PET Diagnostic Accuracy: Improvement with In-Line PET-CT System: Initial Results
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
The authors describe the initial application for tumor staging with an in-line system with a positron emission tomographic (PET) scanner and a multi-detector row helical computed tomographic (CT) scanner combined in one machine. Fifty-three patients underwent imaging with four CT tube currents and PET emission and transmission data acquisition. Stepwise analysis of coregistered images revealed a significant (P <.05, McNemar test) improvement in lesion classification between PET images alone and coregistered images from the PET-CT examination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946
Pitfalls in Oncologic Diagnosis with FDG PET Imaging: Physiologic and Benign Variants
Shreve, P. D., Anzai, Y., & Wahl, R. L. (1999) · RadioGraphics · doi:10.1148/radiographics.19.1.g99ja0761 · Cited by 827
Strauss, L. G. (1996) · European Journal of Nuclear Medicine · doi:10.1007/bf01367602 · Cited by 527
Wahl, R. L., Quint, L. E., Greenough, R. L., Meyer, C. R., White, R. I., & Orringer, M. B. (1994) · Radiology · doi:10.1148/radiology.191.2.8153308 · Cited by 430
Imaging of lymphoma with PET with 2-[F-18]-fluoro-2-deoxy-D-glucose: correlation with CT.
Newman, J. S., Francis, I. R., Kaminski, M. S., & Wahl, R. L. (1994) · Radiology · doi:10.1148/radiology.190.1.8259386 · Cited by 265
Stumpe, K. D. M., Urbinelli, M., Steinert, H. C., Glanzmann, C., Buck, A., & von Schulthess, G. K. (1998) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050275 · Cited by 261
Self-citationWhole-body PET: physiological and artifactual fluorodeoxyglucose accumulations.
Engel, H., Steinert, H. C., Buck, A., Berthold, T., Böni, R. A. H., & von Schulthess, G. K. (1996) · PubMed · Cited by 259
Self-citationDetection of extrathoracic metastases by positron emission tomography in lung cancer
Weder, W., Schmid, R. A., Bruchhaus, H., Hillinger, S., von Schulthess, G. K., & Steinert, H. C. (1998) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(98)00675-4 · Cited by 231
Self-citationCombined PET/CT Imaging in Oncology Impact on Patient Management
Kluetz, P. (2000) · Clinical Positron Imaging · doi:10.1016/s1095-0397(01)00055-3 · Cited by 226
Wahl, R. L., Quint, L. E., Cieslak, R., Aisen, A. M., Koeppe, R. A., & Meyer, C. R. (1993) · PubMed · Cited by 219
Cited by
Lardinois, D., Weder, W., Hany, T. F., Kamel, E. M., Korom, S., Seifert, B., von Schulthess, G. K., & Steinert, H. C. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022136 · Cited by 1,416
Self-citationNoninvasive Staging of Non-small Cell Lung Cancer*
Toloza, E. M., Harpole, L., & McCrory, D. C. (2003) · Chest · doi:10.1378/chest.123.1_suppl.137s · Cited by 745
Noninvasive Staging of Non-small Cell Lung Cancer
Silvestri, G. A., Gould, M. K., Margolis, M. L., Tanoue, L. T., McCrory, D., Toloza, E., & Detterbeck, F. (2007) · Chest · doi:10.1378/chest.07-1360 · Cited by 622
Integrated PET/CT: Current Applications and Future Directions
von Schulthess, G. K., Steinert, H. C., & Hany, T. F. (2006) · Radiology · doi:10.1148/radiol.2382041977 · Cited by 619
Self-citationWhole-Body Dual-Modality PET/CT and Whole-Body MRI for Tumor Staging in Oncology
Antoch, G. (2003) · JAMA · doi:10.1001/jama.290.24.3199 · Cited by 551
Antoch, G., Saoudi, N., Kuehl, H., Dahmen, G., Mueller, S. P., Beyer, T., Bockisch, A., Debatin, J. F., & Freudenberg, L. S. (2004) · Journal of Clinical Oncology · doi:10.1200/jco.2004.08.120 · Cited by 435
Blodgett, T. M., Meltzer, C. C., & Townsend, D. W. (2007) · Radiology · doi:10.1148/radiol.2422051113 · Cited by 387
Selzner, M., Hany, T. F., Wildbrett, P., McCormack, L., Kadry, Z., & Clavien, P.-A. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000146145.69835.c5 · Cited by 348
Self-citationSironi, S., Buda, A., Picchio, M., Perego, P., Moreni, R., Pellegrino, A., Colombo, M., Mangioni, C., Messa, C., & Fazio, F. (2006) · Radiology · doi:10.1148/radiol.2381041799 · Cited by 315
Petrowsky, H., Wildbrett, P., Husarik, D. B., Hany, T. F., Tam, S., Jochum, W., & Clavien, P.-A. (2006) · Journal of Hepatology · doi:10.1016/j.jhep.2006.03.009 · Cited by 305
Self-citationBoland, G. W. L., Dwamena, B. A., Jagtiani Sangwaiya, M., Goehler, A. G., Blake, M. A., Hahn, P. F., Scott, J. A., & Kalra, M. K. (2011) · Radiology · doi:10.1148/radiol.11100569 · Cited by 282
Pitfalls and artifacts in 18FDG PET and PET/CT oncologic imaging
Cook, G. J. R., Wegner, E. A., & Fogelman, I. (2004) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2003.12.003 · Cited by 258
Chagpar, A. B., Middleton, L. P., Sahin, A. A., Dempsey, P., Buzdar, A. U., Mirza, A. N., Ames, F. C., Babiera, G. V., Feig, B. W., Hunt, K. K., et al. (2006) · Annals of Surgery · doi:10.1097/01.sla.0000197714.14318.6f · Cited by 245
Overview of the clinical effectiveness of positron emission tomography imaging in selected cancers
Facey, K., Bradbury, I., Laking, G., & Payne, E. (2007) · Health Technology Assessment · doi:10.3310/hta11440 · Cited by 219
Screening for bone metastases: whole-body MRI using a 32-channel system versus dual-modality PET-CT
Schmidt, G. P., Schoenberg, S. O., Schmid, R., Stahl, R., Tiling, R., Becker, C. R., Reiser, M. F., & Baur-Melnyk, A. (2007) · European Radiology · doi:10.1007/s00330-006-0361-8 · Cited by 209
“Different authors report a significant decrease of ambiguous lesions and an improvement of specificity for PET-CT compared with PET alone for the detection malignant disease [6, 30–32].”
Computed Tomography: Revolutionizing the Practice of Medicine for 40 Years
Rubin, G. D. (2014) · Radiology · doi:10.1148/radiol.14141356 · Cited by 197
De Wever, W., Ceyssens, S., Mortelmans, L., Stroobants, S., Marchal, G., Bogaert, J., & Verschakelen, J. A. (2007) · European Radiology · doi:10.1007/s00330-006-0284-4 · Cited by 188
“The initial reports in the literature also suggest that integrated PET-CT is superior in accuracy of Nstaging in comparison with PET alone, with CT alone, and with visually correlation of PET and CT images arranged side by side [3, 10, 12, 20, 22, 23].”
BackgroundResultInfluentialUnknown Primary Tumors: Detection with Dual-Modality PET/CT—Initial Experience
Gutzeit, A., Antoch, G., Kühl, H., Egelhof, T., Fischer, M., Hauth, E., Goehde, S., Bockisch, A., Debatin, J., & Freudenberg, L. (2005) · Radiology · doi:10.1148/radiol.2341031554 · Cited by 175
Cohade, C., & Wahl, R. L. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127312 · Cited by 168
(2004) · PubMed · Cited by 141
Aschoff, P., Plathow, C., Beyer, T., Lichy, M. P., Erb, G., Öksüz, M. Ö., Claussen, C. D., & Pfannenberg, C. (2012) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1919-5 · Cited by 29
Metadata
- Authors
- Hany, T. F., Steinert, H. C., Goerres, G. W., Buck, A., & von Schulthess, G. K.
- Venue
- Radiology
- Published
- 2002-11
- Volume
- 225
- Issue
- 2
- Pages
- 575-581
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2153173584
- Cited by
- 323
- References
- 15
- FWCI
- 24.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.