Contrast-enhanced Blood-Pool MR Angiography with Optimized Iron Oxides: Effect of Size and Dose on Vascular Contrast Enhancement in Rabbits
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: To investigate intravascular enhancement of bolus-injectable small and ultrasmall superparamagnetic iron oxides (USPIOs) of different particle sizes and relaxivities for first-pass and blood-pool magnetic resonance (MR) angiography. MATERIALS AND METHODS: Iron oxides with different particle sizes (hydrodynamic diameters, 21, 33, 46, and 65 nm) were bolus injected intravenously at three doses (10, 20, and 40 micromol per kilogram body weight). An extracellular contrast agent (gadopentetate dimeglumine) served as a control. MR angiography was performed multiple times after intravenous injection (5-120 minutes and 24 hours later). Signal enhancement was calculated from signal intensity measurements in the abdominal aorta and renal and iliac arteries. RESULTS: Highest enhancement was seen during the first pass with all contrast agents. USPIO enhancement in the abdominal aorta increased significantly with decreasing particle size (65 nm vs 33 nm, 65 nm vs 21 nm; P <.01). CONCLUSION: The smallest iron oxide provided signal enhancement comparable with that of gadopentetate dimeglumine at 40 micromol iron per kilogram for first-pass investigations, with prolonged signal enhancement up to 25 minutes, allowing multiple measurements after injection of a single bolus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hamm, B., Staks, T., Taupitz, M., Maibauer, R., Speidel, A., Huppertz, A., Frenzel, T., Lawaczeck, R., Wolf, K. J., & Lange, L. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040508 · Cited by 187
Liver MR imaging with iron oxides: toward consensus and clinical practice
Weissleder, R. (1994) · Radiology · doi:10.1148/radiology.193.3.7972790 · Cited by 101 · cited 1×
“However, iron oxide preparations such as AMI-25 and AMI-227 may not be bolus injectable because of cardiovascular side effects and lumbar pain, and MION-37 and MION-46 preparations have been tested in only animal models so far (8,43).”
Background
Cited by
Kim, B. H., Lee, N., Kim, H., An, K., Park, Y. I., Choi, Y., Shin, K., Lee, Y., Kwon, S. G., Na, H. B., et al. (2011) · Journal of the American Chemical Society · doi:10.1021/ja203340u · Cited by 947
Reimer, P., & Balzer, T. (2003) · European Radiology · doi:10.1007/s00330-002-1721-7 · Cited by 614
Self-citationInteractions of nanomaterials and biological systems: Implications to personalized nanomedicine
Zhang, X.-Q., Xu, X., Bertrand, N., Pridgen, E., Swami, A., & Farokhzad, O. C. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.08.005 · Cited by 487
Sandiford, L., Phinikaridou, A., Protti, A., Meszaros, L. K., Cui, X., Yan, Y., Frodsham, G., Williamson, P. A., Gaddum, N., Botnar, R. M., et al. (2013) · ACS Nano · doi:10.1021/nn3046055 · Cited by 268
Nanoparticles as Computed Tomography Contrast Agents: Current Status and Future Perspectives
Shilo, M., Reuveni, T., Motiei, M., & Popovtzer, R. (2012) · Nanomedicine · doi:10.2217/nnm.11.190 · Cited by 238
Metadata
- Authors
- Allkemper, T., Bremer, C., Matuszewski, L., Ebert, W., & Reimer, P.
- Venue
- Radiology
- Published
- 2002-05
- Volume
- 223
- Issue
- 2
- Pages
- 432-438
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2109041633
- Cited by
- 124
- References
- 2
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.