Automated cardiovascular magnetic resonance image analysis with fully convolutional networks
Open accessAbstract
BACKGROUND: Cardiovascular resonance (CMR) imaging is a standard imaging modality for assessing cardiovascular diseases (CVDs), the leading cause of death globally. CMR enables accurate quantification of the cardiac chamber volume, ejection fraction and myocardial mass, providing information for diagnosis and monitoring of CVDs. However, for years, clinicians have been relying on manual approaches for CMR image analysis, which is time consuming and prone to subjective errors. It is a major clinical challenge to automatically derive quantitative and clinically relevant information from CMR images. METHODS: Deep neural networks have shown a great potential in image pattern recognition and segmentation for a variety of tasks. Here we demonstrate an automated analysis method for CMR images, which is based on a fully convolutional network (FCN). The network is trained and evaluated on a large-scale dataset from the UK Biobank, consisting of 4,875 subjects with 93,500 pixelwise annotated images. The performance of the method has been evaluated using a number of technical metrics, including the Dice metric, mean contour distance and Hausdorff distance, as well as clinically relevant measures, including left ventricle (LV) end-diastolic volume (LVEDV) and end-systolic volume (LVESV), LV mass (LVM); right ventricle (RV) end-diastolic volume (RVEDV) and end-systolic volume (RVESV). RESULTS: By combining FCN with a large-scale annotated dataset, the proposed automated method achieves a high performance in segmenting the LV and RV on short-axis CMR images and the left atrium (LA) and right atrium (RA) on long-axis CMR images. On a short-axis image test set of 600 subjects, it achieves an average Dice metric of 0.94 for the LV cavity, 0.88 for the LV myocardium and 0.90 for the RV cavity. The mean absolute difference between automated measurement and manual measurement is 6.1 mL for LVEDV, 5.3 mL for LVESV, 6.9 gram for LVM, 8.5 mL for RVEDV and 7.2 mL for RVESV. On long-axis image test sets, the average Dice metric is 0.93 for the LA cavity (2-chamber view), 0.95 for the LA cavity (4-chamber view) and 0.96 for the RA cavity (4-chamber view). The performance is comparable to human inter-observer variability. CONCLUSIONS: We show that an automated method achieves a performance on par with human experts in analysing CMR images and deriving clinically relevant measures.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
AI has been applied in various domains of healthcare including cancer research, cardiology, diabetes, mental health, identification of prognosis, Alzheimer's disease, identification of difference in clinical groups, cardiovascular disease, and stroke-related studies.
“AI has been put in application in various domains of healthcare [83–87] which includes cancer research [88], cardiology [89], diabetes [90], mental health [91], identification of prognosis [92], identification of Alzheimer's disease [93], identification of difference in the clinical groups [94], identification of cardiovascular disease [39], stroke-related studies [95], etc.”
From Applications of Artificial Intelligence and Big Data Analytics in m-Health: A Healthcare System Perspective (2020) · cites this paper as [85]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474 · see citing works
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404 · see citing works
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946 · see citing works
Delving Deep into Rectifiers: Surpassing Human-Level Performance on ImageNet Classification
He, K., Zhang, X., Ren, S., & Sun, J. (2015) · 2015 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2015.123 · Cited by 19,741 · see citing works
Dermatologist-level classification of skin cancer with deep neural networks
Esteva, A., Kuprel, B., Novoa, R. A., Ko, J., Swetter, S. M., Blau, H. M., & Thrun, S. (2017) · Nature · doi:10.1038/nature21056 · Cited by 14,362 · see citing works
ESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure 2012
Authors/Task Force Members, McMurray, J. J. V., Adamopoulos, S., Anker, S. D., Auricchio, A., Böhm, M., Dickstein, K., Falk, V., Filippatos, G., Fonseca, C., et al. (2012) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfs105 · Cited by 2,644 · see citing works
Deep Learning: A Critical Appraisal
Marcus, G. (2018) · arXiv · doi:10.48550/arxiv.1801.00631 · Cited by 853 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Attention gated networks: learning to leverage salient regions in medical images
Schlemper, J., Oktay, O., Schaap, M., Heinrich, M., Kainz, B., Glocker, B., & Rueckert, D. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.01.012 · Cited by 2,014 · see citing works
Self-citationLittlejohns, T. J., Holliday, J., Gibson, L. M., Garratt, S., Oesingmann, N., Alfaro-Almagro, F., Bell, J. D., Boultwood, C., Collins, R., Conroy, M. C., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-15948-9 · Cited by 812 · see citing works
Self-citationMulti-Centre, Multi-Vendor and Multi-Disease Cardiac Segmentation: The M&Ms Challenge
Campello, V. M., Gkontra, P., Izquierdo, C., Martin-Isla, C., Sojoudi, A., Full, P. M., Maier-Hein, K., Zhang, Y., He, Z., Ma, J., et al. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3090082 · Cited by 481 · see citing works
Self-citationDuan, J., Bello, G., Schlemper, J., Bai, W., Dawes, T. J. W., Biffi, C., de Marvao, A., Doumoud, G., O'Regan, D. P., & Rueckert, D. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2894322 · Cited by 227 · see citing works
Self-citationkhan, Z. F., & Alotaibi, S. R. (2020) · Journal of Healthcare Engineering · doi:10.1155/2020/8894694 · Cited by 235 · see citing works
Machine learning in the electrocardiogram
Mincholé, A., Camps, J., Lyon, A., & Rodríguez, B. (2019) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2019.08.008 · Cited by 147 · see citing works
Application of mobile health, telemedicine and artificial intelligence to echocardiography
Seetharam, K., Kagiyama, N., & Sengupta, P. P. (2019) · Echo Research & Practice · doi:10.1530/erp-18-0081 · Cited by 111 · see citing works
Puyol-Antón, E., Ruijsink, B., Mariscal Harana, J., Piechnik, S. K., Neubauer, S., Petersen, S. E., Razavi, R., Chowienczyk, P., & King, A. P. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.859310 · Cited by 85 · see citing works
Self-citationWeikert, T., Francone, M., Abbara, S., Baessler, B., Choi, B. W., Gutberlet, M., Hecht, E. M., Loewe, C., Mousseaux, E., Natale, L., et al. (2021) · European Radiology · doi:10.1007/s00330-020-07417-0 · Cited by 34 · see citing works
Luo, G., Dong, S., Wang, W., Wang, K., Cao, S., Tam, C., Zhang, H., Howey, J., Ohorodnyk, P., & Li, S. (2020) · Medical Image Analysis · doi:10.1016/j.media.2019.101591 · Cited by 30 · see citing works
Zhao, X., Liu, M., Wu, S., Zhang, B., Burjoo, A., Yang, Y., & Xu, D. (2023) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-22-965 · Cited by 15 · see citing works
Efficient Model Monitoring for Quality Control in Cardiac Image Segmentation
Galati, F., & Zuluaga, M. A. (2021) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-78710-3_11 · Cited by 15 · see citing works
- Authors
- Bai, W., Sinclair, M., Tarroni, G., Oktay, O., Rajchl, M., Vaillant, G., Lee, A. M., Aung, N., Lukaschuk, E., Sanghvi, M. M., Zemrak, F., Fung, K., Paiva, J. M., Carapella, V., Kim, Y. J., Suzuki, H., Kainz, B., Matthews, P. M., Petersen, S. E., Piechnik, S. K., Neubauer, S., Glocker, B., & Rueckert, D.
- Affiliations
- Imperial College London (GB)
- Queen Mary University of London (GB)
- University of Oxford (GB)
- Corresponding author
- Bai, Wenjia
- ORCID
- Bai, Wenjia
- Sinclair, Matthew
- Tarroni, Giacomo
- Oktay, Ozan
- Rajchl, Martin
- Vaillant, Ghislain
- Lee, Aaron M.
- Aung, Nay
- Lukaschuk, Elena
- Sanghvi, Mihir M.
- Zemrak, Filip
- Fung, Kenneth
- Carapella, Valentina
- Kim, Young Jin
- Suzuki, Hideaki
- Kainz, Bernhard
- Matthews, Paul M.
- Petersen, Steffen E.
- Piechnik, Stefan K.
- Neubauer, Stefan
- Glocker, Ben
- Rueckert, Daniel
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2018-02
- Volume
- 20
- Issue
- 1
- Pages
- 65
- ISSN
- 1097-6647 (ISSN-L)
- PMC
- PMC6138894
- OpenAlex
- W2803176574
- Cited by
- 773
- References
- 7
- Citations by year
- 2026: 87 · 2025: 100 · 2024: 80 · 2023: 107 · 2022: 111 · 2021: 113 · 2020: 96 · 2019: 69 · 2018: 10
- FWCI
- 36.01
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Journal of Cardiovascular Magnetic Resonance (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- City Research Online (City University London) (acceptedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Queen Mary Research Online (Queen Mary University of London) (submittedVersion, cc-by)
- Spiral (Imperial College London) (submittedVersion, other-oa)
- Funders
- Engineering and Physical Sciences Research Council (EP/P001009/1)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- cardiovascular magnetic resonance, fully convolutional network, cardiac image segmentation, left ventricle, right ventricle, left atrium, right atrium, ejection fraction, myocardial mass, UK Biobank, automated image analysis, interobserver variability, myocardium segmentation, left ventricular end-diastolic volume
- MeSH terms
- Deep Learning, Aged, Automation, Female, Heart Diseases, Humans, Image Interpretation, Computer-Assisted, Male, Middle Aged, Myocardial Contraction, Predictive Value of Tests, Stroke Volume, Reproducibility of Results, Observer Variation, Databases, Factual, Ventricular Function, Left, Ventricular Function, Right, Neural Networks, Computer, Magnetic Resonance Imaging, Cine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review