Peritoneal Metastases: Detection with Spiral CT in Patients with Ovarian Cancer
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
PURPOSE: To determine the accuracy of spiral computed tomography (CT) in the depiction of peritoneal metastases by using surgical findings in patients with ovarian cancer as the standard of reference. MATERIALS AND METHODS: Three independent readers reviewed the preoperative CT scans obtained in 64 patients who underwent primary surgery for ovarian cancer. Readers rated the likelihood of peritoneal metastases on a five-point scale and recorded the presence or absence of ascites, parietal peritoneal thickening or enhancement, and small-bowel wall thickening or distortion. Peritoneal metastases were identified as nodular, plaquelike, or infiltrative soft-tissue lesions in the peritoneal fat or on the peritoneal surface. Area under the receiver operating characteristic curve was calculated for each reader. Interreader agreement was evaluated with the kappa statistic. Descriptive statistical data were determined with dichotomized ratings (1-3 = absent; 4-5 = present). RESULTS: Areas under the receiver operating characteristic curves for the three readers were 0.95, 0.93, and 0.89. Paired kappa values ranged from 0.75 to 0.91. Reader sensitivity for metastases 1 cm or smaller in maximum diameter (25%-50%) was significantly (P <.05) lower than overall sensitivity (85%-93%). Ascites, parietal peritoneal thickening or enhancement, and small-bowel wall thickening or distortion demonstrated positive predictive values of 72%-93%, with kappa values of 0.12-0.80. CONCLUSION: Spiral CT is accurate in the depiction of peritoneal metastases from ovarian cancer, although sensitivity is reduced in patients with tumor implants 1 cm or smaller. Ancillary signs of peritoneal malignancy are limited by low interobserver agreement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Tempany, C. M. C., Zou, K. H., Silverman, S. G., Brown, D. L., Kurtz, A. B., & McNeil, B. J. (2000) · Radiology · doi:10.1148/radiology.215.3.r00jn25761 · Cited by 381
CT differentiation of tuberculous peritonitis and peritoneal carcinomatosis.
Ha, H. K., Jung, J. I., Lee, M. S., Choi, B. G., Lee, M. G., Kim, Y. H., Kim, P. N., & Auh, Y. H. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.167.3.8751693 · Cited by 194
Peritoneal implants from ovarian tumors: CT findings.
Buy, J. N., Moss, A. A., Ghossain, M. A., Sciot, C., Malbec, L., Vadrot, D., Paniel, B. J., & Decroix, Y. (1988) · Radiology · doi:10.1148/radiology.169.3.3186993 · Cited by 118
Low, R. N., Semelka, R. C., Worawattanakul, S., Alzate, G. D., & Sigeti, J. S. (1999) · Radiology · doi:10.1148/radiology.210.3.r99mr46625 · Cited by 93
Cited by
Koh, J.-L., Yan, T. D., Glenn, D., & Morris, D. L. (2009) · Annals of Surgical Oncology · doi:10.1245/s10434-008-0234-2 · Cited by 369
Sala, E., Rockall, A. G., Freeman, S. J., Mitchell, D. G., & Reinhold, C. (2013) · Radiology · doi:10.1148/radiol.12120315 · Cited by 347
de Bree, E., Koops, W., Kröger, R., van Ruth, S., Witkamp, A. J., & Zoetmulder, F. A. N. (2004) · Journal of Surgical Oncology · doi:10.1002/jso.20049 · Cited by 291
CA 125, PET alone, PET–CT, CT and MRI in diagnosing recurrent ovarian carcinoma
Gu, P., Pan, L.-L., Wu, S.-Q., Sun, L., & Huang, G. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.02.019 · Cited by 265
FDG-PET for management of cervical and ovarian cancer
Havrilesky, L. J., Kulasingam, S. L., Matchar, D. B., & Myers, E. R. (2005) · Gynecologic Oncology · doi:10.1016/j.ygyno.2004.12.007 · Cited by 253
Levy, A. D., Shaw, J. C., & Sobin, L. H. (2009) · RadioGraphics · doi:10.1148/rg.292085189 · Cited by 253
Michielsen, K., Vergote, I., Op de beeck, K., Amant, F., Leunen, K., Moerman, P., Deroose, C., Souverijns, G., Dymarkowski, S., De Keyzer, F., et al. (2014) · European Radiology · doi:10.1007/s00330-013-3083-8 · Cited by 237
Fujii, S., Matsusue, E., Kanasaki, Y., Kanamori, Y., Nakanishi, J., Sugihara, S., Kigawa, J., Terakawa, N., & Ogawa, T. (2008) · European Radiology · doi:10.1007/s00330-007-0732-9 · Cited by 220
“93% and 78–96%, respectively, on contrast-enhanced CT imaging [16, 17], and 95 and 80%, respectively, on contrast-enhanced MR imaging [18].”
BackgroundStaging of peritoneal carcinomatosis: enhanced CT vs. PET/CT
Dromain, C., Leboulleux, S., Auperin, A., Goere, D., Malka, D., Lumbroso, J., Schumberger, M., Sigal, R., & Elias, D. (2008) · Abdominal Imaging · doi:10.1007/s00261-007-9211-7 · Cited by 213
“[11] assessed the inter-reader agreement evaluated with the kappa statistic of three independent readers in the depiction of peritoneal carcinomatosis.”
MethodEsquivel, J., Chua, T. C., Stojadinovic, A., Melero, J. T., Levine, E. A., Gutman, M., Howard, R., Piso, P., Nissan, A., Gomez‐Portilla, A., et al. (2010) · Journal of Surgical Oncology · doi:10.1002/jso.21601 · Cited by 195
“However, its accuracy of identifying peritoneal metastases from gastrointestinal and gynecological malignancies by CT scan is low [11,12].”
Diagnostic performance of imaging for the detection of peritoneal metastases: a meta-analysis
van ’t Sant, I., Engbersen, M. P., Bhairosing, P. A., Lambregts, D. M. J., Beets-Tan, R. G. H., van Driel, W. J., Aalbers, A. G. J., Kok, N. F. M., & Lahaye, M. J. (2020) · European Radiology · doi:10.1007/s00330-019-06524-x · Cited by 173
Kitajima, K., Murakami, K., Yamasaki, E., Kaji, Y., Fukasawa, I., Inaba, N., & Sugimura, K. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0890-2 · Cited by 172
“Several early studies found that CT had an accuracy of 70–90% for preoperative staging of ovarian cancer [9] and a sensitivity of 63–92% and specificity of 82–96% for detection of peritoneal involvement [10, 12 ].”
BackgroundMethodMultidetector CT of Peritoneal Carcinomatosis from Ovarian Cancer
Pannu, H. K., Bristow, R. E., Montz, F. J., & Fishman, E. K. (2003) · RadioGraphics · doi:10.1148/rg.233025105 · Cited by 159
Metadata
- Authors
- Coakley, F. V., Choi, P. H., Gougoutas, C. A., Pothuri, B., Venkatraman, E., Chi, D., Bergman, A., & Hricak, H.
- Venue
- Radiology
- Published
- 2002-05
- Volume
- 223
- Issue
- 2
- Pages
- 495-499
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2137270859
- Cited by
- 342
- References
- 5
- FWCI
- 8.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.