The DOI matches its Crossref record.
Lung Cancers Missed at Low-Dose Helical CT Screening in a General Population: Comparison of Clinical, Histopathologic, and Imaging Findings
Abstract
PURPOSE: To compare clinical, histopathologic, and imaging features of lung cancers missed at low-radiation-dose helical computed tomography (CT). MATERIALS AND METHODS: Eighty-three primary lung cancers were found during an annual low-dose CT screening program and confirmed histopathologically at either surgery or biopsy. Thirty-two of these lung cancers were missed on 39 CT scans: on 23 scans owing to detection errors and on 16 owing to interpretation errors. The clinical characteristics, CT features, and histopathologic findings of these missed lung cancers were correlated. RESULTS: All missed cancers were intrapulmonary, and 28 (88%) were stage IA. All 20 detection errors occurred in cases of adenocarcinoma, 17 (85%) of which were well-differentiated tumors and 11 (55%) of which were in nonsmoking women. The mean size of cancers missed owing to detection error, 9.8 mm, was smaller than that of cancers missed owing to interpretation error, 15.9 mm (P <.001). In the detection error group, the percentages of nodules with ground-glass opacity (91%) or judged to be subtle (91%) were greater than those of nodules in the interpretation error group (38% and 25%, respectively) (P <.001). In the detection error group, 83% (19/23) of cancers were overlapped with, obscured by, or similar in appearance to normal structures such as pulmonary vessels. On 14 of the 16 CT scans with which there were interpretation errors, the CT findings mimicked benign disease, and the patients also had underlying lung disease, such as tuberculosis, emphysema, or lung fibrosis. CONCLUSION: The lung cancers missed at low-dose CT screening in this series generally were very subtle and appeared as small faint nodules, overlapping normal structures, or opacities in a complex background of other disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Computer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855
Self-citationBreast Cancer, Version 4.2017, NCCN Clinical Practice Guidelines in Oncology
Gradishar, W. J., Anderson, B. O., Balassanian, R., Blair, S. L., Burstein, H. J., Cyr, A., Elias, A. D., Farrar, W. B., Forero, A., Giordano, S. H., et al. (2018) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2018.0012 · Cited by 1,609
Techniques and Applications of Automatic Tube Current Modulation for CT
Kalra, M. K., Maher, M. M., Toth, T. L., Schmidt, B., Westerman, B. L., Morgan, H. T., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2333031150 · Cited by 725
Lung Cancer Screening, Version 3.2018, NCCN Clinical Practice Guidelines in Oncology
Wood, D. E., Kazerooni, E. A., Baum, S. L., Eapen, G. A., Ettinger, D. S., Hou, L., Jackman, D. M., Klippenstein, D., Kumar, R., Lackner, R. P., et al. (2018) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2018.0020 · Cited by 611
Current status and future potential of computer-aided diagnosis in medical imaging
Doi, K. (2005) · The British Journal of Radiology · doi:10.1259/bjr/82933343 · Cited by 444
Self-citation
Metadata
- Authors
- Li, F., Sone, S., Abe, H., MacMahon, H., Armato, S. G., & Doi, K.
- Venue
- Radiology
- Published
- 2002-12
- Volume
- 225
- Issue
- 3
- Pages
- 673-683
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2002774010
- Cited by
- 201
- References
- 0
- FWCI
- 10.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lung Cancers Missed at Low-Dose Helical CT Screening in a General Population: Comparison of Clinical, Histopathologic, and Imaging Findings. https://app.cochat.ai/papers/10.1148/radiol.2253011375
- The paper
- Li, F., Sone, S., Abe, H., MacMahon, H., Armato, S. G., & Doi, K. (2002). Lung Cancers Missed at Low-Dose Helical CT Screening in a General Population: Comparison of Clinical, Histopathologic, and Imaging Findings. Radiology. https://doi.org/10.1148/radiol.2253011375
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.