Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 228

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

MR Quantification of Hepatic Iron Concentration

Alústiza, José M., Artetxe, José, Castiella, Agustín, Agirre, Cristina, Emparanza, José I., Otazua, Pedro, García-Bengoechea, Manuel, Barrio, Jesús, Mújica, Fernando, Recondo, José A. · 2004 · Radiology

Abstract

PURPOSE: To evaluate the accuracy of magnetic resonance (MR) imaging in the quantification of hepatic iron concentration. MATERIALS AND METHODS: Between April 1999 and June 2001, 112 patients were recruited prospectively. All had undergone liver biopsy and hepatic iron concentration quantification with spectrophotometry, followed by MR imaging. MR imaging involved use of four gradient-echo sequences and one spin-echo sequence. Signal intensity (SI) was measured on images obtained with each sequence by means of regions of interest placed in the liver and paraspinal muscle to obtain the liver-to-muscle SI ratio. The relationship between hepatic iron concentration and SI ratio for each sequence was analyzed with multiple linear regression. Receiver operating characteristic analysis was performed to find the diagnostic thresholds. RESULTS: Sixty-eight patients had normal hepatic iron levels (<36 micromol/g), 23 had hemosiderosis (36-80 micromol/g), and 21 had hemochromatosis (>80 micromol/g). With all sequences, an inverse linear relationship between iron concentration and SI ratio was apparent. The authors generated a mathematic model to estimate the iron concentrations from MR imaging data (r = 0.937). For estimated concentrations of more than 85 micromol/g, the positive predictive value for hemochromatosis was 100%; for those less than 40 micromol/g, the negative predictive value for hemochromatosis was 100%. For estimated concentrations of more than 58 micromol/g, the positive predictive value for iron overload was 100%; for those less than 20 micromol/g, the negative predictive value for iron overload was 100%. CONCLUSION: MR imaging is a useful and noninvasive diagnostic tool for quantification of hepatic iron concentration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2302020820

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 228

Metadata

Authors
Alústiza, J. M., Artetxe, J., Castiella, A., Agirre, C., Emparanza, J. I., Otazua, P., García-Bengoechea, M., Barrio, J., Mújica, F., & Recondo, J. A.
Venue
Radiology
Published
2004-02
Volume
230
Issue
2
Pages
479-484
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1968365899
Cited by
228
References
2
FWCI
6.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MR Quantification of Hepatic Iron Concentration. https://app.cochat.ai/papers/10.1148/radiol.2302020820
The paper
Alústiza, J. M., Artetxe, J., Castiella, A., Agirre, C., Emparanza, J. I., Otazua, P., García-Bengoechea, M., Barrio, J., Mújica, F., & Recondo, J. A. (2004). MR Quantification of Hepatic Iron Concentration. Radiology. https://doi.org/10.1148/radiol.2302020820

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.