MR Imaging Relaxation Times of Abdominal and Pelvic Tissues Measured in Vivo at 3.0 T: Preliminary Results
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
PURPOSE: To measure T1 and T2 relaxation times of normal human abdominal and pelvic tissues and lumbar vertebral bone marrow at 3.0 T. MATERIALS AND METHODS: Relaxation time was measured in six healthy volunteers with an inversion-recovery method and different inversion times and a multiple spin-echo (SE) technique with different echo times to measure T1 and T2, respectively. Six images were acquired during one breath hold with a half-Fourier acquisition single-shot fast SE sequence. Signal intensities in regions of interest were fit to theoretical curves. Measurements were performed at 1.5 and 3.0 T. Relaxation times at 1.5 T were compared with those reported in the literature by using a one-sample t test. Differences in mean relaxation time between 1.5 and 3.0 T were analyzed with a two-sample paired t test. RESULTS: Relaxation times (mean +/- SD) at 3.0 T are reported for kidney cortex (T1, 1,142 msec +/- 154; T2, 76 msec +/- 7), kidney medulla (T1, 1,545 msec +/- 142; T2, 81 msec +/- 8), liver (T1, 809 msec +/- 71; T2, 34 msec +/- 4), spleen (T1, 1,328 msec +/- 31; T2, 61 msec +/- 9), pancreas (T1, 725 msec +/- 71; T2, 43 msec +/- 7), paravertebral muscle (T1, 898 msec +/- 33; T2, 29 msec +/- 4), bone marrow in L4 vertebra (T1, 586 msec +/- 73; T2, 49 msec +/- 4), subcutaneous fat (T1, 382 msec +/- 13; T2, 68 msec +/- 4), prostate (T1, 1,597 msec +/- 42; T2, 74 msec +/- 9), myometrium (T1, 1,514 msec +/- 156; T2, 79 msec +/- 10), endometrium (T1, 1,453 msec +/- 123; T2, 59 msec +/- 1), and cervix (T1, 1,616 msec +/- 61; T2, 83 msec +/- 7). On average, T1 relaxation times were 21% longer (P <.05) for kidney cortex, liver, and spleen and T2 relaxation times were 8% shorter (P <.05) for liver, spleen, and fat at 3.0 T; however, the fractional change in T1 and T2 relaxation times varied greatly with the organ. At 1.5 T, no significant differences (P >.05) in T1 relaxation time between the results of this study and the results of other studies for liver, kidney, spleen, and muscle tissue were found. CONCLUSION: T1 relaxation times are generally higher and T2 relaxation times are generally lower at 3.0 T than at 1.5 T, but the magnitude of change varies greatly in different tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bottomley, P. A., Foster, T. H., Argersinger, R. E., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595535 · Cited by 1,192
Signal‐to‐noise measurements in magnitude images from NMR phased arrays
Constantinides, C. D., Atalar, E., & McVeigh, E. R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380524 · Cited by 510
Focal fat deposition in axial bone marrow: MR characteristics.
Hájek, P., Baker, L. L., Goobar, J. E., Sartoris, D. J., Hesselink, J. R., Haghighi, P., & RESNICK, D. (1987) · Radiology · doi:10.1148/radiology.162.1.3786770 · Cited by 99
MR imaging contrast in human brain tissue: assessment and optimization at 4 T.
Duewell, S., Wolff, S. D., Wen, H.-Z., Balaban, R. S., & Jezzard, P. (1996) · Radiology · doi:10.1148/radiology.199.3.8638005 · Cited by 50
Kreeftenberg, H. G., Mooyaart, E. L., Huizenga, J. R., & Sluiter, W. J. (2000) · The Netherlands Journal of Medicine · doi:10.1016/s0300-2977(00)00003-6 · Cited by 44
Magnetic resonance properties of ex vivo breast tissue at 1.5 T
Graham, S. J., Ness, S., Hamilton, B. S., & Bronskill, M. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380422 · Cited by 39
Wansapura (1999) · doi:10.1002/(sici)1522-2586(199904)9:4
Cited by
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Diffusion-weighted MR Imaging of the Liver
Taouli, B., & Koh, D.-M. (2010) · Radiology · doi:10.1148/radiol.09090021 · Cited by 810
McRobbie, D. W., Moore, E. A., Graves, M. J., & Prince, M. R. (2017) · Cambridge University Press eBooks · doi:10.1017/9781107706958 · Cited by 752
Fat quantification with IDEAL gradient echo imaging: Correction of bias from T1 and noise
Liu, C., McKenzie, C. A., Yu, H., Brittain, J. H., & Reeder, S. B. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21301 · Cited by 477
Miyazaki, M., & Lee, V. S. (2008) · Radiology · doi:10.1148/radiol.2481071497 · Cited by 407
Metadata
- Authors
- de Bazelaire, C. M. J., Duhamel, G. D., Rofsky, N. M., & Alsop, D. C.
- Venue
- Radiology
- Published
- 2004-03
- Volume
- 230
- Issue
- 3
- Pages
- 652-659
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2130544939
- Cited by
- 792
- References
- 7
- FWCI
- 19.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.