Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 295

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Hepatic Flow Parameters Measured with MR Imaging and Doppler US: Correlations with Degree of Cirrhosis and Portal Hypertension

Annet, Laurence, Materne, Roland, Danse, Etienne, Jamart, Jacques, Horsmans, Yves, Van Beers, Bernard E.·2003·Radiology

Abstract

PURPOSE: To determine the correlations between hemodynamic parameters of hepatic flow measured with magnetic resonance (MR) imaging and Doppler ultrasonography (US) and the severity of cirrhosis and portal hypertension. MATERIALS AND METHODS: Forty-six patients referred for measurements of portal venous pressure (three with normal liver, 12 with chronic hepatitis, and 31 with cirrhosis [10 with Child-Pugh class A cirrhosis; 13 with class B cirrhosis; and eight with class C cirrhosis]) were included in the study. Apparent liver perfusion, apparent arterial and portal perfusion, portal fraction, distribution volume, and mean transit time were measured with dynamic contrast material-enhanced MR imaging. Portal velocity, portal flow, congestion index, right hepatic artery resistance index, and modified hepatic index were measured with Doppler US. Results in patients with cirrhosis and those without cirrhosis were compared with the Wilcoxon rank sum test. Correlations were assessed with Spearman rank correlation coefficients. RESULTS: With MR imaging, all flow parameters except distribution volume were significantly different between patients with and those without cirrhosis (P <.05). There was a significant correlation between all flow parameters measured with MR imaging and portal pressure (P <.02). Apparent arterial (P =.024) and portal (P <.001) perfusion, portal fraction (P <.001), and mean transit time (P =.004) were correlated with Child-Pugh class. Flow parameters measured with Doppler US did not differ significantly between patients with and those without cirrhosis. Only right hepatic arterial resistance (P <.007) and portal flow (P <.043) were weakly (r < 0.7) correlated with portal pressure. No Doppler US parameter was correlated with Child-Pugh class. CONCLUSION: Hepatic flow parameters measured with MR imaging correlate with the severity of cirrhosis and portal hypertension. Doppler US parameters are only weakly correlated with portal pressure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2292021128

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 295

Metadata

Authors
Annet, L., Materne, R., Danse, E., Jamart, J., Horsmans, Y., & Van Beers, B. E.
Venue
Radiology
Published
2003-11
Volume
229
Issue
2
Pages
409-414
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2062431608
Cited by
295
References
17
FWCI
4.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hepatic Flow Parameters Measured with MR Imaging and Doppler US: Correlations with Degree of Cirrhosis and Portal Hypertension. https://app.cochat.ai/papers/10.1148/radiol.2292021128
The paper
Annet, L., Materne, R., Danse, E., Jamart, J., Horsmans, Y., & Van Beers, B. E. (2003). Hepatic Flow Parameters Measured with MR Imaging and Doppler US: Correlations with Degree of Cirrhosis and Portal Hypertension. Radiology. https://doi.org/10.1148/radiol.2292021128

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.