Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Feasibility of Dose-reduced Chest CT with Photon-counting Detectors: Initial Results in Humans

Open access
Symons, Rolf, Pourmorteza, Amir, Sandfort, Veit, Ahlman, Mark A., Cropper, Tracy, Mallek, Marissa, Kappler, Steffen, Ulzheimer, Stefan, Mahesh, Mahadevappa, Jones, Elizabeth C., Malayeri, Ashkan A., Folio, Les R., Bluemke, David A. · 2017 · Radiology

Abstract

Purpose To investigate whether photon-counting detector (PCD) technology can improve dose-reduced chest computed tomography (CT) image quality compared with that attained with conventional energy-integrating detector (EID) technology in vivo. Materials and Methods This was a HIPAA-compliant institutional review board-approved study, with informed consent from patients. Dose-reduced spiral unenhanced lung EID and PCD CT examinations were performed in 30 asymptomatic volunteers in accordance with manufacturer-recommended guidelines for CT lung cancer screening (120-kVp tube voltage, 20-mAs reference tube current–time product for both detectors). Quantitative analysis of images included measurement of mean attenuation, noise power spectrum (NPS), and lung nodule contrast-to-noise ratio (CNR). Images were qualitatively analyzed by three radiologists blinded to detector type. Reproducibility was assessed with the intraclass correlation coefficient (ICC). McNemar, paired t, and Wilcoxon signed-rank tests were used to compare image quality. Results Thirty study subjects were evaluated (mean age, 55.0 years ± 8.7 [standard deviation]; 14 men). Of these patients, 10 had a normal body mass index (BMI) (BMI range, 18.5–24.9 kg/m2; group 1), 10 were overweight (BMI range, 25.0–29.9 kg/m2; group 2), and 10 were obese (BMI ≥30.0 kg/m2, group 3). PCD diagnostic quality was higher than EID diagnostic quality (P = .016, P = .016, and P = .013 for readers 1, 2, and 3, respectively), with significantly better NPS and image quality scores for lung, soft tissue, and bone and with fewer beam-hardening artifacts (all P < .001). Image noise was significantly lower for PCD images in all BMI groups (P < .001 for groups 1 and 3, P < .01 for group 2), with higher CNR for lung nodule detection (12.1 ± 1.7 vs 10.0 ± 1.8, P < .001). Inter- and intrareader reproducibility were good (all ICC > 0.800). Conclusion Initial human experience with dose-reduced PCD chest CT demonstrated lower image noise compared with conventional EID CT, with better diagnostic quality and lung nodule CNR. © RSNA, 2017 Online supplemental material is available for this article.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2017162587

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 188

Metadata

Authors
Symons, R., Pourmorteza, A., Sandfort, V., Ahlman, M. A., Cropper, T., Mallek, M., Kappler, S., Ulzheimer, S., Mahesh, M., Jones, E. C., Malayeri, A. A., Folio, L. R., & Bluemke, D. A.
Venue
Radiology
Published
2017-12
Volume
285
Issue
3
Pages
980-989
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2740188036
Cited by
188
References
2
FWCI
4.77
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Feasibility of Dose-reduced Chest CT with Photon-counting Detectors: Initial Results in Humans. https://app.cochat.ai/papers/10.1148/radiol.2017162587
The paper
Symons, R., Pourmorteza, A., Sandfort, V., Ahlman, M. A., Cropper, T., Mallek, M., Kappler, S., Ulzheimer, S., Mahesh, M., Jones, E. C., Malayeri, A. A., Folio, L. R., & Bluemke, D. A. (2017). Feasibility of Dose-reduced Chest CT with Photon-counting Detectors: Initial Results in Humans. Radiology. https://doi.org/10.1148/radiol.2017162587

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.