Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 175

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Unknown Primary Tumors: Detection with Dual-Modality PET/CT—Initial Experience

Gutzeit, Andreas, Antoch, Gerald, Kühl, Hilmar, Egelhof, Thomas, Fischer, Markus, Hauth, Elke, Goehde, Susanne, Bockisch, Andreas, Debatin, Jörg, Freudenberg, Lutz · 2005 · Radiology

Abstract

PURPOSE: To retrospectively evaluate fused positron emission tomography (PET)/computed tomography (CT) in depicting the primary lesion in cancer of an unknown primary tumor, compared with PET, CT, and PET and CT side-by-side evaluation. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. Forty-five patients (26 men and 19 women) with metastatic cervical adenopathy (n = 18) or extracervical metastases (n = 27) of unknown primary tumor were included. The mean age of the patients was 57 years (range, 29-95 years). PET/CT imaging was performed in all patients 1 hour after administration of 350 MBq of fluorodeoxyglucose with a whole-body field of view. Contrast agents were administered orally and intravenously in all patients to ensure diagnostic CT data. PET/CT data sets were evaluated for the primary tumor, and imaging results were compared with those of CT, PET, and PET and CT side-by-side evaluation. Differences in diagnostic performance were assessed by using the McNemar test with Bonferroni correction, which accounts for multiple comparisons. RESULTS: PET/CT depicted the primary tumor in 15 (33%) of 45 patients. In 30 (67%) patients, the primary tumor site remained occult (P > .05). PET and CT side-by-side evaluation depicted 13 (29%) of 45 tumors (P > .05). PET alone revealed the primary tumor in 11 (24%) of 45 patients (P > .05), while CT alone helped in the correct diagnosis in eight (18%) of 45 patients (P > .05). There were no significant differences between the diagnostic accuracies of PET/CT and the other imaging modalities. CONCLUSION: PET/CT was able to depict more primary tumors, though not significantly, than either of the other imaging modalities, but larger patient cohorts are required to finally judge its value for revealing the primary tumor site.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2341031554

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 175

Metadata

Authors
Gutzeit, A., Antoch, G., Kühl, H., Egelhof, T., Fischer, M., Hauth, E., Goehde, S., Bockisch, A., Debatin, J., & Freudenberg, L.
Venue
Radiology
Published
2005-01
Volume
234
Issue
1
Pages
227-234
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2151673012
Cited by
175
References
2
FWCI
9.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Unknown Primary Tumors: Detection with Dual-Modality PET/CT—Initial Experience. https://app.cochat.ai/papers/10.1148/radiol.2341031554
The paper
Gutzeit, A., Antoch, G., Kühl, H., Egelhof, T., Fischer, M., Hauth, E., Goehde, S., Bockisch, A., Debatin, J., & Freudenberg, L. (2005). Unknown Primary Tumors: Detection with Dual-Modality PET/CT—Initial Experience. Radiology. https://doi.org/10.1148/radiol.2341031554

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.