The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Detection of Active Colonic Hemorrhage with Use of Helical CT: Findings in a Swine Model
Abstract
PURPOSE: To evaluate the feasibility of helical computed tomography (CT) as an imaging modality for depicting active colonic hemorrhage in a swine model. MATERIALS AND METHODS: Controlled extravasation of contrast material-enhanced blood (CEB) from 140 to 180 HU and at varying rates (0.3-1.0 mL/min) was performed during a 30-second period by using a microcatheter system placed within the descending colon of 14 swine. CEB was immediately followed by extravasation of unopacified blood at the same location and rate during serial helical CT imaging of the extravasation site. Region-of-interest analysis allowed quantification of the dilution of extravasated CEB as a function of time that was then modeled mathematically based on iodine mass and volume balances. Nonlinear least squares analysis was performed to optimize fitting of the model to experimental data, with a maximum regression value (R2) of 1.0 indicating a perfect fit. This model enabled the computer simulation of CT imaging of multiple combinations of bleeding rates and CEB attenuation to determine the sensitivity of helical CT for depicting active colonic bleeding. RESULTS: Sixteen swine examinations yielded 16 CEB dilution curves. An excellent fit of the model to each dilution curve was achieved, as indicated by a mean R2 value of 0.8402. Swine examinations alone showed that targeted CT could depict CEB as low as 111 HU extravasating at a rate of 0.3 mL/min. Simulations that were based on helical CT images with 5-mm collimation reconstructed every 3 mm and that used the model indicated bleeding rates below 0.4 mL/min are detectable, provided peak aortic enhancement reaches 100 HU. CONCLUSION: Conservatively, helical CT has the potential to depict active colonic hemorrhage at rates of 0.5 mL/min or less.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
Cited by
Yoon, W., Jeong, Y. Y., Shin, S. S., Lim, H. S., Song, S. G., Jang, N. G., Kim, J. K., & Kang, H. K. (2006) · Radiology · doi:10.1148/radiol.2383050175 · Cited by 295
Metadata
- Authors
- Kuhle, W. G., & Sheiman, R. G.
- Venue
- Radiology
- Published
- 2003-09
- Volume
- 228
- Issue
- 3
- Pages
- 743-752
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2163936917
- Cited by
- 242
- References
- 1
- FWCI
- 5.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Active Colonic Hemorrhage with Use of Helical CT: Findings in a Swine Model. https://app.cochat.ai/papers/10.1148/radiol.2283020756
- The paper
- Kuhle, W. G., & Sheiman, R. G. (2003). Detection of Active Colonic Hemorrhage with Use of Helical CT: Findings in a Swine Model. Radiology. https://doi.org/10.1148/radiol.2283020756
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.