The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Coronary CT Angiography with Photon-counting CT: First-In-Human Results
Abstract
Background Spatial resolution, soft-tissue contrast, and dose-efficient capabilities of photon-counting CT (PCCT) potentially allow a better quality and diagnostic confidence of coronary CT angiography (CCTA) in comparison to conventional CT. Purpose To compare the quality of CCTA scans obtained with a clinical prototype PCCT system and an energy-integrating detector (EID) dual-layer CT (DLCT) system. Materials and Methods In this prospective board-approved study with informed consent, participants with coronary artery disease underwent retrospective electrocardiographically gated CCTA with both systems after injection of 65–75 mL of 400 mg/mL iodinated contrast agent at 5 mL/sec. A prior phantom task-based quality assessment of the detectability index of coronary lesions was performed. Ultra-high-resolution parameters were used for PCCT (1024 matrix, 0.25-mm section thickness) and EID DLCT (512 matrix, 0.67-mm section thickness). Three cardiac radiologists independently performed a blinded analysis using a five-point quality score (1 = insufficient, 5 = excellent) for overall image quality, diagnostic confidence, and diagnostic quality of calcifications, stents, and noncalcified plaques. A logistic regression model, adjusted for radiologists, was used to evaluate the proportion of improvement in scores with the best method. Results Fourteen consecutive participants (12 men; mean age, 61 years ± 17) were enrolled. Scores of overall quality and diagnostic confidence were higher with PCCT images with a median of 5 (interquartile range [IQR], 2) and 5 (IQR, 1) versus 4 (IQR, 1) and 4 (IQR, 3) with EID DLCT images, using a mean tube current of 255 mAs ± 0 versus 349 mAs ± 111 for EID DLCT images (P < .01). Proportions of improvement with PCCT images for quality of calcification, stent, and noncalcified plaque were 100%, 92% (95% CI: 71, 98), and 45% (95% CI: 28, 63), respectively. In the phantom study, detectability indexes were 2.3-fold higher for lumen and 2.9-fold higher for noncalcified plaques with PCCT images. Conclusion Coronary CT angiography with a photon-counting CT system demonstrated in humans an improved image quality and diagnostic confidence compared with an energy-integrating dual-layer CT. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Sandfort and Bluemke in this issue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2019 ESC Guidelines for the diagnosis and management of chronic coronary syndromes
Knuuti, J., Wijns, W., Saraste, A., Capodanno, D., Barbato, E., Funck-Brentano, C., Prescott, E., Storey, R. F., Deaton, C., Cuisset, T., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz425 · Cited by 7,166
Coronary CT Angiography and 5-Year Risk of Myocardial Infarction
The SCOT-HEART Investigators (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1805971 · Cited by 1,390
2010 ACCF/AHA Guideline for Assessment of Cardiovascular Risk in Asymptomatic Adults
Greenland, P., Alpert, J. S., Beller, G. A., Benjamin, E. J., Budoff, M. J., Fayad, Z. A., Foster, E., Hlatky, M. A., Hodgson, J. M., Kushner, F. G., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.001 · Cited by 1,324
Abbara, S., Blanke, P., Maroules, C. D., Cheezum, M., Choi, A. D., Han, B. K., Marwan, M., Naoum, C., Norgaard, B. L., Rubinshtein, R., et al. (2016) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2016.10.002 · Cited by 1,095
Vision 20/20: Single photon counting x‐ray detectors in medical imaging
Taguchi, K., & Iwanczyk, J. S. (2013) · Medical Physics · doi:10.1118/1.4820371 · Cited by 948
Coronary CT Angiography versus Standard Evaluation in Acute Chest Pain
Hoffmann, U., Truong, Q. A., Schoenfeld, D. A., Chou, E. T., Woodard, P. K., Nagurney, J. T., Pope, J. H., Hauser, T. H., White, C. S., Weiner, S. G., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1201161 · Cited by 903
Greffier, J., Hamard, A., Pereira, F., Barrau, C., Pasquier, H., Beregi, J. P., & Frandon, J. (2020) · European Radiology · doi:10.1007/s00330-020-06724-w · Cited by 328
Self-citationGutjahr, R., Halaweish, A. F., Yu, Z., Leng, S., Yu, L., Li, Z., Jorgensen, S. M., Ritman, E. L., Kappler, S., & McCollough, C. H. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000251 · Cited by 282
Feuerlein, S., Roessl, E., Proksa, R., Martens, G., Klass, O., Jeltsch, M., Rasche, V., Brambs, H.-J., Hoffmann, M. H. K., & Schlomka, J.-P. (2008) · Radiology · doi:10.1148/radiol.2492080560 · Cited by 195
Feasibility of Dose-reduced Chest CT with Photon-counting Detectors: Initial Results in Humans
Symons, R., Pourmorteza, A., Sandfort, V., Ahlman, M. A., Cropper, T., Mallek, M., Kappler, S., Ulzheimer, S., Mahesh, M., Jones, E. C., et al. (2017) · Radiology · doi:10.1148/radiol.2017162587 · Cited by 188
Cited by
Charting the Unseen: How Non-Invasive Imaging Could Redefine Cardiovascular Prevention
Trimarchi, G., Pizzino, F., Paradossi, U., Gueli, I. A., Palazzini, M., Gentile, P., Di Spigno, F., Ammirati, E., Garascia, A., Tedeschi, A., et al. (2024) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd11080245 · Cited by 45
Metadata
- Authors
- Si-Mohamed, S. A., Boccalini, S., Lacombe, H., Diaw, A., Varasteh, M., Rodesch, P.-A., Dessouky, R., Villien, M., Tatard-Leitman, V., Bochaton, T., Coulon, P., Yagil, Y., Lahoud, E., Erhard, K., Riche, B., Bonnefoy, E., Rioufol, G., Finet, G., Bergerot, C., Boussel, L., Greffier, J., & Douek, P. C.
- Venue
- Radiology
- Published
- 2022-05
- Volume
- 303
- Issue
- 2
- Pages
- 303-313
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W4213352797
- Cited by
- 306
- References
- 17
- FWCI
- 34.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coronary CT Angiography with Photon-counting CT: First-In-Human Results. https://app.cochat.ai/papers/10.1148/radiol.211780
- The paper
- Si-Mohamed, S. A., Boccalini, S., Lacombe, H., Diaw, A., Varasteh, M., Rodesch, P.-A., Dessouky, R., Villien, M., Tatard-Leitman, V., Bochaton, T., Coulon, P., Yagil, Y., Lahoud, E., Erhard, K., Riche, B., Bonnefoy, E., Rioufol, G., Finet, G., Bergerot, C., . . . Douek, P. C. (2022). Coronary CT Angiography with Photon-counting CT: First-In-Human Results. Radiology. https://doi.org/10.1148/radiol.211780
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.