Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 173

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Radiologist Performance in the Diagnosis of Internal Hernia by Using Specific CT Findings with Emphasis on Transmesenteric Hernia

Blachar, Arye, Federle, Michael P., Brancatelli, Giuseppe, Peterson, Mark S., Oliver, James H., Li, Wei · 2001 · Radiology

Abstract

PURPOSE: To evaluate the performance of radiologists in the diagnosis of internal hernia with specific computed tomographic (CT) findings. MATERIALS AND METHODS: Abdominal CT scans obtained in 42 patients were retrospectively reviewed by three radiologists. The case group consisted of 18 patients with internal hernias (two paraduodenal, 16 transmesenteric); the comparison group was 24 patients with no internal hernia. Images were reviewed in a random and blinded fashion. Individual and group performance was evaluated with receiver operating characteristic (ROC) analysis, and interobserver agreement was measured with Cronbach coefficient alpha. Individual CT signs relevant as predictors of transmesenteric hernia were identified with logistic regression analysis and ranked by their odds ratio and P values. RESULTS: Both paraduodenal hernias were diagnosed by all readers on the basis of CT signs, including a retrogastric saclike mass of small-bowel loops. Diagnosis of transmesenteric hernia was more difficult and variable, with an average accuracy of area under the ROC curve (A(z)) of 77%, sensitivity of 63%, and specificity of 76%. CT signs of transmesenteric hernia were recognized consistently (Cronbach coefficient alpha >or= 0.80) and included a cluster of dilated small-bowel segments and stretching and displacement of mesenteric vessels. Coexisting volvulus and ischemia were diagnosed with low sensitivity (46% and 43%, respectively) but high specificity (96% and 98%, respectively). CONCLUSION: Diagnosis of internal hernia with CT remains difficult. Special attention should be given to the clustering of bowel loops, the mesenteric vessels, and signs of small-bowel obstruction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2212010126

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 173

Metadata

Authors
Blachar, A., Federle, M. P., Brancatelli, G., Peterson, M. S., Oliver, J. H., & Li, W.
Venue
Radiology
Published
2001-11
Volume
221
Issue
2
Pages
422-428
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2168338229
Cited by
173
References
2
FWCI
3.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Radiologist Performance in the Diagnosis of Internal Hernia by Using Specific CT Findings with Emphasis on Transmesenteric Hernia. https://app.cochat.ai/papers/10.1148/radiol.2212010126
The paper
Blachar, A., Federle, M. P., Brancatelli, G., Peterson, M. S., Oliver, J. H., & Li, W. (2001). Radiologist Performance in the Diagnosis of Internal Hernia by Using Specific CT Findings with Emphasis on Transmesenteric Hernia. Radiology. https://doi.org/10.1148/radiol.2212010126

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.