Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 314

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Comparison of Screening Mammography in the United States and the United Kingdom

Smith-Bindman, Rebecca·2003·JAMA

Abstract

CONTEXT: Screening mammography differs between the United States and the United Kingdom; a direct comparison may suggest methods to improve the practice. OBJECTIVE: To compare screening mammography performance between the United States and the United Kingdom among similar-aged women. DESIGN, SETTING, AND PARTICIPANTS: Women aged 50 years or older were identified who underwent 5.5 million mammograms from January 1, 1996, to December 31, 1999, within 3 large-scale mammography registries or screening programs: the Breast Cancer Surveillance Consortium (BCSC, n = 978 591) and National Breast and Cervical Cancer Early Detection Program (NBCCEDP, n = 613 388) in the United States; and the National Health Service Breast Screening Program (NHSBSP, n = 3.94 million) in the United Kingdom. A total of 27 612 women were diagnosed with breast cancer (invasive or ductal carcinoma in situ) within 12 months of screening among the 3 groups. MAIN OUTCOME MEASURES: Recall rates (recommendation for further evaluation including diagnostic imaging, ultrasound, clinical examination, or biopsy) and cancer detection rates were calculated for first and subsequent mammograms, and within 5-year age groups. RESULTS: Recall rates were approximately twice as high in the United States than in the United Kingdom for all age groups; however, cancer rates were similar. Among women aged 50 to 54 years who underwent a first screening mammogram, 14.4% in the BCSC and 12.5% in the NBCCEDP were recalled for further evaluation vs only 7.6% in the NHSBSP. Cancer detection rates per 1000 mammogram screens were 5.8, 5.9, and 6.3, in the BCSC, NBCCEDP, and NHSBSP, respectively. Recall rates were lower for subsequent examinations in all 3 settings but remained twice as high in the United States. A similar percentage of women underwent biopsy in each setting, but rates of percutaneous biopsy were lower and open surgical biopsy higher in the United States. Open surgical biopsies not resulting in a diagnosis of cancer (negative biopsies) were twice as high in the United States than in the United Kingdom. Based on a 10-year period of screening 1000 women aged 50 to 59 years, 477, 433, and 175 women in the BCSC, NBCCEDP, and NHSBSP, respectively, would be recalled; and for women aged 60 to 69 years, 396, 334, and 133 women, respectively. The estimated cancer detection rates per 1000 women aged 50 to 59 years were 24.5, 23.8, and 19.4, respectively, and for women aged 60 to 69 years, 31.5, 26.6, and 27.9, respectively. CONCLUSIONS: Recall and negative open surgical biopsy rates are twice as high in US settings than in the United Kingdom but cancer detection rates are similar. Efforts to improve US mammographic screening should target lowering the recall rate without reducing the cancer detection rate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.290.16.2129

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

See all 314

Metadata

Authors
Smith-Bindman, R.
Venue
JAMA
Published
2003-10-22
Volume
290
Issue
16
Pages
2129
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2146899794
Cited by
314
References
27
FWCI
10.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Screening Mammography in the United States and the United Kingdom. https://app.cochat.ai/papers/10.1001/jama.290.16.2129
The paper
Smith-Bindman, R. (2003). Comparison of Screening Mammography in the United States and the United Kingdom. JAMA. https://doi.org/10.1001/jama.290.16.2129

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.