Background Accurate estimation of the malignancy risk of pulmonary nodules at chest CT is crucial for optimizing management in lung cancer screening. Purpose To develop and validate a deep learning (DL) algorithm for malignancy risk estimation of pulmonary nodules detected at screening CT. Materials and Methods In this retrospective study, the DL algorithm was developed with 16 077 nodules (1249 malignant) collected between 2002 and 2004 from the National Lung Screening Trial. External validation was performed in the following three cohorts collected between 2004 and 2010 from the Danish Lung Cancer Screening Trial: a full cohort containing all 883 nodules (65 malignant) and two cancer-enriched cohorts with size matching (175 nodules, 59 malignant) and without size matching (177 nodules, 59 malignant) of benign nodules selected at random. Algorithm performance was measured by using the area under the receiver operating characteristic curve (AUC) and compared with that of the Pan-Canadian Early Detection of Lung Cancer (PanCan) model in the full cohort and a group of 11 clinicians composed of four thoracic radiologists, five radiology residents, and two pulmonologists in the cancer-enriched cohorts. Results The DL algorithm significantly outperformed the PanCan model in the full cohort (AUC, 0.93 [95% CI: 0.89, 0.96] vs 0.90 [95% CI: 0.86, 0.93]; P = .046). The algorithm performed comparably to thoracic radiologists in cancer-enriched cohorts with both random benign nodules (AUC, 0.96 [95% CI: 0.93, 0.99] vs 0.90 [95% CI: 0.81, 0.98]; P = .11) and size-matched benign nodules (AUC, 0.86 [95% CI: 0.80, 0.91] vs 0.82 [95% CI: 0.74, 0.89]; P = .26). Conclusion The deep learning algorithm showed excellent performance, comparable to thoracic radiologists, for malignancy risk estimation of pulmonary nodules detected at screening CT. This algorithm has the potential to provide reliable and reproducible malignancy risk scores for clinicians, which may help optimize management in lung cancer screening. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Tammemägi in this issue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening
The National Lung Screening Trial Research Team (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1102873 · Cited by 11,064 · cited 1×
“In this study, we developed a deep learning algorithm for malignancy risk estimation of pulmonary nodules by using low-dose CT examinations from the National Lung Screening Trial (1) and externally validated it in the Danish Lung Cancer Screening Trial (DLCST) (18).”
Quo Vadis, Action Recognition? A New Model and the Kinetics Dataset
Carreira, J., & Zisserman, A. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.502 · Cited by 9,570
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Reduced Lung-Cancer Mortality with Volume CT Screening in a Randomized Trial
de Koning, H. J., van der Aalst, C. M., de Jong, P. A., Scholten, E. T., Nackaerts, K., Heuvelmans, M. A., Lammers, J.-W. J., Weenink, C., Yousaf-Khan, U., Horeweg, N., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1911793 · Cited by 3,624
Self-citationArmato, S. G., McLennan, G., Bidaut, L., McNitt‐Gray, M. F., Meyer, C. R., Reeves, A. P., Zhao, B., Aberle, D. R., Henschke, C. I., Hoffman, E. A., et al. (2011) · Medical Physics · doi:10.1118/1.3528204 · Cited by 2,887
MacMahon, H., Naidich, D. P., Goo, J. M., Lee, K. S., Leung, A. N. C., Mayo, J. R., Mehta, A. C., Ohno, Y., Powell, C. A., Prokop, M., et al. (2017) · Radiology · doi:10.1148/radiol.2017161659 · Cited by 2,491
Self-citationArdila, D., Kiraly, A. P., Bharadwaj, S., Choi, B., Reicher, J. J., Peng, L., Tse, D., Etemadi, M., Ye, W., Corrado, G., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0447-x · Cited by 2,167 · cited 2×
“The two-dimensional CNN was based on the system developed by Setio et al (21) with ResNet50 (22) backbone, and the three-dimensional CNN was based on three-dimensional– inflated Incep-tion-v1 architecture (open source; https://github.com/hassony2/ kinetics_i3d_pytorch ) (15,23).”
Setio, A. A. A., Ciompi, F., Litjens, G., Gerke, P., Jacobs, C., van Riel, S. J., Wille, M. M. W., Naqibullah, M., Sanchez, C. I., & van Ginneken, B. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2536809 · Cited by 1,258
Self-citationPresenting machine learning model information to clinical end users with model facts labels
Sendak, M. P., Gao, M., Brajer, N., & Balu, S. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0253-3 · Cited by 279 · cited 1×
“We made the algorithm freely accessible to the public for research purposes ( https://grand-challenge.org/algorithms/pulmo-nary-nodule-malignancy-prediction ) along with a Model Facts label (26) containing the most important information for end users (Appendix E1 [online]).”
Cited by
Adams, S. J., Stone, E., Baldwin, D. R., Vliegenthart, R., Lee, P., & Fintelmann, F. J. (2023) · The Lancet · doi:10.1016/s0140-6736(22)01694-4 · Cited by 467
Machine Learning for Lung Cancer Diagnosis, Treatment, and Prognosis
Li, Y., Wu, X., Yang, P., Jiang, G., & Luo, Y. (2022) · Genomics, Proteomics & Bioinformatics · doi:10.1016/j.gpb.2022.11.003 · Cited by 263
Novel research and future prospects of artificial intelligence in cancer diagnosis and treatment
Zhang, C., Xu, J., Tang, R., Yang, J., Wang, W., Yu, X., & Shi, S. (2023) · Journal of Hematology & Oncology · doi:10.1186/s13045-023-01514-5 · Cited by 148
Sunoqrot, M. R. S., Saha, A., Hosseinzadeh, M., Elschot, M., & Huisman, H. (2022) · European Radiology Experimental · doi:10.1186/s41747-022-00288-8 · Cited by 76
“Similar developments have already been seen in other medical imaging domains such as breast [74] and lung [75].”
ResultTHONG, L. T., CHOU, H. S., CHEW, H. S. J., & LAU, Y. (2023) · Lung Cancer · doi:10.1016/j.lungcan.2022.12.002 · Cited by 67
Vaidhya Venkadesh, K., Aleef, T. A., Scholten, E. T., Saghir, Z., Silva, M., Sverzellati, N., Pastorino, U., van Ginneken, B., Prokop, M., & Jacobs, C. (2023) · Radiology · doi:10.1148/radiol.223308 · Cited by 32
Self-citationThe impact of AI on modern oncology from early detection to personalized cancer treatment
Li, J., Zhang, L., Yu, Z., Bao, Z., Li, D., & Wang, L. (2026) · npj Precision Oncology · doi:10.1038/s41698-026-01276-6 · Cited by 24
“93 126 .”
Marcinkiewicz, A. M., Buchwald, M., Shanbhag, A., Bednarski, B. P., Killekar, A., Miller, R. J. H., Builoff, V., Lemley, M., Berman, D. S., Dey, D., et al. (2024) · Radiology · doi:10.1148/radiol.240541 · Cited by 20
Machine Learning Applications in Lung Cancer Diagnosis, Treatment and Prognosis
Li, Y., Wu, X., Yang, P., Jiang, G., & Luo, Y. (2022) · arXiv · doi:10.48550/arxiv.2203.02794 · Cited by 2
Metadata
- Authors
- Venkadesh, K. V., Setio, A. A. A., Schreuder, A., Scholten, E. T., Chung, K., W. Wille, M. M., Saghir, Z., van Ginneken, B., Prokop, M., & Jacobs, C.
- Venue
- Radiology
- Published
- 2021-08
- Volume
- 300
- Issue
- 2
- Pages
- 438-447
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W3161948739
- Cited by
- 179
- References
- 12
- FWCI
- 14.75
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.