The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Reproducibility of CT Radiomic Features within the Same Patient: Influence of Radiation Dose and CT Reconstruction Settings
Open accessAbstract
Background Results of recent phantom studies show that variation in CT acquisition parameters and reconstruction techniques may make radiomic features largely nonreproduceable and of limited use for prognostic clinical studies. Purpose To investigate the effect of CT radiation dose and reconstruction settings on the reproducibility of radiomic features, as well as to identify correction factors for mitigating these sources of variability. Materials and Methods This was a secondary analysis of a prospective study of metastatic liver lesions in patients who underwent staging with single-energy dual-source contrast material–enhanced staging CT between September 2011 and April 2012. Technique parameters were altered, resulting in 28 CT data sets per patient that included different dose levels, section thicknesses, kernels, and reconstruction algorithm settings. By using a training data set (n = 76), reproducible intensity, shape, and texture radiomic features (reproducibility threshold, R2 ≥ 0.95) were selected and correction factors were calculated by using a linear model to convert each radiomic feature to its estimated value in a reference technique. By using a test data set (n = 75), the reproducibility of hierarchical clustering based on 106 radiomic features measured with different CT techniques was assessed. Results Data in 78 patients (mean age, 60 years ± 10; 33 women) with 151 liver lesions were included. The percentage of radiomic features deemed reproducible for any variation of the different technical parameters was 11% (12 of 106). Of all technical parameters, reconstructed section thickness had the largest impact on the reproducibility of radiomic features (12.3% [13 of 106]) if only one technical parameter was changed while all other technical parameters were kept constant. The results of the hierarchical cluster analysis showed improved clustering reproducibility when reproducible radiomic features with dedicated correction factors were used (ρ = 0.39–0.71 vs ρ = 0.14–0.47). Conclusion Most radiomic features are highly affected by CT acquisition and reconstruction settings, to the point of being nonreproducible. Selecting reproducible radiomic features along with study-specific correction factors offers improved clustering reproducibility. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Sosna in this issue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“However, radiomic features are highly sensitive to CT acquisition and reconstruction parameters; features identified as strongly predictive in one scanner environment or protocol may not generalise to another.3839”
From Prognostication and clinical opportunities with AI for coronary artery calcium: a scoping review (2026) · cites this paper as [38]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular portraits of human breast tumours
Perou, C., Sørlie, T., Eisen, M., van de Rijn, M., Jeffrey, S., Rees, C. A., Pollack, J., Ross, D., Johnsen, H., Akslen, L., et al. (2000) · Nature · doi:10.1038/35021093 · Cited by 16,551
Cluster analysis and display of genome-wide expression patterns
Eisen, M. B., Spellman, P. T., Brown, P. O., & Botstein, D. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.25.14863 · Cited by 16,184
Nishimura, R., Osako, T., Nishiyama, Y., Tashima, R., Nakano, M., Fujisue, M., Toyozumi, Y., & Arima, N. (2013) · Oncology · doi:10.1159/000353099 · Cited by 13,239
Radiomics: Images Are More than Pictures, They Are Data
Gillies, R. J., Kinahan, P. E., & Hricak, H. (2016) · Radiology · doi:10.1148/radiol.2015151169 · Cited by 8,421
Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132
Ki67 expression in breast cancer
Elkablawy, M. A., Albasri, A. M., Mohammed, R. A., Hussainy, A. S., Nouh, M. M., & Alhujaily, A. S. (2016) · Saudi Medical Journal · doi:10.15537/smj.2016.2.12285 · Cited by 4,382
dendextend: an R package for visualizing, adjusting and comparing trees of hierarchical clustering
Galili, T. (2015) · Bioinformatics · doi:10.1093/bioinformatics/btv428 · Cited by 1,826
Huang, Y., Liang, C., He, L., Tian, J., Liang, C., Chen, X., Ma, Z., & Liu, Z. (2016) · Journal of Clinical Oncology · doi:10.1200/jco.2015.65.9128 · Cited by 1,753
Choi, H., Charnsangavej, C., Faria, S., Macapinlac, H., Burgess, M., Patel, S. R., Chen, L. L., Podoloff, D., & Benjamin, R. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.07.3049 · Cited by 1,508
Sun, R., Limkin, E. J., Vakalopoulou, M., Dercle, L., Champiat, S., Han, S. R., Verlingue, L., Brandao, D., Lancia, A., Ammari, S., et al. (2018) · The Lancet Oncology · doi:10.1016/s1470-2045(18)30413-3 · Cited by 1,236
Flagged first, then by citations
Research works printed but not linked: 4
- Robins M, 2018, Proceedings of SPIE: medical imaging 2018—physics of medical imaging. Vol 10573, 105733W
- Midya A, 2018, J Med Imaging (Bellingham), 5, 011020
- R Development Core Team. R, 2010, A language and environment for statistical computing
- Hatt M, 2018, J Nucl Med, 59, 287
Cited by
Sorted by citations
Items 101–200 of 256
Chen, Q., Cui, Y., Xue, T., Peng, H., Li, M., Zhu, X., Duan, S., Gu, H., & Feng, F. (2022) · Abdominal Radiology · doi:10.1007/s00261-022-03620-3 · Cited by 14
Ibrahim, A., Lu, L., Yang, H., Akın, O., Schwartz, L. H., & Zhao, B. (2022) · Applied Sciences · doi:10.3390/app12199824 · Cited by 14
Huang, J., Chen, G., Liu, H., Jiang, W., Mai, S., Zhang, L., Zeng, H., Wu, S., Chen, C. Y., & Wu, Z. (2023) · European Radiology · doi:10.1007/s00330-023-10137-w · Cited by 14
Zhou, C., Zhou, J., Lv, Y., Batuer, M., Huang, J., Zhong, J., Zhong, H., & Qin, G. (2025) · European Journal of Radiology · doi:10.1016/j.ejrad.2025.111956 · Cited by 14
HeLLePhant: A phantom mimicking non-small cell lung cancer for texture analysis in CT images
Rinaldi, L. M., Pezzotta, F., Santaniello, T., Marco, P. D., Bianchini, L., Origgi, D., Cremonesi, M., Milani, P., Mariani, M., & Botta, F. (2022) · Physica Medica · doi:10.1016/j.ejmp.2022.03.010 · Cited by 14
A tri-modal tissue-equivalent anthropomorphic phantom for PET, CT and multi-parametric MRI radiomics
Gallivanone, F., D’Ambrosio, D., Carne, I., D'Arcangelo, M., Montagna, P., Giroletti, E., Poggi, P., Vellani, C., Moro, L., & Castiglioni, I. (2022) · Physica Medica · doi:10.1016/j.ejmp.2022.04.007 · Cited by 14
Welch, M. L., McIntosh, C., Traverso, A., Wee, L., Purdie, T. G., Dekker, A. L. A. J., Haibe‐Kains, B., & Jaffray, D. A. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab63ba · Cited by 15
Hu, S., Lyu, X., Li, W., Cui, X., Liu, Q., Xu, X., Wang, J., Chen, L., Zhang, X., & Yin, Y. (2022) · Contrast Media & Molecular Imaging · doi:10.1155/2022/7693631 · Cited by 13
Wang, Q., Xu, S., Zhang, G., Zhang, X., Gu, J., Yang, S., Zeng, M., & Zhang, Z. (2022) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.13759 · Cited by 12
Zhang, S., Liu, X., Zhou, L., Wang, K., Shao, J., Shi, J., Wang, X., Mu, J., Gao, T., Jiang, Z., et al. (2023) · EClinicalMedicine · doi:10.1016/j.eclinm.2023.102270 · Cited by 13
Radiogenomics in brain, breast, and lung cancer: opportunities and challenges
Singh, A., Chitalia, R., & Despina Kontos, B. (2021) · Journal of medical imaging · doi:10.1117/1.jmi.8.3.031907 · Cited by 13
Identifying Robust Radiomics Features for Lung Cancer by Using In-Vivo and Phantom Lung Lesions
Lu, L., Sun, S. H., Afran, A., Yang, H., Lu, Z. F., So, J. C., Schwartz, L. H., & Zhao, B. (2021) · Tomography · doi:10.3390/tomography7010005 · Cited by 13
Zhang, M. H., Hasse, A., Carroll, T. J., Pearson, A. T., Cipriani, N. A., & Ginat, D. T. (2021) · Gland Surgery · doi:10.21037/gs-20-830 · Cited by 13
Caruso, D., Zerunian, M., Pucciarelli, F., Bracci, B., Polici, M., D’Arrigo, B., Polidori, T., Guido, G., Barbato, L., Polverari, D., et al. (2021) · Diagnostics · doi:10.3390/diagnostics11061000 · Cited by 13
Jahanshahi, A., Soleymani, Y., Ghaziyani, M. F., & Khezerloo, D. (2023) · The Egyptian Journal of Radiology and Nuclear Medicine · doi:10.1186/s43055-023-01029-6 · Cited by 12
Zhang, H., Lu, T., Wang, L., Xing, Y., Hu, Y., Xu, Z., Lu, J. A., Yang, J., Chu, J., Zhang, B., et al. (2025) · European Radiology · doi:10.1007/s00330-025-11374-x · Cited by 12
Reproducibility of radiomic features in SENSE and compressed SENSE: impact of acceleration factors
Kim, M., Jung, S. C., Park, J. E., Park, S. Y., Lee, H., & Choi, K. M. (2021) · European Radiology · doi:10.1007/s00330-021-07760-w · Cited by 12
Choi, W., Dahiya, N., & Nadeem, S. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-16443-9_2 · Cited by 12
Zhong, J., Wu, Z., Wang, L., Chen, Y., Xia, Y., Wang, L., Li, J., Lu, W., Shi, X., Feng, J., et al. (2024) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-023-00901-1 · Cited by 12
Yang, Z. J., Jiang, H., Shan, S., Wang, X., Kou, Q., Wang, C., Jin, P., Xu, Y., Liu, X., Zhang, Y., et al. (2025) · Academic Radiology · doi:10.1016/j.acra.2025.06.056 · Cited by 12
Fujita, S., Hagiwara, A., Yasaka, K., Akai, H., Kunimatsu, A., Kiryu, S., Fukunaga, I., Kato, S., Akashi, T., Kamagata, K., et al. (2022) · European Radiology · doi:10.1007/s00330-022-08555-3 · Cited by 11
Lee, S. B., Hong, Y., Cho, Y. J., Jeong, D., Lee, J., Choi, J. W., Hwang, J., Lee, S., Choi, Y. H., & Cheon, J. (2024) · Bioengineering · doi:10.3390/bioengineering11121212 · Cited by 11
Pacella, G., Brunese, M. C., D’Imperio, E., Rotondo, M., Scacchi, A., Carbone, M., & Guerra, G. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12237380 · Cited by 10
Repeatability, robustness, and reproducibility of texture features on 3 Tesla liver MRI
Prabhu, V., Gillingham, N., Babb, J. S., Mali, R. D., Rusinek, H., Bruno, M. T., & Chandarana, H. (2022) · Clinical Imaging · doi:10.1016/j.clinimag.2022.01.002 · Cited by 10
Kolossváry, M., Bluemke, D. A., Fishman, E. K., Gerstenblith, G., Celentano, D. D., Mandler, R. N., Khalsa, J. H., Bhatia, S., Chen, S., Lai, S., et al. (2022) · European Radiology · doi:10.1007/s00330-022-08894-1 · Cited by 10
Badr, E. (2021) · ACM Computing Surveys · doi:10.1145/3453657 · Cited by 11
Tu, S., Chen, W.-Y., & Wu, C. (2021) · European Radiology · doi:10.1007/s00330-021-07943-5 · Cited by 7
Radiomic Feature Stability Analysis Based on Probabilistic Segmentations
Haarburger, C., Schock, J., Truhn, D., Weitz, P., Müller‐Franzes, G. A., Weninger, L., & Merhof, D. (2020) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi45749.2020.9098674 · Cited by 9
Xue, C., Zhou, Y., Lo, G. G., Wong, O. L., Yu, S. K., Cheung, K. Y., & Yuan, J. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28650 · Cited by 9
Fewer Reproducible Radiomic Features Mean Better Reproducibility within the Same Patient
Sosna, J. (2019) · Radiology · doi:10.1148/radiol.2019191958 · Cited by 9
ICNoduleNet: Enhancing Pulmonary Nodule Detection Performance on Sharp Kernel CT Imaging
Lan, T., Zeng, F., Zhang, Y., Xu, X., & Zhu, M. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3402186 · Cited by 8
Janisch, M., Adelsmayr, G., Müller, H., Holzinger, A., Janek, E., Talakić, E., Fuchsjäger, M., & Schoellnast, H. (2022) · Abdominal Radiology · doi:10.1007/s00261-022-03646-7 · Cited by 8
Unterrainer, M., Deroose, C. M., Herrmann, K., Moehler, M. H., Blomqvist, L., Cannella, R., Caramella, C., Caruso, D., Chouhan, M. D., Denecke, T., et al. (2022) · European Journal of Cancer · doi:10.1016/j.ejca.2022.09.012 · Cited by 8
Lee, S., Lee, S. Y., Kim, S., Huh, Y. J., Lee, J., Lee, K., & Jung, J. (2023) · Diagnostics · doi:10.3390/diagnostics13040755 · Cited by 8
Coordinatized lesion location analysis empowering ROI-based radiomics diagnosis on brain gliomas
Liu, X., Zhang, Q., Li, J., Xu, Q., Zhuo, Z., Li, J., Zhou, X., Lu, M., Zhou, Q.-Q., Pan, H., et al. (2023) · European Radiology · doi:10.1007/s00330-023-09871-y · Cited by 8
Cherezov, D., Viswanathan, V. S., Fu, P., Gupta, A. B., & Madabhushi, A. (2023) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2023.107990 · Cited by 9
Ye, K., Chen, M., Zhu, Q., Lu, Y., & Yuan, H. (2021) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-20-932 · Cited by 8
Bicci, E., Cozzi, D., Cavigli, E., Ruzga, R., Bertelli, E., Danti, G., Bettarini, S., Tortoli, P., Mazzoni, L. N., Busoni, S., et al. (2023) · La radiologia medica · doi:10.1007/s11547-023-01592-y · Cited by 8
Sun, L., Burke, B., Quon, H. C., Swallow, A., Kirkby, C., & Smith, W. (2023) · Advances in Radiation Oncology · doi:10.1016/j.adro.2023.101227 · Cited by 8
Bartholomeus, G. A., van Amsterdam, W. A. C., den Harder, A. M., Willemink, M. J., van Hamersvelt, R. W., de Jong, P. A., & Leiner, T. (2023) · European Radiology · doi:10.1007/s00330-023-09643-8 · Cited by 8
Xue, G., Liu, H., Cai, X., Zhang, Z., Zhang, S., Liu, L., Hu, B., & Wang, G. (2023) · Frontiers in Oncology · doi:10.3389/fonc.2023.1167745 · Cited by 7
Brown, K. H., Payan, N., Osman, S. O. S., Ghita, M., Walls, G., Patallo, I. S., Schettino, G., Prise, K. M., McGarry, C. K., & Butterworth, K. T. (2023) · Physics and Imaging in Radiation Oncology · doi:10.1016/j.phro.2023.100446 · Cited by 7
Impact of slice thickness on reproducibility of CT radiomic features of lung tumors
Gupta, S., Nayak, K., & Pendem, S. (2023) · F1000Research · doi:10.12688/f1000research.141148.1 · Cited by 7
Wang, L., Wang, S., He, Y., Zhu, Y., Li, W., & Tian, J. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630395 · Cited by 7
Low-Cost Probabilistic 3D Denoising with Applications for Ultra-Low-Radiation Computed Tomography
Horenko, I., Pospíšil, L., Vecchi, E., Albrecht, S., Gerber, A., Rehbock, B., Stroh, A., & Gerber, S. (2022) · Journal of Imaging · doi:10.3390/jimaging8060156 · Cited by 8
Statsenko, Y. A., Habuza, T., Talako, T., Pazniak, M., Likhorad, E., Pazniak, A., Beliakouski, P., Gelovani, J. G., Gorkom, K., Almansoori, T. M., et al. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.882190 · Cited by 7
Jeong, D., Hong, Y., Lee, J., Lee, S. B., Cho, Y. J., Shim, H., & Chang, H. (2024) · IEEE Access · doi:10.1109/access.2024.3366989 · Cited by 7
Lee, H., Chang, W., Kim, H. Y., Sung, P., Cho, J., Lee, Y. J., & Kim, Y. H. (2023) · European Radiology · doi:10.1007/s00330-023-10135-y · Cited by 6
Pericoronary radiomics texture features associated with hypercholesterolemia on a photon-counting-CT
Kahmann, J., Tharmaseelan, H., Riffel, P., Overhoff, D., Papavassiliu, T., Schoenberg, S. O., Froelich, M. F., & Ayx, I. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1223035 · Cited by 6
Balagurunathan, Y., Wei, Z., Qi, J., Thompson, Z., Dean, E. A., Lu, H., Vardhanabhuti, S., Corallo, S. A., Choi, J. W., Kim, J. J., et al. (2024) · Frontiers in Oncology · doi:10.3389/fonc.2024.1485039 · Cited by 6
Nayor, M. G., Shen, L., Hunninghake, G. M., Kochunov, P., Barr, R. G., Bluemke, D. A., Broeckel, U., Caravan, P. D., Cheng, S. C., de Vries, P. S., et al. (2021) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.121.012943 · Cited by 5
Müller‐Franzes, G. A., Nebelung, S., Schock, J., Haarburger, C., Khader, F., Pedersoli, F., Schulze-Hagen, M. F., Kuhl, C. K., & Truhn, D. (2022) · Diagnostics · doi:10.3390/diagnostics12020247 · Cited by 6
Quantifying lung cancer heterogeneity using novel CT features: a cross-institute study
Wang, Z., Yang, C., Han, W., Sui, X., Zheng, F., Xue, F., Xu, X., Wu, P. S., Chen, Y., Gu, W., et al. (2022) · Insights into Imaging · doi:10.1186/s13244-022-01204-9 · Cited by 6
Crombé, A., Lafon, M., Nougaret, S., Kind, M., & Cousin, S. (2022) · European Journal of Radiology · doi:10.1016/j.ejrad.2022.110472 · Cited by 6
Park, S. I., Kim, D., Jung, S. C., Nam, Y., Al-Abdulwahhab, A. H., Lee, J.-B., & Choi, K. M. (2023) · Scientific Reports · doi:10.1038/s41598-023-30745-2 · Cited by 6
Hu, M., Wei, W., Zhang, J., Wang, S., Tong, X., Fan, Y., Cheng, Q., Liu, Y., Li, J., & Liu, L. (2024) · Abdominal Radiology · doi:10.1007/s00261-024-04459-6 · Cited by 6
Chang, Y.-S., Nair, J. R., McDougall, C. C., Qiu, W., Banerjee, R. N., Joshi, M., & Lysack, J. T. (2023) · Canadian Association of Radiologists Journal · doi:10.1177/08465371231157592 · Cited by 6
Paving a Path to Clinical Impact with Radiomics: Enabling Reproducibility and Reach
El-Jammal, M., & Chung, C. D. (2025) · Cancer Research · doi:10.1158/0008-5472.can-25-2083 · Cited by 6
Kahmann, J., Nörenberg, D., Papavassiliu, T., Dar, S. U. H., Engelhardt, S., Schoenberg, S. O., Froelich, M. F., & Ayx, I. (2024) · Insights into Imaging · doi:10.1186/s13244-024-01759-9 · Cited by 8
Ibrahim, A., Guha, S., Lu, L., Geng, P., Wu, Q., Chou, Y., Yang, H., Wang, D., Schwartz, L. H., Xie, C., et al. (2024) · PLoS ONE · doi:10.1371/journal.pone.0310486 · Cited by 5
Chirra, P. V., Giriprakash, P. P., Rizk, A. G., Kurowski, J. A., Viswanath, S. E., & Gandhi, N. S. (2024) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-024-01303-7 · Cited by 5
Choe, J., Hwang, H. J., Kim, M. S., Ye, J. C., Oh, G., Lee, S. M., Yun, J., Lee, H. Y., Sun, J. S., You, S., et al. (2024) · European Journal of Radiology · doi:10.1016/j.ejrad.2024.111899 · Cited by 5
Mao, H., Feng, T., Lv, S., Shu, D., Zhu, F., Yang, J., & Zhao, Z. (2025) · European Journal of Radiology · doi:10.1016/j.ejrad.2025.112257 · Cited by 5
Jung, H., Lee, S. M., Kim, Y. C., Byun, J., Park, J. Y., Oh, B. Y., Kwon, M. J., & Kim, J. (2022) · European Journal of Radiology · doi:10.1016/j.ejrad.2022.110193 · Cited by 5
Ilyushenkova, J. N., Sazonova, S. I., Popov, E. V., Batalov, R. E., Minin, S. M., & Romanov, A. B. (2023) · Современные технологии в медицине · doi:10.17691/stm2023.15.2.05 · Cited by 5
He, X., Chen, Z., Gao, Y., Wang, W., & You, M. (2023) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20230180 · Cited by 5
Artificial Intelligence in Medical Imaging by Machine Learning and Deep Learning
Rahate, K., Sengar, M. S., & Patel, S. (2024) · Advances in medical technologies and clinical practice book series · doi:10.4018/979-8-3693-2238-3.ch006 · Cited by 7
Schöneck, M., Lennartz, S., Zopfs, D., Sonnabend, K., Reimer, R. W. M., Rinneburger, M., Graffe, J., ten Persigehl, T., Hentschke, C. M., Baeßler, B., et al. (2024) · European Journal of Radiology · doi:10.1016/j.ejrad.2024.111447 · Cited by 5
Hoye, J., Solomon, J., Sauer, T. J., & Samei, E. (2020) · Academic Radiology · doi:10.1016/j.acra.2020.07.029 · Cited by 5
Self-citationStatsenko, Y. A., Habuza, T., Talako, T., Kurbatova, T., Simiyu, G. L., Smetanina, D., Sido, J., Qandil, D. S., Meribout, S., Gelovani, J. G., et al. (2022) · IEEE Access · doi:10.1109/access.2022.3211080 · Cited by 5
Radiomic phenotyping of the lung parenchyma in a lung cancer screening cohort
Haghighi, B., Horng, H., Noël, P. B., Cohen, E. A., Pantalone, L., Vachani, A., Rendle, K. A. S., Wainwright, J. V., Saia, C. A., Shinohara, R. T., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-29058-1 · Cited by 5
Rigiroli, F., Hoye, J., Lerebours, R. C., Lyu, P., Lafata, K. J., Zhang, A. R., Erkanli, A., Mettu, N. B., Morgan, D. E., Samei, E., et al. (2023) · European Radiology · doi:10.1007/s00330-023-09532-0 · Cited by 5
Self-citationDreyfuss, L. D., Abel, E. J., Nystrom, J. T., Stabo, N. J., Pickhardt, P. J., & Lubner, M. G. (2021) · American Journal of Roentgenology · doi:10.2214/ajr.20.22823 · Cited by 5
Yang, P.-F., Xu, L., Wan, Y., Yang, J., Xue, Y., Jiang, Y., Luo, C., Wang, J., & Niu, T. (2021) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ac16e8 · Cited by 3
Ning, Y., Yu, Q., Fan, X., Jiang, W., Chen, X., Jiang, H., Xie, K., Liu, R., Zhou, Y., Zhang, X., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-17393-4 · Cited by 6
Peoples, J., Hamghalam, M., James, I., Wasim, M., Gangai, N. C., Kang, H. C., Rong, X. J., Chun, Y. S., Gian, R. K., & Simpson, A. L. (2023) · Lecture notes in computer science · doi:10.1007/978-3-031-44336-7_5 · Cited by 4
Wang, J., Dai, G., Ren, X., Shi, R., Luo, R., Liu, J., Deng, K., & Song, J. (2024) · iRadiology · doi:10.1002/ird3.56 · Cited by 4
The potential of photon-counting CT for the improved precision of lung nodule radiomics
McCabe, C., Abadi, E., Zarei, M., Segars, W. P., & Samei, E. (2025) · Physics in Medicine and Biology · doi:10.1088/1361-6560/adaad2 · Cited by 4
Self-citationMitchell-Hay, R., Ahearn, T. S., Murray, A. D., & Waiter, G. D. (2023) · Journal of medical imaging and radiation sciences · doi:10.1016/j.jmir.2023.10.003 · Cited by 4
Yoneyama, M., Matsuo, Y., Kishi, N., Itotani, R., Oguma, T., Ozasa, H., Tanizawa, K., Handa, T., Hirai, T., & Mizowaki, T. (2024) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2024.110408 · Cited by 4
Kravchenko, D., Vecsey-Nagy, M., Varga‐Szemes, Á., Hagar, M. T., Schoepf, U. J., Gnasso, C., Zsarnóczay, E., O’Doherty, J., Caruso, D., Laghi, A., et al. (2024) · International Journal of Cardiology · doi:10.1016/j.ijcard.2024.132749 · Cited by 4
Zholshybek, N., & Bastarbekova, L. (2026) · Exploration of Digital Health Technologies · doi:10.37349/edht.2026.101185 · Cited by 3
Chest CT in COVID-19 Pneumonia: Potentials and Limitations of Radiomics and Artificial Intelligence
Vernuccio, F., Cutaia, G., Cannella, R., Vernuccio, L., Lagalla, R., & Midiri, M. (2021) · Studies in computational intelligence · doi:10.1007/978-3-030-74761-9_3 · Cited by 4
Self-citationChen, Z., Shi, Z.-Z., Lu, F., Li, L., Li, M., Wang, S., Wang, W., Li, Y., Luo, Y., & Tong, D. (2023) · Frontiers in Neurology · doi:10.3389/fneur.2023.1170955 · Cited by 4
Singh, A., Horng, H., Roshkovan, L., Hershman, M., Cohen, E. A., Aggarwal, C., Carpenter, E. L., Katz, S. I., & Despina Kontos, B. (2025) · Scientific Reports · doi:10.1038/s41598-025-18101-y · Cited by 3
Yang, T., Chen, R.-Y., Ding, Y., Wu, J.-Y., Li, Y., & Qiang, J.-W. (2025) · Frontiers in Oncology · doi:10.3389/fonc.2025.1683165 · Cited by 3
Yu, W., McNitt‐Gray, M. F., Goldin, J. G., Song, J. W., & Kim, G. H. J. (2025) · Medical Physics · doi:10.1002/mp.17752 · Cited by 3
Radiomics analysis in gastrointestinal imaging: a narrative review
Santis, D. D., Gaudio, A. D., Zerunian, M., Polici, M., Guido, G., Tarallo, M., Masci, B., Ubaldi, N., Iannicelli, E., Laghi, A., et al. (2023) · Digestive Medicine Research · doi:10.21037/dmr-22-52 · Cited by 2
Peoples, J., Hamghalam, M., James, I., Wasim, M., Gangai, N. C., Kang, H. C., Rong, X. J., Chun, Y. S., Gian, R. K., & Simpson, A. L. (2025) · The Journal of Machine Learning for Biomedical Imaging · doi:10.59275/j.melba.2024-24gc · Cited by 3
Chen, K., Qu, Y., Han, Y. R., Li, Y., Gao, H., & Zheng, D. (2025) · Journal of Medical Internet Research · doi:10.2196/73528 · Cited by 5
Radiomics in cardiovascular imaging: principles and clinical implications
Tokodi, M., Kovács, A. D., & Maurovich‐Horvat, P. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-820273-9.00012-9 · Cited by 3
Lennartz, S., Schlemmer, H., & ten Persigehl, T. (2022) · Die Onkologie · doi:10.1007/s00761-022-01209-5 · Cited by 3
Zhong, J., Xing, Y., Hu, Y., Liu, X., Dai, S., Ding, D., Lu, J. A., Yang, J., Song, Y. S., Lu, M., et al. (2025) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-025-01503-9 · Cited by 2
Krishnan, A. R., Li, T., Remedios, L. W., Kim, M. E., Gao, C., Rudravaram, G., McMaster, E. M., Saunders, A. M., Bao, S., Xu, K., et al. (2025) · Medical Physics · doi:10.1002/mp.70120 · Cited by 2
Yang, H., Zhang, Z., Tian, L., Dang, P., Wan, L., Zhou, Z., Li, J., Cao, L., Yang, X., & Chen, J. (2026) · Insights into Imaging · doi:10.1186/s13244-026-02338-w · Cited by 2
Peri-aortic fat to assess cardiovascular aging using an AI-driven radiomic biomarker
Lebowitz, M., Modanwal, G., Singh, A., Dhamdhere, R., Diwan, S. G., Suleiman, T. A., Al-Shakhshir, H., Gilkey, M., Shofer, S. L., Sirasapalli, S. K., et al. (2026) · European Heart Journal · doi:10.1093/eurheartj/ehag498 · Cited by 2
Pozzi, J., D’Argenzio, J., Carriero, S., Cè, M., D’Arrigo, D., Lanza, C., Biondetti, P., Angileri, S. A., Pavan, M., Catona, R., et al. (2026) · Diagnostics · doi:10.3390/diagnostics16142266 · Cited by 2
Li, Y., Xie, Y., Xu, Y., Zhang, N., Li, G., & Ju, S. (2022) · European Radiology · doi:10.1007/s00330-022-08659-w · Cited by 2
Huang, B.-T., Wang, Y., & Lin, P.-X. (2024) · Journal of Cancer Research and Clinical Oncology · doi:10.1007/s00432-023-05536-x · Cited by 2
Racine, D., Niemann, T., Nemeth, B., Manzano, L. G., Alkadhi, H., Viry, A., Huch, R., Frauenfelder, T., & Euler, A. (2024) · Investigative Radiology · doi:10.1097/rli.0000000000001111 · Cited by 2
Metadata
- Authors
- Meyer, M., Ronald, J., Vernuccio, F., Nelson, R. C., Ramirez-Giraldo, J. C., Solomon, J., Patel, B. N., Samei, E., & Marin, D.
- Affiliations
- Heidelberg University (DE)
- ORCID
- Venue
- Radiology
- Published
- 2019-12
- Volume
- 293
- Issue
- 3
- Pages
- 583-591
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- PMC
- PMC10860741
- OpenAlex
- W2977270522
- Cited by
- 258
- References
- 25
- Citations by year
- 2026: 25 · 2025: 23 · 2024: 32 · 2023: 44 · 2022: 51 · 2021: 57 · 2020: 23 · 2019: 2
- FWCI
- 21.98
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Radiology (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Nova Science Publishers (Nova Science Publishers, Inc.) (submittedVersion)
- Funders
- Siemens Healthineers
- National Institute of Biomedical Imaging and Bioengineering (R01EB001838)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Keywords
- CT radiomics, reproducibility, radiation dose, section thickness, kernel, reconstruction algorithms, correction factors, metastatic liver lesions, hierarchical clustering
- MeSH terms
- Algorithms, Contrast Media, Female, Humans, Liver Neoplasms, Male, Middle Aged, Neoplasm Staging, Prospective Studies, Radiation Dosage, Radiographic Image Interpretation, Computer-Assisted, Tomography, X-Ray Computed, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review