The DOI matches its Crossref record.
Supplemental Breast MRI for Women with Extremely Dense Breasts: Results of the Second Screening Round of the DENSE Trial
Open accessAbstract
Background In the first (prevalent) supplemental MRI screening round of the Dense Tissue and Early Breast Neoplasm Screening (DENSE) trial, a considerable number of breast cancers were found at the cost of an increased false-positive rate (FPR). In incident screening rounds, a lower cancer detection rate (CDR) is expected due to a smaller pool of prevalent cancers, and a reduced FPR, due to the availability of prior MRI examinations. Purpose To investigate screening performance indicators of the second round (incidence round) of the DENSE trial. Materials and Methods The DENSE trial (ClinicalTrials.gov: NCT01315015) is embedded within the Dutch population–based biennial mammography screening program for women aged 50–75 years. MRI examinations were performed between December 2011 and January 2016. Women were eligible for the second round when they again had a negative screening mammogram 2 years after their first MRI. The recall rate, biopsy rate, CDR, FPR, positive predictive values, and distributions of tumor characteristics were calculated and compared with results of the first round using 95% CIs and χ2 tests. Results A total of 3436 women (median age, 56 years; interquartile range, 48–64 years) underwent a second MRI screening. The CDR was 5.8 per 1000 screening examinations (95% CI: 3.8, 9.0) compared with 16.5 per 1000 screening examinations (95% CI: 13.3, 20.5) in the first round. The FPR was 26.3 per 1000 screening examinations (95% CI: 21.5, 32.3) in the second round versus 79.8 per 1000 screening examinations (95% CI: 72.4, 87.9) in the first round. The positive predictive value for recall was 18% (20 of 110 participants recalled; 95% CI: 12.1, 26.4), and the positive predictive value for biopsy was 24% (20 of 84 participants who underwent biopsy; 95% CI: 16.0, 33.9), both comparable to that of the first round. All tumors in the second round were stage 0–I and node negative. Conclusion The incremental cancer detection rate in the second round was 5.8 per 1000 screening examinations—compared with 16.5 per 1000 screening examinations in the first round. This was accompanied by a strong reduction in the number of false-positive results. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Moy and Gao in this issue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Screening for Breast Cancer: US Preventive Services Task Force Recommendation Statement
US Preventive Services Task Force, Nicholson, W. K., Silverstein, M., Wong, J. B., Barry, M. J., Chelmow, D., Coker, T. R., Davis, E. M., Jaén, C. R., Krousel-Wood, M., et al. (2024) · JAMA · doi:10.1001/jama.2024.5534 · Cited by 463
Breast Cancer Screening for Women at Higher-Than-Average Risk: Updated Recommendations From the ACR
Monticciolo, D. L., Newell, M. S., Moy, L., Lee, C. S., & Destounis, S. V. (2023) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2023.04.002 · Cited by 290
Artificial intelligence in senology—where do we stand and what are the future horizons?
Mundinger, A., & Mundinger, C. (2024) · European Journal of Breast Health · doi:10.4274/ejbh.galenos.2024.2023-12-13 · Cited by 9
Metadata
- Authors
- Veenhuizen, S. G. A., de Lange, S. V., Bakker, M. F., Pijnappel, R. M., Mann, R. M., Monninkhof, E. M., Emaus, M. J., de Koekkoek-Doll, P. K., Bisschops, R. H. C., Lobbes, M. B. I., de Jong, M. D. F., Duvivier, K. M., Veltman, J., Karssemeijer, N., de Koning, H. J., van Diest, P. J., Mali, W. P. T. M., van den Bosch, M. A. A. J., van Gils, C. H., Veldhuis, W. B., For the DENSE Trial Study Group, van Gils, C. H., Bakker, M. F., de Lange, S. V., Veenhuizen, S. G. A., Veldhuis, W. B., Pijnappel, R. M., Emaus, M. J., Peeters, P. H. M., Monninkhof, E. M., Fernandez-Gallardo, M. A., Mali, W. P. T. M., van den Bosch, M. A. A. J., van Diest, P. J., Mann, R. M., Mus, R., Imhof-Tas, M., Karssemeijer, N., Loo, C. E., de Koekkoek-Doll, P. K., Winter-Warnars, H. A. O., Bisschops, R. H. C., Kock, M. C. J. M., Storm, R. K., van der Valk, P. H. M., Lobbes, M. B. I., Gommers, S., Lobbes, M. B. I., de Jong, M. D. F., Rutten, M. J. C. M., Duvivier, K. M., de Graaf, P., Veltman, J., Bourez, R. L. J. H., & de Koning, H. J.
- Venue
- Radiology
- Published
- 2021-05
- Volume
- 299
- Issue
- 2
- Pages
- 278-286
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W3137095879
- Cited by
- 174
- References
- 0
- Type
- supplementary materials
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Supplemental Breast MRI for Women with Extremely Dense Breasts: Results of the Second Screening Round of the DENSE Trial. https://app.cochat.ai/papers/10.1148/radiol.2021203633
- The paper
- Veenhuizen, S. G. A., de Lange, S. V., Bakker, M. F., Pijnappel, R. M., Mann, R. M., Monninkhof, E. M., Emaus, M. J., de Koekkoek-Doll, P. K., Bisschops, R. H. C., Lobbes, M. B. I., de Jong, M. D. F., Duvivier, K. M., Veltman, J., Karssemeijer, N., de Koning, H. J., van Diest, P. J., Mali, W. P. T. M., van den Bosch, M. A. A. J., van Gils, C. H., . . . de Koning, H. J. (2021). Supplemental Breast MRI for Women with Extremely Dense Breasts: Results of the Second Screening Round of the DENSE Trial. Radiology. https://doi.org/10.1148/radiol.2021203633
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.