Small Pulmonary Nodules: Reproducibility of Three-dimensional Volumetric Measurement and Estimation of Time to Follow-up CT

Kostis, William J., Yankelevitz, David F., Reeves, Anthony P., Fluture, Simina C., Henschke, Claudia I. · 2004 · Radiology

Abstract

PURPOSE: To determine reproducibility of volume measurements of small pulmonary nodules on computed tomographic (CT) scans and to estimate critical time to follow-up CT. MATERIALS AND METHODS: One hundred fifteen pulmonary nodules for which two thin-section small-field-of-view CT scans were obtained and which were stable during 2-year observation were evaluated. A standard group of 94 nodules (with no or minimal artifact) and an expanded group of 105 nodules (including those with moderate artifacts) were examined. Percentage volume change (PVC) and monthly volumetric growth index (MVGI) were computed for each nodule pair. By using estimates of the variation in PVC in stable nodules as a function of initial diameter, critical time to follow-up CT was estimated; this time is the earliest point at which growth in a nodule of a given size can be reliably identified with repeat CT. RESULTS: The SD of PVC decreased with increasing nodule size from 18.5% in 2-5-mm nodules to 10.6% in 5-8-mm nodules and to 7.47% in 8-10-mm nodules. Inclusion of cases with moderate motion artifacts increased the SD of PVC to 27.4% in 2-5-mm nodules, to 17.1% in 5-8-mm nodules, and to 19.3% in 8-10-mm nodules. Critical time to follow-up CT for nodules detected at baseline screening was 12, 5, and 3 months and 1 month for those with initial sizes of 2, 5, 8, and 10 mm, respectively. For nodules detected at annual repeat screening, it was 4 and 3 months and 1 month for nodules that were 3, 4, and 5 mm or larger in size, respectively. Mean MVGI in 94 standard cases was 0.06%, and standard error was 0.21%. CONCLUSION: Factors that affect reproducibility of nodule volume measurements and critical time to follow-up CT include nodule size at detection, type of scan (baseline or annual repeat) on which the nodule is detected, and presence of patient-induced artifacts.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2312030553

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 206

Metadata

Authors
Kostis, W. J., Yankelevitz, D. F., Reeves, A. P., Fluture, S. C., & Henschke, C. I.
Venue
Radiology
Published
2004-05
Volume
231
Issue
2
Pages
446-452
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2166928534
Cited by
206
References
0
FWCI
13.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Small Pulmonary Nodules: Reproducibility of Three-dimensional Volumetric Measurement and Estimation of Time to Follow-up CT. https://app.cochat.ai/papers/10.1148/radiol.2312030553
The paper
Kostis, W. J., Yankelevitz, D. F., Reeves, A. P., Fluture, S. C., & Henschke, C. I. (2004). Small Pulmonary Nodules: Reproducibility of Three-dimensional Volumetric Measurement and Estimation of Time to Follow-up CT. Radiology. https://doi.org/10.1148/radiol.2312030553

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.