Superparamagnetic Iron Oxide–enhanced MR Imaging of Head and Neck Lymph Nodes
The DOI matches its Crossref record.
Abstract
PURPOSE: To compare findings on superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) images of the head and neck with those from resected lymph node specimens and to determine the effect of such imaging on surgical planning in patients with histopathologically proved squamous cell carcinoma of the head and neck. MATERIALS AND METHODS: Thirty patients underwent MR imaging with nonenhanced and SPIO-enhanced (2.6 mg Fe/kg intravenously) T1-weighted (500/15 [repetition time msec/echo time msec]) and T2-weighted (1,900/80) spin-echo and T2-weighted gradient-echo (GRE) (500/15, 15 degrees flip angle) sequences. Signal intensity decrease was measured, and visual analysis was performed. Surgical plans were modified, if necessary, according to MR findings. Histopathologic and MR findings were compared. RESULTS: Histopathologic evaluation of 1,029 lymph nodes revealed 69 were metastatic. MR imaging enabled detection of 59 metastases. Regarding lymph node levels, MR diagnosis was correct in 26 of 27 patients who underwent surgery: Only one metastasis was localized in level II with MR imaging, whereas histopathologic evaluation placed it at level III. Extent of surgery was changed in seven patients. SPIO-enhanced T2-weighted GRE was the best sequence for differentiating between benign and malignant lymph nodes. CONCLUSION: SPIO-enhanced MR imaging has an important effect on planning the extent of surgery. On a patient basis, SPIO-enhanced MR images compared well with resected specimens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications
Dadfar, S. M., Roemhild, K., Drude, N. I., von Stillfried, S., Knüchel, R., Kiessling, F., & Lammers, T. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.01.005 · Cited by 1,181
Superparamagnetic Iron Oxide Nanoparticle Probes for Molecular Imaging
Thorek, D. L. J., Chen, A. K., Czupryna, J., & Tsourkas, A. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9002-7 · Cited by 772
Clinical Translation of Nanomedicine
Min, Y., Caster, J. M., Eblan, M. J., & Wang, A. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00116 · Cited by 772
Frank, J. A., Miller, B. R., Arbab, A. S., Zywicke, H. A., Jordan, E. K., Lewis, B. K., Bryant, L. H., & Bulte, J. W. M. (2003) · Radiology · doi:10.1148/radiol.2281020638 · Cited by 643
Nanoplatforms for Targeted Molecular Imaging in Living Subjects
Cai, W., & Chen, X. (2007) · Small · doi:10.1002/smll.200700351 · Cited by 563
Classification and basic properties of contrast agents for magnetic resonance imaging
Geraldes, C. F. G. C., & Laurent, S. (2009) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.265 · Cited by 541
Head and Neck Squamous Cell Carcinoma: Value of Diffusion-weighted MR Imaging for Nodal Staging
Vandecaveye, V., De Keyzer, F., Vander Poorten, V., Dirix, P., Verbeken, E., Nuyts, S., & Hermans, R. (2009) · Radiology · doi:10.1148/radiol.2511080128 · Cited by 340
Towards clinically translatable in vivo nanodiagnostics
Park, S.-M., Aalipour, A., Vermesh, O., Yu, J. H., & Gambhir, S. S. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.14 · Cited by 327
Sironi, S., Buda, A., Picchio, M., Perego, P., Moreni, R., Pellegrino, A., Colombo, M., Mangioni, C., Messa, C., & Fazio, F. (2006) · Radiology · doi:10.1148/radiol.2381041799 · Cited by 315
Heesakkers, R. A., Hövels, A. M., Jager, G. J., van den Bosch, H. C., Witjes, J. A., Raat, H. P., Severens, J. L., Adang, E. M., van der Kaa, C. H., Fütterer, J. J., et al. (2008) · The Lancet Oncology · doi:10.1016/s1470-2045(08)70203-1 · Cited by 307
Evaluation of lymph nodes with RECIST 1.1
Schwartz, L. H., Bogaerts, J., Ford, R., Shankar, L., Therasse, P., Gwyther, S., & Eisenhauer, E. A. (2009) · European Journal of Cancer · doi:10.1016/j.ejca.2008.10.028 · Cited by 298
Diagnostic precision of nanoparticle-enhanced MRI for lymph-node metastases: a meta-analysis
Will, O., Purkayastha, S., Chan, C., Athanasiou, T., Darzi, A. W., Gedroyc, W., & Tekkis, P. P. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(05)70537-4 · Cited by 260
Koh, D.-M., Brown, G., Temple, L., Raja, A., Toomey, P., Bett, N., Norman, A. R., & Husband, J. E. (2004) · Radiology · doi:10.1148/radiol.2311030142 · Cited by 258
Nanoparticles for Imaging: top or Flop?
Kiessling, F., Mertens, M. E., Grimm, J., & Lammers, T. (2014) · Radiology · doi:10.1148/radiol.14131520 · Cited by 228
New developments in MRI for target volume delineation in radiotherapy
Khoo, V. S., & Joon, D. L. (2006) · The British Journal of Radiology · doi:10.1259/bjr/41321492 · Cited by 207
Positron emission imaging of head and neck cancer, including thyroid carcinoma
Schöder, H., & Yeung, H. W. D. (2004) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2004.03.004 · Cited by 176
Metadata
- Authors
- Mack, M. G., Balzer, J. O., Straub, R., Eichler, K., & Vogl, T. J.
- Venue
- Radiology
- Published
- 2002-01
- Volume
- 222
- Issue
- 1
- Pages
- 239-244
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2107457318
- Cited by
- 167
- References
- 0
- FWCI
- 8.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.