CoChat

Performance of a Deep Learning Algorithm Compared with Radiologic Interpretation for Lung Cancer Detection on Chest Radiographs in a Health Screening Population

Lee, Jong Hyuk, Sun, Hye Young, Park, Sunggyun, Kim, Hyungjin, Hwang, Eui Jin, Goo, Jin Mo, Park, Chang Min · 2020 · Radiology
Cited by 81

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background The performance of a deep learning algorithm for lung cancer detection on chest radiographs in a health screening population is unknown. Purpose To validate a commercially available deep learning algorithm for lung cancer detection on chest radiographs in a health screening population. Materials and Methods Out-of-sample testing of a deep learning algorithm was retrospectively performed using chest radiographs from individuals undergoing a comprehensive medical check-up between July 2008 and December 2008 (validation test). To evaluate the algorithm performance for visible lung cancer detection, the area under the receiver operating characteristic curve (AUC) and diagnostic measures, including sensitivity and false-positive rate (FPR), were calculated. The algorithm performance was compared with that of radiologists using the McNemar test and the Moskowitz method. Additionally, the deep learning algorithm was applied to a screening cohort undergoing chest radiography between January 2008 and December 2012, and its performances were calculated. Results In a validation test comprising 10 285 radiographs from 10 202 individuals (mean age, 54 years ± 11 [standard deviation]; 5857 men) with 10 radiographs of visible lung cancers, the algorithm’s AUC was 0.99 (95% confidence interval: 0.97, 1), and it showed comparable sensitivity (90% [nine of 10 radiographs]) to that of the radiologists (60% [six of 10 radiographs]; P = .25) with a higher FPR (3.1% [319 of 10 275 radiographs] vs 0.3% [26 of 10 275 radiographs]; P < .001). In the screening cohort of 100 525 chest radiographs from 50 070 individuals (mean age, 53 years ± 11; 28 090 men) with 47 radiographs of visible lung cancers, the algorithm’s AUC was 0.97 (95% confidence interval: 0.95, 0.99), and its sensitivity and FPR were 83% (39 of 47 radiographs) and 3% (2999 of 100 478 radiographs), respectively. Conclusion A deep learning algorithm detected lung cancers on chest radiographs with a performance comparable to that of radiologists, which will be helpful for radiologists in healthy populations with a low prevalence of lung cancer. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Armato in this issue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2020201240

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 81

Metadata

Authors
Lee, J. H., Sun, H. Y., Park, S., Kim, H., Hwang, E. J., Goo, J. M., & Park, C. M.
Venue
Radiology
Published
2020-12
Volume
297
Issue
3
Pages
687-696
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W3088366593
Cited by
81
References
3
FWCI
4.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.