Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 283

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Pancreatic Malignancy: Value of Arterial, Pancreatic, and Hepatic Phase Imaging with Multi–Detector Row CT

Fletcher, Joel G., Wiersema, Maurits J., Farrell, Michael A., Fidler, Jeff L., Burgart, Lawrence J., Koyama, Takashi, Johnson, C. Daniel, Stephens, David H., Ward, Ellen M., Harmsen, W. Scott·2003·Radiology

Abstract

PURPOSE: To assess the value of arterial, pancreatic, and hepatic phase imaging at multi-detector row computed tomography (CT) of the pancreas for pancreatic malignancy. MATERIALS AND METHODS: Thirty-nine patients suspected of having resectable pancreatic adenocarcinoma underwent triple-phase multi-detector row CT. Images obtained during each phase were interpreted by one radiologist who evaluated presence of tumor, vascular invasion, and flow artifacts in the superior mesenteric vein and measured attenuation of tumor, normal pancreas, aorta, and superior mesenteric vein. Results were compared with histologic, follow-up, and correlative imaging findings. RESULTS: Mean tumor-to-gland attenuation difference was greatest on images obtained in the pancreatic phase (42 HU) versus that on those obtained in the hepatic phase (35 HU) and in the arterial phase (25 HU). For tumor detection, sensitivity of the images obtained in pancreatic (0.97 [29 of 30]) and hepatic (0.93 [28 of 30]) phases was superior to that of those obtained in arterial phase (0.63 [19 of 30]) (P < or =.008). For vascular invasion detection, sensitivity of images obtained in the hepatic phase (0.83) was better than that of those obtained in the pancreatic (0.58) and arterial (0.25) phases. Images obtained in the pancreatic phase demonstrated more flow artifacts and decreased attenuation in the superior mesenteric vein, compared with the artifacts revealed on images obtained in the hepatic phase. CONCLUSION: Routine acquisition of images in the arterial phase is unnecessary for detection of pancreatic adenocarcinoma. Images of the pancreas obtained in the hepatic phase with multi-detector row CT most accurately display vascular invasion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2291020582

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 283

Metadata

Authors
Fletcher, J. G., Wiersema, M. J., Farrell, M. A., Fidler, J. L., Burgart, L. J., Koyama, T., Johnson, C. D., Stephens, D. H., Ward, E. M., & Harmsen, W. S.
Venue
Radiology
Published
2003-10
Volume
229
Issue
1
Pages
81-90
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2125267022
Cited by
283
References
15
FWCI
4.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pancreatic Malignancy: Value of Arterial, Pancreatic, and Hepatic Phase Imaging with Multi–Detector Row CT. https://app.cochat.ai/papers/10.1148/radiol.2291020582
The paper
Fletcher, J. G., Wiersema, M. J., Farrell, M. A., Fidler, J. L., Burgart, L. J., Koyama, T., Johnson, C. D., Stephens, D. H., Ward, E. M., & Harmsen, W. S. (2003). Pancreatic Malignancy: Value of Arterial, Pancreatic, and Hepatic Phase Imaging with Multi–Detector Row CT. Radiology. https://doi.org/10.1148/radiol.2291020582

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.