Patient Exposure from Radiologic and Nuclear Medicine Procedures in the United States and Worldwide: 2009–2018
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The U.S. National Council on Radiation Protection and Measurements (NCRP) conducted a retrospective assessment of the U.S. data, and the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) performed a similar worldwide assessment for 2009-2018 (with most data from 2014 to 2017). Using the data from those reports, the frequency of radiologic and nuclear medicine studies, annual collective, and per capita effective dose in the United States for 2016 were compared with worldwide estimates from 2009 to 2018. There were an estimated 691 million radiologic, CT, dental, and nuclear medicine studies performed in the United States in 2016, which represented 16.5% of the 4.2 billion performed worldwide. The United States also accounted for 74 million CT procedures (18% of the world's estimated total), 275 million conventional radiology procedures (11% of the world's total), 8.1 million interventional radiologic procedures (34% of the world's total), 320 million dental radiography procedures (29% of the world's total), and 13.5 million nuclear medicine procedures (34% of the world's total). The U.S. collective effective dose was 717 000 person-sieverts (17.6% of the world's total). The average annual individual effective dose in the United States was 2.2 mSv compared with 0.56 mSv worldwide. The United States accounts for a large and disproportionate share of global medical radiation procedures and collective effective dose, but use of CT has increased more in other countries compared with the United States.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preface, Executive Summary and Glossary
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.10.003 · Cited by 2,106
Cited by
Projected Lifetime Cancer Risks From Current Computed Tomography Imaging
Smith-Bindman, R., Chu, P. W., Azman Firdaus, H., Stewart, C., Malekhedayat, M., Alber, S., Bolch, W. E., Mahendra, M., Berrington de González, A., & Miglioretti, D. L. (2025) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2025.0505 · Cited by 358
Naghavi, M., Reeves, A. P., Atlas, K., Zhang, C., Atlas, T., Henschke, C. I., Yankelevitz, D. F., Budoff, M. J., Li, D., Roy, S. K., et al. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01308-0 · Cited by 45
“TheAIapproach can enable automatic screening of the over 10 million chest CT scans done each year in the US alone 23 .”
BackgroundGennari, A. G., Rossi, A., De Cecco, C. N., van Assen, M., Sartoretti, T., Giannopoulos, A. A., Schwyzer, M., Huellner, M. W., & Messerli, M. (2024) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-024-03080-4 · Cited by 16
“The discrepancies between the number of chest CT (~ 12,7 million), PET/CT (~ 1,8 million), and ECG-gated CACS scans (~ 57,500) acquired in the United States [111] high-light the potential to diagnose/refine the ASCVD risk in a wider population [112].”
BackgroundRapid patient-specific neural networks for intraoperative X-ray to volume registration
Gopalakrishnan, V., Chlorogiannis, D.-D., Abumoussa, A., Larson, A. M., Haouchine, N., Orbach, D. B., Frisken, S., Dey, N., & Golland, P. (2025) · arXiv · doi:10.48550/arxiv.2503.16309 · Cited by 13
“Each year, millions of clinical interventions are performed us-ing real-time X-ray image guidance ( i.e ., fluoroscopy) [1].”
Metadata
- Authors
- Mahesh, M., Ansari, A. J., & Mettler, F. A.
- Venue
- Radiology
- Published
- 2023-04-01
- Volume
- 307
- Issue
- 1
- Pages
- e221263-e221263
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W4311243826
- Cited by
- 127
- References
- 1
- FWCI
- 12.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.