The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Clinically Applicable Labeling of Mammalian and Stem Cells by Combining Superparamagnetic Iron Oxides and Transfection Agents
Abstract
PURPOSE: To label mammalian and stem cells by combining commercially available transfection agents (TAs) with superparamagnetic iron oxide (SPIO) magnetic resonance (MR) imaging contrast agents. MATERIALS AND METHODS: Three TAs were incubated with ferumoxides and MION-46L in cell culture medium at various concentrations. Human mesenchymal stem cells, mouse lymphocytes, rat oligodendrocyte progenitor CG-4 cells, and human cervical carcinoma cells were incubated 2-48 hours with 25 microg of iron per milliliter of combined TAs and SPIO. Cellular labeling was evaluated with T2 relaxometry, MR imaging of labeled cell suspensions, and Prussian blue staining for iron assessment. Proliferation and viability of mesenchymal stem cells and human cervical carcinoma cells labeled with a combination of TAs and ferumoxides were evaluated. RESULTS: When ferumoxides-TA or MION-46L-TA was used, intracytoplasmic particles stained with Prussian blue stain were detected for all cell lines with a labeling efficiency of nearly 100%. Limited or no uptake was observed for cells incubated with ferumoxides or MION-46L alone. For TA-SPIO-labeled cells, MR images and relaxometry findings showed a 50%-90% decrease in signal intensity and a more than 40-fold increase in T2s. Cell viability varied from 103.7% +/- 9 to 123.0% +/- 9 compared with control cell viability at 9 days, and cell proliferation was not affected by endosomal incorporation of SPIO nanoparticles. Iron concentrations varied with ferumoxides-TA combinations and cells with a maximum of 30.1 pg +/- 3.7 of iron per cell for labeled mesenchymal stem cells. CONCLUSION: Magnetic labeling of mammalian cells with use of ferumoxides and TAs is possible and may enable cellular MR imaging and tracking in experimental and clinical settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilineage potential of adult human mesenchymal stem cells
Pittenger, M. F., Mackay, A. M., Beck, S. C., Jaiswal, R. K., Douglas, R., Mosca, J. D., Moorman, M. A., Simonetti, D. W., Craig, S., & Marshak, D. R. (1999) · Science · doi:10.1126/science.284.5411.143 · Cited by 21,052
Cited by
Iron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500
Self-citationIn Vivo Magnetic Resonance Imaging of Mesenchymal Stem Cells in Myocardial Infarction
Kraitchman, D. L., Heldman, A. W., Atalar, E., Amado, L. C., Martin, B. J., Pittenger, M. F., Hare, J. M., & Bulte, J. W. M. (2003) · Circulation · doi:10.1161/01.cir.0000070931.62772.4e · Cited by 710
Self-citationVillaraza, A. J. L., Bumb, A., & Brechbiel, M. W. (2010) · Chemical Reviews · doi:10.1021/cr900232t · Cited by 632
In vivo MRI cell tracking: clinical studies
Bulte, J. W. M. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.3107 · Cited by 430
Self-citationArbab, A. S., Yocum, G. T., Rad, A. M., Khakoo, A. Y., Fellowes, V., Read, E. J., & Frank, J. A. (2005) · NMR in Biomedicine · doi:10.1002/nbm.991 · Cited by 297
Self-citation
Metadata
- Authors
- Frank, J. A., Miller, B. R., Arbab, A. S., Zywicke, H. A., Jordan, E. K., Lewis, B. K., Bryant, L. H., & Bulte, J. W. M.
- Venue
- Radiology
- Published
- 2003-08
- Volume
- 228
- Issue
- 2
- Pages
- 480-487
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2121045793
- Cited by
- 643
- References
- 1
- FWCI
- 33.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinically Applicable Labeling of Mammalian and Stem Cells by Combining Superparamagnetic Iron Oxides and Transfection Agents. https://app.cochat.ai/papers/10.1148/radiol.2281020638
- The paper
- Frank, J. A., Miller, B. R., Arbab, A. S., Zywicke, H. A., Jordan, E. K., Lewis, B. K., Bryant, L. H., & Bulte, J. W. M. (2003). Clinically Applicable Labeling of Mammalian and Stem Cells by Combining Superparamagnetic Iron Oxides and Transfection Agents. Radiology. https://doi.org/10.1148/radiol.2281020638
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).