The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Coronary Artery Calcium: Absolute Quantification in Nonenhanced and Contrast-enhanced Multi–Detector Row CT Studies
Abstract
PURPOSE: (a) To determine the accuracy of multi-detector row computed tomography (CT) in the measurement of the calcium concentration in a cardiac CT calibration phantom and (b) to assess the correlation of a traditional 3-mm section width CT coronary screening protocol and a 1.25-mm section width CT angiography imaging protocol in the quantification of the absolute mass of coronary calcium in patients who underwent both coronary screening and CT angiography with a multi-detector row CT scanner. MATERIALS AND METHODS: A heart phantom containing calcified cylinders was scanned to determine calibration factors and absolute calcium mass. In 50 patients, the variability (value 1 - value 2/mean value 1 - value 2), limit of agreement (+/-2SD value 1 - value 2), and systematic error (mean value 1 - value 2) of the total amount of coronary calcium calculated at traditional 3-mm section width CT and at 1.25-mm section width CT angiography were determined. RESULTS: The correlation coefficient between the 3-mm section width, nonenhanced protocol and the 1.25-mm section width CT angiography protocol was very high (r = 0.977) and the mean variability was low (19.7%) for the absolute mass. There was a systematic error of -6.7 mg and a limit of agreement between 45.0 mg and -58.5 mg. CONCLUSION: Use of the mass quantification algorithm in combination with a calibration phantom allows accurate quantification of coronary calcium. Measurements of calcium mass obtained at 1.25-mm section width CT angiography have the best agreement with those obtained at the traditional 3-mm section width imaging protocol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786
Cited by
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Leipsic, J., Abbara, S., Achenbach, S., Cury, R., Earls, J. P., Mancini, G. J., Nieman, K., Pontone, G., & Raff, G. L. (2014) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2014.07.003 · Cited by 1,072
SCCT guidelines for the interpretation and reporting of coronary computed tomographic angiography
Raff, G. L., Chair, Abidov, A., Achenbach, S., Berman, D. S., Boxt, L. M., Budoff, M. J., Cheng, V., DeFrance, T., Hellinger, J. C., et al. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.01.001 · Cited by 773
Atherothrombosis and High-Risk Plaque
Fuster, V., Moreno, P. R., Fayad, Z. A., Corti, R., & Badimon, J. J. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.074 · Cited by 738
Diagnostic and Prognostic Value of Absence of Coronary Artery Calcification
Sarwar, A., Shaw, L. J., Shapiro, M. D., Blankstein, R., Hoffman, U., Cury, R. C., Abbara, S., Brady, T. J., Budoff, M. J., Blumenthal, R. S., et al. (2009) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2008.12.031 · Cited by 679
Metadata
- Authors
- Hong, C., Becker, C. R., Schoepf, U. J., Ohnesorge, B., Bruening, R., & Reiser, M. F.
- Venue
- Radiology
- Published
- 2002-05
- Volume
- 223
- Issue
- 2
- Pages
- 474-480
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2128372758
- Cited by
- 193
- References
- 2
- FWCI
- 16.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coronary Artery Calcium: Absolute Quantification in Nonenhanced and Contrast-enhanced Multi–Detector Row CT Studies. https://app.cochat.ai/papers/10.1148/radiol.2232010919
- The paper
- Hong, C., Becker, C. R., Schoepf, U. J., Ohnesorge, B., Bruening, R., & Reiser, M. F. (2002). Coronary Artery Calcium: Absolute Quantification in Nonenhanced and Contrast-enhanced Multi–Detector Row CT Studies. Radiology. https://doi.org/10.1148/radiol.2232010919
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.