The DOI matches its Crossref record.
Aortoiliac and Renal Arteries: Prospective Intraindividual Comparison of Contrast-enhanced Three-dimensional MR Angiography and Multi–Detector Row CT Angiography
Open accessAbstract
PURPOSE: To compare contrast material-enhanced three-dimensional (3D) magnetic resonance (MR) angiography and multi-detector row computed tomographic (CT) angiography in the same patients for assessment of the aortoiliac and renal arteries, with digital subtraction angiography (DSA) as the standard of reference. MATERIALS AND METHODS: DSA, 3D MR angiography, and multi-detector row CT angiography were performed in 46 consecutive patients. A total of 769 arterial segments were analyzed for arterial stenosis by using a four-point grading system. Aneurysmal changes were noted. The time required for performing 3D reconstructions and image analysis of both MR and CT data sets was measured. Patient acceptance for each modality was assessed with a visual analogue scale. Statistical analysis of data was performed. RESULTS: Sensitivity of MR angiography for detection of hemodynamically significant arterial stenosis was 92% for reader 1 and 93% for reader 2, and specificity was 100% and 99%, respectively. Sensitivity of CT angiography was 91% for reader 1 and 92% for reader 2, and specificity was 99% and 99%, respectively. Differences between the two modalities were not significant. Interobserver and intermodality agreement was excellent (kappa = 0.88-0.90). The time for performance of 3D reconstruction and image analysis of CT data sets was significantly longer than that for MR data sets (P <.001). Patient acceptance was best for CT angiography (P =.016). CONCLUSION: There is no statistically significant difference between 3D MR angiography and multi-detector row CT angiography in the detection of hemodynamically significant arterial stenosis of the aortoiliac and renal arteries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hirsch, A. T., Haskal, Z. J., Hertzer, N. R., Bakal, C. W., Creager, M. A., Halperin, J. L., Hiratzka, L. F., Murphy, W. R. C., Olin, J. W., Puschett, J. B., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.174526 · Cited by 3,708
Schnorr, J., Wagner, S., Abramjuk, C., Wojner, I., Schink, T., Kroencke, T. J., Schellenberger, E., Hamm, B., Pilgrimm, H., & Taupitz, M. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000133944.30119.cc · Cited by 54
Metadata
- Authors
- Willmann, J. K., Wildermuth, S., Pfammatter, T., Roos, J. E., Seifert, B., Hilfiker, P. R., Marincek, B., & Weishaupt, D.
- Venue
- Radiology
- Published
- 2003-03
- Volume
- 226
- Issue
- 3
- Pages
- 798-811
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2141327062
- Cited by
- 197
- References
- 0
- FWCI
- 22.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Aortoiliac and Renal Arteries: Prospective Intraindividual Comparison of Contrast-enhanced Three-dimensional MR Angiography and Multi–Detector Row CT Angiography. https://app.cochat.ai/papers/10.1148/radiol.2271020014
- The paper
- Willmann, J. K., Wildermuth, S., Pfammatter, T., Roos, J. E., Seifert, B., Hilfiker, P. R., Marincek, B., & Weishaupt, D. (2003). Aortoiliac and Renal Arteries: Prospective Intraindividual Comparison of Contrast-enhanced Three-dimensional MR Angiography and Multi–Detector Row CT Angiography. Radiology. https://doi.org/10.1148/radiol.2271020014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.