebsen, I. N., Krager, M., Haakenaasen, U., Ekseth, U., Izadi, M., Hofvind, S., & Gullien, R.
Venue
Radiology
Published
2014-06
Volume
271
Issue
3
Pages
655-663
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2139442654
Cited by
332
References
9
FWCI
36.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Two-View Digital Breast Tomosynthesis Screening with Synthetically Reconstructed Projection Images: Comparison with Digital Breast Tomosynthesis with Full-Field Digital Mammographic Images. https://app.cochat.ai/papers/10.1148/radiol.13131391
The paper
Skaane, P., Bandos, A. I., Eben, E. B., Jebsen, I. N., Krager, M., Haakenaasen, U., Ekseth, U., Izadi, M., Hofvind, S., & Gullien, R. (2014). Two-View Digital Breast Tomosynthesis Screening with Synthetically Reconstructed Projection Images: Comparison with Digital Breast Tomosynthesis with Full-Field Digital Mammographic Images. Radiology. https://doi.org/10.1148/radiol.13131391

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.