Relative Cerebral Blood Volume Measurements in Intracranial Mass Lesions: Interobserver and Intraobserver Reproducibility Study
The DOI matches its Crossref record.
Abstract
PURPOSE: To assess inter- and intraobserver reproducibility for different techniques of measuring relative cerebral blood volume (rCBV) in patients with intracranial mass lesions. MATERIALS AND METHODS: Three independent observers (neuroradiology fellows) who were blinded to the histopathologic diagnosis performed rCBV measurements in 50 patients with various intracranial mass lesions. Three different methods were compared. With method 1, placement of a single region of interest was guided by a color overlay map. With methods 2 and 3, the highest rCBV value and the mean of repeated rCBV measurements, respectively, were recorded. Calculations of the intraclass correlation coefficient, coefficient of variation (CV), and descriptive statistics were used to determine the levels of reproducibility. A multiple linear regression model was used to evaluate for possible explanatory factors for interobserver variance. RESULTS: Method 2 had, overall, the best reproducibility of all techniques, with an intraclass interobserver correlation coefficient of 0.71 (indicating good agreement), interobserver CV of 30%, and intraobserver CV in the range of 32%-41%. Measurement variations between observers correlated significantly (P <.001) with increasing rCBV values. CONCLUSION: In this study, interobserver and intraobserver reproducibility of rCBV measurements were clinically acceptable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Applications and limitations of radiomics
Yip, S. S. F., & Aerts, H. J. W. L. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/13/r150 · Cited by 1,210
The Potential of Radiomic-Based Phenotyping in Precision Medicine: A Review
Aerts, H. J. W. L. (2016) · JAMA Oncology · doi:10.1001/jamaoncol.2016.2631 · Cited by 669
Law, M., Young, R. J., Babb, J. S., Peccerelli, N., Chheang, S., Gruber, M. L., Miller, D. C., Golfinos, J. G., Zagzag, D., & Johnson, G. (2008) · Radiology · doi:10.1148/radiol.2472070898 · Cited by 534
Self-citationProvenzale, J. M., Mukundan, S., & Barboriak, D. P. (2006) · Radiology · doi:10.1148/radiol.2393042031 · Cited by 402
Perfusion MRI: The Five Most Frequently Asked Clinical Questions
Essig, M., Nguyen, T. B., Shiroishi, M. S., Saake, M., Provenzale, J. M., Enterline, D. S., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9544 · Cited by 344
Self-citationImaging Angiogenesis: Applications and Potential for Drug Development
Miller, J. C., Pien, H. H., Sahani, D., Sorensen, A. G., & Thrall, J. H. (2005) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/dji023 · Cited by 325
Diagnostic performance of spectroscopic and perfusion MRI for distinction of brain tumors
Weber, M. A., Zoubaa, S., Schlieter, M., Jüttler, E., Huttner, H. B., Geletneky, K., Ittrich, C., Lichy, M. P., Kroll, A., Debus, J., et al. (2006) · Neurology · doi:10.1212/01.wnl.0000219767.49705.9c · Cited by 268
Perfusion and diffusion MR imaging in enhancing malignant cerebral tumors
Calli, C., Kitis, O., Yunten, N., Yurtseven, T., Islekel, S., & Akalin, T. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2005.12.032 · Cited by 263
Law, M., Saindane, A. M., Ge, Y., Babb, J. S., Johnson, G., Mannon, L. J., Herbert, J., & Grossman, R. I. (2004) · Radiology · doi:10.1148/radiol.2313030996 · Cited by 242
Self-citationPrager, A. J., Martinez, N., Beal, K., Omuro, A., Zhang, Z., & Young, R. J. (2015) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4218 · Cited by 193
“These techniques are rapid, reproducible, robust by using commercial software, and are commonly used in clinical practice.(17,18) Although some authors have implemented 3D volumetric measurements,(34) these tools often require additional technical expertise and are not widely available.”
MethodAdhya, S., Johnson, G., Herbert, J., Jaggi, H., Babb, J. S., Grossman, R. I., & Inglese, M. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.08.008 · Cited by 168
“To exclude inter-observer and minimize intra-observer variability as to the location of ROI placement between patients, each patient data set was reviewed by both authors at the same time (Wetzel et al., 2002).”
MethodSelf-citationHoefnagels, F. W. A., Lagerwaard, F. J., Sanchez, E., Haasbeek, C. J. A., Knol, D. L., Slotman, B. J., & Peter Vandertop, W. (2009) · Journal of Neurology · doi:10.1007/s00415-009-5034-5 · Cited by 168
“Since spatial heterogeneity is a possible confounding factor in recurrent lesions, rCBVs were calculated for the highest perfusion fraction, irrespective of whether that area was judged as being actually high relative to contralateral white or grey matter, in concordance with previous reports [24, 26, 55 ].”
ResultEmblem, K. E., Nedregaard, B., Nome, T., Due-Tonnessen, P., Hald, J. K., Scheie, D., Borota, O. C., Cvancarova, M., & Bjornerud, A. (2008) · Radiology · doi:10.1148/radiol.2473070571 · Cited by 159
Jones, J. G. A., Cen, S. Y., Lebel, R. M., Hsieh, P. C., & Law, M. (2013) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3199 · Cited by 157
“of 30% and 32%– 41%, respectively, have been reported for this technique.(24)”
BackgroundSelf-citationElshafeey, N., Kotrotsou, A., Hassan, A., Elshafei, N., Hassan, I., Ahmed, S., Abrol, S., Agarwal, A., El Salek, K., Bergamaschi, S., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-11007-0 · Cited by 147
Self-citationMcKinney, A. M., Benson, J., Nascene, D. R., Eisengart, J., Salmela, M. B., Loes, D. J., Zhang, L., Patel, K., Raymond, G. V., & Miller, W. P. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4773 · Cited by 12
Metadata
- Authors
- Wetzel, S. G., Cha, S., Johnson, G., Lee, P., Law, M., Kasow, D. L., Pierce, S. D., & Xue, X.
- Venue
- Radiology
- Published
- 2002-09
- Volume
- 224
- Issue
- 3
- Pages
- 797-803
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2101120359
- Cited by
- 246
- References
- 0
- FWCI
- 3.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.