Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 381

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Staging of Advanced Ovarian Cancer: Comparison of Imaging Modalities—Report from the Radiological Diagnostic Oncology Group

Tempany, Clare M. C., Zou, Kelly H., Silverman, Stuart G., Brown, Douglas L., Kurtz, Alfred B., McNeil, Barbara J.·2000·Radiology

Abstract

PURPOSE: To compare ultrasonography (US), magnetic resonance (MR) imaging, and computed tomography (CT) for diagnosing and staging advanced ovarian cancer. MATERIALS AND METHODS: US, CT, and MR imaging were performed in 280 patients. Images were read by three radiologists from each of the five hospitals. Image analysis included determination of malignancy within the peritoneum (11 sites), lymph nodes (10 sites), and hepatic parenchyma. The standard of reference was based on surgical and histopathologic findings. Statistical methods used were receiver operating characteristic (ROC) curve analysis, pairwise comparison of areas under the ROC curves (A(z)), analysis of sensitivity and specificity pairs, and assessment of agreement between the degree of suspicion and standard of reference. RESULTS: There were 118 patients with malignant tumors; 73 (62%) had stage III or IV disease. Metastases were found in the peritoneum in 70 (59%), nodes in 20 (17%), and liver in seven (6%) cases. In the peritoneum, MR imaging and CT (A(z) = 0.96 for both) were more accurate than US (A(z) = 0.86), especially in the subdiaphragmatic spaces and hepatic surfaces. MR imaging and CT were more sensitive than US (95%, 92%, and 69%, respectively) for peritoneal metastases. MR imaging was more accurate than CT for detection of lymph node metastases (A(z) = 0.76 vs 0.57, P =.04). In the liver, the A(z) values for the three modalities were 0.77-0.94. CONCLUSION: CT and MR imaging are equally accurate, and either modality can be used to stage advanced ovarian cancer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.215.3.r00jn25761

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 381

Metadata

Authors
Tempany, C. M. C., Zou, K. H., Silverman, S. G., Brown, D. L., Kurtz, A. B., & McNeil, B. J.
Venue
Radiology
Published
2000-06
Volume
215
Issue
3
Pages
761-767
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2027348031
Cited by
381
References
10
FWCI
7.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Staging of Advanced Ovarian Cancer: Comparison of Imaging Modalities—Report from the Radiological Diagnostic Oncology Group. https://app.cochat.ai/papers/10.1148/radiology.215.3.r00jn25761
The paper
Tempany, C. M. C., Zou, K. H., Silverman, S. G., Brown, D. L., Kurtz, A. B., & McNeil, B. J. (2000). Staging of Advanced Ovarian Cancer: Comparison of Imaging Modalities—Report from the Radiological Diagnostic Oncology Group. Radiology. https://doi.org/10.1148/radiology.215.3.r00jn25761

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.