The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Hepatic Flow Parameters Measured with MR Imaging and Doppler US: Correlations with Degree of Cirrhosis and Portal Hypertension
Abstract
PURPOSE: To determine the correlations between hemodynamic parameters of hepatic flow measured with magnetic resonance (MR) imaging and Doppler ultrasonography (US) and the severity of cirrhosis and portal hypertension. MATERIALS AND METHODS: Forty-six patients referred for measurements of portal venous pressure (three with normal liver, 12 with chronic hepatitis, and 31 with cirrhosis [10 with Child-Pugh class A cirrhosis; 13 with class B cirrhosis; and eight with class C cirrhosis]) were included in the study. Apparent liver perfusion, apparent arterial and portal perfusion, portal fraction, distribution volume, and mean transit time were measured with dynamic contrast material-enhanced MR imaging. Portal velocity, portal flow, congestion index, right hepatic artery resistance index, and modified hepatic index were measured with Doppler US. Results in patients with cirrhosis and those without cirrhosis were compared with the Wilcoxon rank sum test. Correlations were assessed with Spearman rank correlation coefficients. RESULTS: With MR imaging, all flow parameters except distribution volume were significantly different between patients with and those without cirrhosis (P <.05). There was a significant correlation between all flow parameters measured with MR imaging and portal pressure (P <.02). Apparent arterial (P =.024) and portal (P <.001) perfusion, portal fraction (P <.001), and mean transit time (P =.004) were correlated with Child-Pugh class. Flow parameters measured with Doppler US did not differ significantly between patients with and those without cirrhosis. Only right hepatic arterial resistance (P <.007) and portal flow (P <.043) were weakly (r < 0.7) correlated with portal pressure. No Doppler US parameter was correlated with Child-Pugh class. CONCLUSION: Hepatic flow parameters measured with MR imaging correlate with the severity of cirrhosis and portal hypertension. Doppler US parameters are only weakly correlated with portal pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transection of the oesophagus for bleeding oesophageal varices
Pugh, R. N. H., Murray-Lyon, I. M., Dawson, J. L., Pietroni, M. C., & Williams, R. (1973) · Journal of British Surgery · doi:10.1002/bjs.1800600817 · Cited by 7,941
Feu, F., García-Pagán, J. C., Bosch, J., Luca, A., Escorsell, A., Rodés, J., & Terés, J. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91740-3 · Cited by 591
Complications of cirrhosis. I. Portal hypertension
Bosch, J., & García-Pagán, J. C. (2000) · Journal of Hepatology · doi:10.1016/s0168-8278(00)80422-5 · Cited by 490
Lautt, W. W. (1985) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.1985.249.5.g549 · Cited by 487
Van Beers, B. E., Leconte, I., Materne, R., Smith, A. M., Jamart, J., & Horsmans, Y. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.3.1760667 · Cited by 321
Self-citationAssessment of hepatic perfusion parameters with dynamic MRI
Materne, R., Smith, A. M., Peeters, F., Dehoux, J. P., Keyeux, A., Horsmans, Y., & Van Beers, B. E. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10045 · Cited by 226
Self-citationOrrego, H., Blendis, L. M., Crossley, I. R., MeDline, A., Macdonald, A., Ritchie, S., & Israel, Y. (1981) · Gastroenterology · doi:10.1016/0016-5085(81)90018-4 · Cited by 199
Alcoholic liver injury: Defenestration in noncirrhotic livers—a scanning electron microscopic study
Horn, T., Christoffersen, P., & Henriksen, J. H. (1987) · Hepatology · doi:10.1002/hep.1840070117 · Cited by 182
Sacerdoti, D., Merkel, C., Bolognesi, M., Amodio, P., Angeli, P., & Gatta, A. (1995) · Gastroenterology · doi:10.1016/0016-5085(95)90214-7 · Cited by 146
Materne, R., BEERS, B. E. V., Smith, A. M., Leconte, I., Jamart, J., Dehoux, J., Keyeux, A., & Horsmans, Y. (2000) · Clinical Science · doi:10.1042/cs0990517 · Cited by 139
Self-citation
Cited by
Diffusion-weighted MR Imaging of the Liver
Taouli, B., & Koh, D.-M. (2010) · Radiology · doi:10.1148/radiol.09090021 · Cited by 810
Patel, J., Sigmund, E. E., Rusinek, H., Oei, M., Babb, J. S., & Taouli, B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22081 · Cited by 371
Huwart, L., Sempoux, C., Salameh, N., Jamart, J., Annet, L., Sinkus, R., Peeters, F., ter Beek, L. C., Horsmans, Y., & Van Beers, B. E. (2007) · Radiology · doi:10.1148/radiol.2452061673 · Cited by 365
Self-citationThe management of portal hypertension: Rational basis, available treatments and future options
Bosch, J., Berzigotti, A., Garcia-Pagan, J. C., & Abraldes, J. G. (2008) · Journal of Hepatology · doi:10.1016/j.jhep.2008.01.021 · Cited by 319
Perfusion Imaging of the Liver: Current Challenges and Future Goals
Pandharipande, P. V., Krinsky, G. A., Rusinek, H., & Lee, V. S. (2005) · Radiology · doi:10.1148/radiol.2343031362 · Cited by 294
Metadata
- Authors
- Annet, L., Materne, R., Danse, E., Jamart, J., Horsmans, Y., & Van Beers, B. E.
- Venue
- Radiology
- Published
- 2003-11
- Volume
- 229
- Issue
- 2
- Pages
- 409-414
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2062431608
- Cited by
- 295
- References
- 17
- FWCI
- 4.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hepatic Flow Parameters Measured with MR Imaging and Doppler US: Correlations with Degree of Cirrhosis and Portal Hypertension. https://app.cochat.ai/papers/10.1148/radiol.2292021128
- The paper
- Annet, L., Materne, R., Danse, E., Jamart, J., Horsmans, Y., & Van Beers, B. E. (2003). Hepatic Flow Parameters Measured with MR Imaging and Doppler US: Correlations with Degree of Cirrhosis and Portal Hypertension. Radiology. https://doi.org/10.1148/radiol.2292021128
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.