The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Pancreatic Cancer Detection on CT Scans with Deep Learning: A Nationwide Population-based Study
Abstract
Background Approximately 40% of pancreatic tumors smaller than 2 cm are missed at abdominal CT. Purpose To develop and to validate a deep learning (DL)–based tool able to detect pancreatic cancer at CT. Materials and Methods Retrospectively collected contrast-enhanced CT studies in patients diagnosed with pancreatic cancer between January 2006 and July 2018 were compared with CT studies of individuals with a normal pancreas (control group) obtained between January 2004 and December 2019. An end-to-end tool comprising a segmentation convolutional neural network (CNN) and a classifier ensembling five CNNs was developed and validated in the internal test set and a nationwide real-world validation set. The sensitivities of the computer-aided detection (CAD) tool and radiologist interpretation were compared using the McNemar test. Results A total of 546 patients with pancreatic cancer (mean age, 65 years ± 12 [SD], 297 men) and 733 control subjects were randomly divided into training, validation, and test sets. In the internal test set, the DL tool achieved 89.9% (98 of 109; 95% CI: 82.7, 94.9) sensitivity and 95.9% (141 of 147; 95% CI: 91.3, 98.5) specificity (area under the receiver operating characteristic curve [AUC], 0.96; 95% CI: 0.94, 0.99), without a significant difference (P = .11) in sensitivity compared with the original radiologist report (96.1% [98 of 102]; 95% CI: 90.3, 98.9). In a test set of 1473 real-world CT studies (669 malignant, 804 control) from institutions throughout Taiwan, the DL tool distinguished between CT malignant and control studies with 89.7% (600 of 669; 95% CI: 87.1, 91.9) sensitivity and 92.8% specificity (746 of 804; 95% CI: 90.8, 94.5) (AUC, 0.95; 95% CI: 0.94, 0.96), with 74.7% (68 of 91; 95% CI: 64.5, 83.3) sensitivity for malignancies smaller than 2 cm. Conclusion The deep learning–based tool enabled accurate detection of pancreatic cancer on CT scans, with reasonable sensitivity for tumors smaller than 2 cm. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Aisen and Rodrigues in this issue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
A guide to deep learning in healthcare
Esteva, A., Robicquet, A., Ramsundar, B., Kuleshov, V., DePristo, M., Chou, K., Cui, C., Corrado, G., Thrun, S., & Dean, J. (2019) · Nature Medicine · doi:10.1038/s41591-018-0316-z · Cited by 5,312
Diagnostic tests 4: likelihood ratios
Deeks, J. J., & Altman, D. G. (2004) · BMJ · doi:10.1136/bmj.329.7458.168 · Cited by 1,600
Automated cardiovascular magnetic resonance image analysis with fully convolutional networks
Bai, W., Sinclair, M., Tarroni, G., Oktay, O., Rajchl, M., Vaillant, G., Lee, A. M., Aung, N., Lukaschuk, E., Sanghvi, M. M., et al. (2018) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-018-0471-x · Cited by 773
Kim, D. W., Jang, H. Y., Kim, K. W., Shin, Y., & Park, S. H. (2019) · Korean Journal of Radiology · doi:10.3348/kjr.2019.0025 · Cited by 459
Liu, K.-L., Wu, T., Chen, P.-T., Tsai, Y. M., Roth, H., Wu, M.-S., Liao, W.-C., & Wang, W. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30078-9 · Cited by 222
Self-citationFully end-to-end deep-learning-based diagnosis of pancreatic tumors
Si, K., Xue, Y., Yu, X., Zhu, X., Li, Q., Gong, W., Liang, T., & Duan, S. (2021) · Theranostics · doi:10.7150/thno.52508 · Cited by 120
Cited by
Yao, L., Zhang, Z., Keles, E., Yazici, C., Tirkes, T., & Bagci, U. (2023) · Current Opinion in Gastroenterology · doi:10.1097/mog.0000000000000966 · Cited by 53
Artificial Intelligence in Pancreatic Imaging: A Systematic Review
Podină, N., Gheorghe, E. C., Constantin, A., Cazacu, I., Croitoru, V., Gheorghe, C., Balaban, D. V., Jinga, M., Țieranu, C. G., & Săftoiu, A. (2025) · United European Gastroenterology Journal · doi:10.1002/ueg2.12723 · Cited by 48
Marcinkiewicz, A. M., Buchwald, M., Shanbhag, A., Bednarski, B. P., Killekar, A., Miller, R. J. H., Builoff, V., Lemley, M., Berman, D. S., Dey, D., et al. (2024) · Radiology · doi:10.1148/radiol.240541 · Cited by 20
Metadata
- Authors
- Chen, P.-T., Wu, T., Wang, P., Chang, D., Liu, K.-L., Wu, M.-S., Roth, H. R., Lee, P.-C., Liao, W.-C., & Wang, W.
- Venue
- Radiology
- Published
- 2023-01
- Volume
- 306
- Issue
- 1
- Pages
- 172-182
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W4295435240
- Cited by
- 188
- References
- 8
- FWCI
- 11.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pancreatic Cancer Detection on CT Scans with Deep Learning: A Nationwide Population-based Study. https://app.cochat.ai/papers/10.1148/radiol.220152
- The paper
- Chen, P.-T., Wu, T., Wang, P., Chang, D., Liu, K.-L., Wu, M.-S., Roth, H. R., Lee, P.-C., Liao, W.-C., & Wang, W. (2023). Pancreatic Cancer Detection on CT Scans with Deep Learning: A Nationwide Population-based Study. Radiology. https://doi.org/10.1148/radiol.220152
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.