CoChat

Artificial Intelligence for Reducing Workload in Breast Cancer Screening with Digital Breast Tomosynthesis

Open access
Shoshan, Yoel, Bakalo, Ran, Gilboa-Solomon, Flora, Ratner, Vadim, Barkan, Ella, Ozery-Flato, Michal, Amit, Mika, Khapun, Daniel, Ambinder, Emily B., Oluyemi, Eniola T., Panigrahi, Babita, DiCarlo, Philip A., Rosen-Zvi, Michal, Mullen, Lisa A. · 2022 · Radiology
Cited by 76

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background Digital breast tomosynthesis (DBT) has higher diagnostic accuracy than digital mammography, but interpretation time is substantially longer. Artificial intelligence (AI) could improve reading efficiency. Purpose To evaluate the use of AI to reduce workload by filtering out normal DBT screens. Materials and Methods The retrospective study included 13 306 DBT examinations from 9919 women performed between June 2013 and November 2018 from two health care networks. The cohort was split into training, validation, and test sets (3948, 1661, and 4310 women, respectively). A workflow was simulated in which the AI model classified cancer-free examinations that could be dismissed from the screening worklist and used the original radiologists’ interpretations on the rest of the worklist examinations. The AI system was also evaluated with a reader study of five breast radiologists reading the DBT mammograms of 205 women. The area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and recall rate were evaluated in both studies. Statistics were computed across 10 000 bootstrap samples to assess 95% CIs, noninferiority, and superiority tests. Results The model was tested on 4310 screened women (mean age, 60 years ± 11 [standard deviation]; 5182 DBT examinations). Compared with the radiologists’ performance (417 of 459 detected cancers [90.8%], 477 recalls in 5182 examinations [9.2%]), the use of AI to automatically filter out cases would result in 39.6% less workload, noninferior sensitivity (413 of 459 detected cancers; 90.0%; P = .002), and 25% lower recall rate (358 recalls in 5182 examinations; 6.9%; P = .002). In the reader study, AUC was higher in the standalone AI compared with the mean reader (0.84 vs 0.81; P = .002). Conclusion The artificial intelligence model was able to identify normal digital breast tomosynthesis screening examinations, which decreased the number of examinations that required radiologist interpretation in a simulated clinical workflow. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Philpotts in this issue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.211105

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 76

Metadata

Authors
Shoshan, Y., Bakalo, R., Gilboa-Solomon, F., Ratner, V., Barkan, E., Ozery-Flato, M., Amit, M., Khapun, D., Ambinder, E. B., Oluyemi, E. T., Panigrahi, B., DiCarlo, P. A., Rosen-Zvi, M., & Mullen, L. A.
Venue
Radiology
Published
2022-04
Volume
303
Issue
1
Pages
69-77
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W4206285699
Cited by
76
References
4
FWCI
5.09
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Artificial Intelligence for Reducing Workload in Breast Cancer Screening with Digital Breast Tomosynthesis. https://app.cochat.ai/papers/10.1148/radiol.211105
The paper
Shoshan, Y., Bakalo, R., Gilboa-Solomon, F., Ratner, V., Barkan, E., Ozery-Flato, M., Amit, M., Khapun, D., Ambinder, E. B., Oluyemi, E. T., Panigrahi, B., DiCarlo, P. A., Rosen-Zvi, M., & Mullen, L. A. (2022). Artificial Intelligence for Reducing Workload in Breast Cancer Screening with Digital Breast Tomosynthesis. Radiology. https://doi.org/10.1148/radiol.211105

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.