Feasibility of Dose-reduced Chest CT with Photon-counting Detectors: Initial Results in Humans
Open accessAbstract
Purpose To investigate whether photon-counting detector (PCD) technology can improve dose-reduced chest computed tomography (CT) image quality compared with that attained with conventional energy-integrating detector (EID) technology in vivo. Materials and Methods This was a HIPAA-compliant institutional review board-approved study, with informed consent from patients. Dose-reduced spiral unenhanced lung EID and PCD CT examinations were performed in 30 asymptomatic volunteers in accordance with manufacturer-recommended guidelines for CT lung cancer screening (120-kVp tube voltage, 20-mAs reference tube current–time product for both detectors). Quantitative analysis of images included measurement of mean attenuation, noise power spectrum (NPS), and lung nodule contrast-to-noise ratio (CNR). Images were qualitatively analyzed by three radiologists blinded to detector type. Reproducibility was assessed with the intraclass correlation coefficient (ICC). McNemar, paired t, and Wilcoxon signed-rank tests were used to compare image quality. Results Thirty study subjects were evaluated (mean age, 55.0 years ± 8.7 [standard deviation]; 14 men). Of these patients, 10 had a normal body mass index (BMI) (BMI range, 18.5–24.9 kg/m2; group 1), 10 were overweight (BMI range, 25.0–29.9 kg/m2; group 2), and 10 were obese (BMI ≥30.0 kg/m2, group 3). PCD diagnostic quality was higher than EID diagnostic quality (P = .016, P = .016, and P = .013 for readers 1, 2, and 3, respectively), with significantly better NPS and image quality scores for lung, soft tissue, and bone and with fewer beam-hardening artifacts (all P < .001). Image noise was significantly lower for PCD images in all BMI groups (P < .001 for groups 1 and 3, P < .01 for group 2), with higher CNR for lung nodule detection (12.1 ± 1.7 vs 10.0 ± 1.8, P < .001). Inter- and intrareader reproducibility were good (all ICC > 0.800). Conclusion Initial human experience with dose-reduced PCD chest CT demonstrated lower image noise compared with conventional EID CT, with better diagnostic quality and lung nodule CNR. © RSNA, 2017 Online supplemental material is available for this article.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Practical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
Forming inferences about some intraclass correlation coefficients.
McGraw, K. O., & Wong, S. P. (1996) · Psychological Methods · doi:10.1037/1082-989x.1.1.30 · Cited by 6,903
Cited by
Photon-counting CT: Technical Principles and Clinical Prospects
Willemink, M. J., Persson, M., Pourmorteza, A., Pelc, N. J., & Fleischmann, D. (2018) · Radiology · doi:10.1148/radiol.2018172656 · Cited by 1,326
Self-citationFlohr, T., Petersilka, M., Henning, A., Ulzheimer, S., Ferda, J., & Schmidt, B. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.10.030 · Cited by 581
Self-citationCoronary CT Angiography with Photon-counting CT: First-In-Human Results
Si-Mohamed, S. A., Boccalini, S., Lacombe, H., Diaw, A., Varasteh, M., Rodesch, P.-A., Dessouky, R., Villien, M., Tatard-Leitman, V., Bochaton, T., et al. (2022) · Radiology · doi:10.1148/radiol.211780 · Cited by 306
Badea, C. T., Clark, D. P., Holbrook, M., Srivastava, M., Mowery, Y., & Ghaghada, K. B. (2019) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab03e2 · Cited by 74
Nowak, T., Eberhard, M., Schmidt, B., Frey, D., Distler, O., Saltybaeva, N., Alkadhi, H., & Euler, A. (2021) · Radiology · doi:10.1148/radiol.2020202767 · Cited by 41
Metadata
- Authors
- Symons, R., Pourmorteza, A., Sandfort, V., Ahlman, M. A., Cropper, T., Mallek, M., Kappler, S., Ulzheimer, S., Mahesh, M., Jones, E. C., Malayeri, A. A., Folio, L. R., & Bluemke, D. A.
- Venue
- Radiology
- Published
- 2017-12
- Volume
- 285
- Issue
- 3
- Pages
- 980-989
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2740188036
- Cited by
- 188
- References
- 2
- FWCI
- 4.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Feasibility of Dose-reduced Chest CT with Photon-counting Detectors: Initial Results in Humans. https://app.cochat.ai/papers/10.1148/radiol.2017162587
- The paper
- Symons, R., Pourmorteza, A., Sandfort, V., Ahlman, M. A., Cropper, T., Mallek, M., Kappler, S., Ulzheimer, S., Mahesh, M., Jones, E. C., Malayeri, A. A., Folio, L. R., & Bluemke, D. A. (2017). Feasibility of Dose-reduced Chest CT with Photon-counting Detectors: Initial Results in Humans. Radiology. https://doi.org/10.1148/radiol.2017162587
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.