CoChat

Aortic and Hepatic Enhancement and Tumor-to-Liver Contrast: Analysis of the Effect of Different Concentrations of Contrast Material at Multi–Detector Row Helical CT

Awai, Kazuo, Takada, Koichi, Onishi, Hiromitsu, Hori, Shinichi · 2002 · Radiology
Cited by 164

The DOI matches its Crossref record.

Abstract

PURPOSE: To investigate the effect of different iodine concentrations of contrast material on aortic and hepatic enhancement and the detectability of hypervascular hepatocellular carcinoma (HCC) with multi-detector row computed tomography (CT) and a uniphasic contrast material injection technique. MATERIALS AND METHODS: Two hundred one patients with known or who were suspected of having HCC underwent multi-detector row CT; 58 patients with hypervascular HCC were identified. First-, second-, and third-phase scanning was started with the aortic arrival times plus 15 seconds, plus 30 seconds, and plus 105 seconds, respectively. All patients were assigned randomly into two groups. Patients in groups A and B received iopamidol with an iodine concentration of 300 mg/mL and 370 mg/mL, respectively, with the same total iodine load per patient per body weight. The liver and aorta enhancement and tumor-to-liver contrast (TLC) were measured. Depiction of hepatic arteries was evaluated visually by two radiologists. RESULTS: During the first phase, aortic enhancement was significantly (P <.01) higher in group B, with no significant difference in hepatic enhancement between the two groups. During the second phase, aortic enhancement was significantly (P <.01) higher in group A, with no significant difference in hepatic enhancement. The TLC was significantly (P <.01) higher in group B during the first phase, but there was no significant difference between the two groups during the second phase. There was no significant difference in any parameters between the two groups during the third phase. Depiction of the hepatic arteries in group B was significantly (P <.05) superior to that in group A. CONCLUSION: In the arterial phase, administration of a higher concentration of contrast material is effective for a significantly higher TLC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2243011188

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 164

Metadata

Authors
Awai, K., Takada, K., Onishi, H., & Hori, S.
Venue
Radiology
Published
2002-09
Volume
224
Issue
3
Pages
757-763
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2101518997
Cited by
164
References
0
FWCI
7.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Aortic and Hepatic Enhancement and Tumor-to-Liver Contrast: Analysis of the Effect of Different Concentrations of Contrast Material at Multi–Detector Row Helical CT. https://app.cochat.ai/papers/10.1148/radiol.2243011188
The paper
Awai, K., Takada, K., Onishi, H., & Hori, S. (2002). Aortic and Hepatic Enhancement and Tumor-to-Liver Contrast: Analysis of the Effect of Different Concentrations of Contrast Material at Multi–Detector Row Helical CT. Radiology. https://doi.org/10.1148/radiol.2243011188

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.