The DOI matches its Crossref record.
Performance Parameters for Screening and Diagnostic Mammography: Specialist and General Radiologists
Abstract
PURPOSE: To evaluate performance parameters for radiologists in a practice of breast imaging specialists and general diagnostic radiologists who interpret a large series of consecutive screening and diagnostic mammographic studies. MATERIALS AND METHODS: Data (ie, patient age; family history of breast cancer; availability of previous mammograms for comparison; and abnormal interpretation, cancer detection, and stage 0-I cancer detection rates) were derived from review of mammographic studies obtained from January 1997 through August 2001. The breast imaging specialists have substantially more initial training in mammography and at least six times more continuing education in mammography, and they interpret 10 times more mammographic studies per year than the general radiologists. Differences between specialist and general radiologist performances at both screening and diagnostic examinations were assessed for significance by using Student t and chi(2) tests. RESULTS: The study involved 47,798 screening and 13,286 diagnostic mammographic examinations. Abnormal interpretation rates for screening mammography (ie, recall rate) were 4.9% for specialists and 7.1% for generalists (P <.001); and for diagnostic mammography (ie, recommended biopsy rate), 15.8% and 9.9%, respectively (P <.001). Cancer detection rates at screening mammography were 6.0 cancer cases per 1,000 examinations for specialists and 3.4 per 1,000 for generalists (P =.007); and at diagnostic mammography, 59.0 per 1,000 and 36.6 per 1,000, respectively (P <.001). Stage 0-I cancer detection rates at screening mammography were 5.3 cancer cases per 1,000 examinations for specialists and 3.0 per 1,000 for generalists (P =.012); and at diagnostic mammography, 43.9 per 1,000 and 27.0 per 1,000, respectively (P <.001). CONCLUSION: Specialist radiologists detect more cancers and more early-stage cancers, recommend more biopsies, and have lower recall rates than general radiologists.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287
Implementation of Breast Tomosynthesis in a Routine Screening Practice: An Observational Study
Rose, S. L., Tidwell, A. L., Bujnoch, L. J., Kushwaha, A. C., Nordmann, A. S., & Sexton, R. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9672 · Cited by 329
Comparison of Screening Mammography in the United States and the United Kingdom
Smith-Bindman, R. (2003) · JAMA · doi:10.1001/jama.290.16.2129 · Cited by 314
Gur, D., Sumkin, J. H., Rockette, H. E., Ganott, M., Hakim, C., Hardesty, L., Poller, W. R., Shah, R., & Wallace, L. (2004) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djh067 · Cited by 306
Newman, E. A., Guest, A. B., Helvie, M. A., Roubidoux, M. A., Chang, A. E., Kleer, C. G., Diehl, K. M., Cimmino, V. M., Pierce, L., Hayes, D., et al. (2006) · Cancer · doi:10.1002/cncr.22266 · Cited by 290
Metadata
- Authors
- Sickles, E. A., Wolverton, D. E., & Dee, K. E.
- Venue
- Radiology
- Published
- 2002-09
- Volume
- 224
- Issue
- 3
- Pages
- 861-869
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2013755458
- Cited by
- 249
- References
- 0
- FWCI
- 11.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance Parameters for Screening and Diagnostic Mammography: Specialist and General Radiologists. https://app.cochat.ai/papers/10.1148/radiol.2243011482
- The paper
- Sickles, E. A., Wolverton, D. E., & Dee, K. E. (2002). Performance Parameters for Screening and Diagnostic Mammography: Specialist and General Radiologists. Radiology. https://doi.org/10.1148/radiol.2243011482
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.