Soft-Copy Mammographic Readings with Different Computer-assisted Detection Cuing Environments: Preliminary Findings
The DOI matches its Crossref record.
Abstract
PURPOSE: To assess the performance of radiologists in the detection of masses and microcalcification clusters on digitized mammograms by using different computer-assisted detection (CAD) cuing environments. MATERIALS AND METHODS: Two hundred nine digitized mammograms depicting 57 verified masses and 38 microcalcification clusters in 85 positive and 35 negative cases were interpreted independently by seven radiologists using five display modes. Except for the first mode, for which no CAD results were provided, suspicious regions identified with a CAD scheme were cued in all the other modes by using a combination of two cuing sensitivities (90% and 50%) and two false-positive rates (0.5 and 2.0 per image). A receiver operating characteristic study was performed by using soft-copy images. RESULTS: CAD cuing at 90% sensitivity and a rate of 0.5 false-positive region per image improved observer performance levels significantly (P < .01). As accuracy of CAD cuing decreased so did observer performances (P < .01). Cuing specificity affected mass detection more significantly, while cuing sensitivity affected detection of microcalcification clusters more significantly (P < .01). Reduction of cuing sensitivity and specificity significantly increased false-negative rates in noncued areas (P < .05). Trends were consistent for all observers. CONCLUSION: CAD systems have the potential to significantly improve diagnostic performance in mammography. However, poorly performing schemes could adversely affect observer performance in both cued and noncued areas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Automation bias: a systematic review of frequency, effect mediators, and mitigators
Goddard, K., Roudsari, A., & Wyatt, J. C. (2012) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2011-000089 · Cited by 1,162
American Cancer Society Guidelines for Breast Cancer Screening: Update 2003
Smith, R. A., Saslow, D., Andrews Sawyer, K., Burke, W., Costanza, M. E., Evans, W. P., Foster, R. S., Hendrick, E., Eyre, H. J., & Sener, S. (2003) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.53.3.141 · Cited by 770
Computer-Aided Detection and Diagnosis in Mammography
Sampat, M. P., Markey, M. K., & Bovik, A. C. (2005) · Handbook of Image and Video Processing · doi:10.1016/b978-012119792-6/50130-3 · Cited by 302
Rubin, G. D., Lyo, J. K., Paik, D. S., Sherbondy, A. J., Chow, L. C., Leung, A. N., Mindelzun, R., Schraedley-Desmond, P. K., Zinck, S. E., Naidich, D. P., et al. (2005) · Radiology · doi:10.1148/radiol.2341040589 · Cited by 259
Povyakalo, A. A., Alberdi, E., Strigini, L., & Ayton, P. (2013) · Medical Decision Making · doi:10.1177/0272989x12465490 · Cited by 79
“In these studies, radiologists proved significantly less sensitive with CAD than without, suggesting that incorrect CAD prompts may hinder readers under some circumstances, which is consistent with the findings of Zheng and others.(18) Our further analyses of data from Taylor and others(6) suggested that CAD reduced r…”
ResultImproving the radiologist-CAD interaction: designing for appropriate trust
Jorritsma, W., Cnossen, F., & van Ooijen, P. M. A. (2015) · Clinical Radiology · doi:10.1016/j.crad.2014.09.017 · Cited by 61
Rezazade Mehrizi, M. H., Mol, F., Peter, M., Ranschaert, E., Dos Santos, D. P., Shahidi, R., Fatehi, M., & Dratsch, T. (2023) · Scientific Reports · doi:10.1038/s41598-023-36435-3 · Cited by 54
Nishikawa, R. M., & Bae, K. T. (2018) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2017.08.027 · Cited by 44
“This may explain the findings of Wolfe et al [4, 5] and Zheng et al. [6] When using CAD as the first or concurrent reader, it likely enforces a radiologist’s fast automatic system 1 thinking and turns off the controlled process of system 2 thinking.”
BackgroundResult
Metadata
- Authors
- Zheng, B., Ganott, M. A., Britton, C. A., Hakim, C. M., Hardesty, L. A., Chang, T. S., Rockette, H. E., & Gur, D.
- Venue
- Radiology
- Published
- 2001-12
- Volume
- 221
- Issue
- 3
- Pages
- 633-640
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2152522287
- Cited by
- 97
- References
- 0
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.