Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 295

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Acute Massive Gastrointestinal Bleeding: Detection and Localization with Arterial Phase Multi–Detector Row Helical CT

Yoon, Woong, Jeong, Yong Yeon, Shin, Sang Soo, Lim, Hyo Soon, Song, Sang Gook, Jang, Nam Gyu, Kim, Jae Kyu, Kang, Heoung Keun·2006·Radiology

Abstract

PURPOSE: To prospectively evaluate accuracy of arterial phase multi-detector row helical computed tomography (CT) for detection and localization of acute massive gastrointestinal (GI) bleeding, with angiography as reference standard. MATERIALS AND METHODS: Institutional review board approved this study; written informed consent was obtained from each patient or patient's family after procedures, including radiation dose, were explained. Twenty-six consecutive patients (17 men, nine women; age range, 18-89 years) had acute massive GI bleeding (defined as requirement of transfusion of at least 4 units of blood during 24 hours in the hospital or as hypotension with systolic blood pressure <90 mm Hg) and underwent arterial phase multi-detector row CT before angiography. Scans were obtained during arterial phase to identify extravasation of contrast material with attenuation greater than 90 HU within bowel lumen; this finding was considered diagnostic for active GI bleeding. Presence of contrast medium extravasation in each anatomic location was recorded. Sensitivity, specificity, positive and negative predictive values, and accuracy of multi-detector row CT for detection of acute GI bleeding were assessed. Accuracy for localization of acute GI bleeding was assessed by comparing locations of active bleeding at both multi-detector row CT and angiography in each patient who had active bleeding. RESULTS: Arterial phase multi-detector row CT depicted extravasation of contrast material in 21 of 26 patients. Overall location-based sensitivity, specificity, accuracy, and positive and negative predictive values of multi-detector row CT for detection of GI bleeding were 90.9% (20 of 22), 99% (107 of 108), 97.6% (127 of 130), 95% (20 of 21), and 98% (107 of 109), respectively. Overall patient-based accuracy of multi-detector row CT for detection of acute GI bleeding was 88.5% (23 of 26). The location of contrast material extravasation on multi-detector row CT scans corresponded exactly to that of active bleeding on angiograms in all patients with contrast medium extravasation at both multi-detector row CT and angiography. CONCLUSION: Arterial phase multi-detector row CT is accurate for detection and localization of bleeding sites in patients with acute massive GI bleeding.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2383050175

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 295

Metadata

Authors
Yoon, W., Jeong, Y. Y., Shin, S. S., Lim, H. S., Song, S. G., Jang, N. G., Kim, J. K., & Kang, H. K.
Venue
Radiology
Published
2006-04
Volume
239
Issue
1
Pages
160-167
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2143776976
Cited by
295
References
7
FWCI
16.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Acute Massive Gastrointestinal Bleeding: Detection and Localization with Arterial Phase Multi–Detector Row Helical CT. https://app.cochat.ai/papers/10.1148/radiol.2383050175
The paper
Yoon, W., Jeong, Y. Y., Shin, S. S., Lim, H. S., Song, S. G., Jang, N. G., Kim, J. K., & Kang, H. K. (2006). Acute Massive Gastrointestinal Bleeding: Detection and Localization with Arterial Phase Multi–Detector Row Helical CT. Radiology. https://doi.org/10.1148/radiol.2383050175

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.