The Image Biomarker Standardization Initiative: Standardized Convolutional Filters for Reproducible Radiomics and Enhanced Clinical Insights
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Filters are commonly used to enhance specific structures and patterns in images, such as vessels or peritumoral regions, to enable clinical insights beyond the visible image using radiomics. However, their lack of standardization restricts reproducibility and clinical translation of radiomics decision support tools. In this special report, teams of researchers who developed radiomics software participated in a three-phase study (September 2020 to December 2022) to establish a standardized set of filters. The first two phases focused on finding reference filtered images and reference feature values for commonly used convolutional filters: mean, Laplacian of Gaussian, Laws and Gabor kernels, separable and nonseparable wavelets (including decomposed forms), and Riesz transformations. In the first phase, 15 teams used digital phantoms to establish 33 reference filtered images of 36 filter configurations. In phase 2, 11 teams used a chest CT image to derive reference values for 323 of 396 features computed from filtered images using 22 filter and image processing configurations. Reference filtered images and feature values for Riesz transformations were not established. Reproducibility of standardized convolutional filters was validated on a public data set of multimodal imaging (CT, fluorodeoxyglucose PET, and T1-weighted MRI) in 51 patients with soft-tissue sarcoma. At validation, reproducibility of 486 features computed from filtered images using nine configurations × three imaging modalities was assessed using the lower bounds of 95% CIs of intraclass correlation coefficients. Out of 486 features, 458 were found to be reproducible across nine teams with lower bounds of 95% CIs of intraclass correlation coefficients greater than 0.75. In conclusion, eight filter types were standardized with reference filtered images and reference feature values for verifying and calibrating radiomics software packages. A web-based tool is available for compliance checking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 31,709
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Radiomics: Images Are More than Pictures, They Are Data
Gillies, R. J., Kinahan, P. E., & Hricak, H. (2016) · Radiology · doi:10.1148/radiol.2015151169 · Cited by 8,421
Forming inferences about some intraclass correlation coefficients.
McGraw, K. O., & Wong, S. P. (1996) · Psychological Methods · doi:10.1037/1082-989x.1.1.30 · Cited by 6,903
The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository
Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., Moore, S., Phillips, S., Maffitt, D., Pringle, M., et al. (2013) · Journal of Digital Imaging · doi:10.1007/s10278-013-9622-7 · Cited by 4,599 · cited 1×
“This cohort consisted of 51 patients with soft-tissue sarcoma obtained from The Cancer Imaging Archive (12–14).”
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177 · cited 7×
“…implication is that software labeled as “IBSI-compliant” is now expected to reproduce the reference filtered images and reference feature values found in our current study, insofar as convolutional filters are available in the software, in addition to the existing reference feature values (4).”
InfluentialSelf-citationRadiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
Self-citationThe Biological Meaning of Radiomic Features
Tomaszewski, M. R., & Gillies, R. J. (2021) · Radiology · doi:10.1148/radiol.2021219005 · Cited by 327
Zwanenburg, A. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04391-8 · Cited by 306
Self-citationBuilding reliable radiomic models using image perturbation
Teng, X., Zhang, J., Zwanenburg, A., Sun, J., Huang, Y., Lam, S., Zhang, Y., Li, B., Zhou, T., Xiao, H., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-14178-x · Cited by 40
Self-citation
Cited by
Bakas, S., Vollmuth, P., Galldiks, N., Booth, T. C., Aerts, H. J. W. L., Bi, W. L., Wiestler, B., Tiwari, P., Pati, S., Baid, U., et al. (2024) · The Lancet Oncology · doi:10.1016/s1470-2045(24)00315-2 · Cited by 36
Self-citation
Metadata
- Authors
- Whybra, P., Zwanenburg, A., Andrearczyk, V., Schaer, R., Apte, A. P., Ayotte, A., Baheti, B., Bakas, S., Bettinelli, A., Boellaard, R., Boldrini, L., Buvat, I., Cook, G. J. R., Dietsche, F., Dinapoli, N., Gabryś, H. S., Goh, V., Guckenberger, M., Hatt, M., Hosseinzadeh, M., Iyer, A., Lenkowicz, J., Loutfi, M. A. L., Löck, S., Marturano, F., Morin, O., Nioche, C., Orlhac, F., Pati, S., Rahmim, A., Rezaeijo, S. M., Rookyard, C. G., Salmanpour, M. R., Schindele, A., Shiri, I., Spezi, E., Tanadini-Lang, S., Tixier, F., Upadhaya, T., Valentini, V., van Griethuysen, J. J. M., Yousefirizi, F., Zaidi, H., Müller, H., Vallières, M., & Depeursinge, A.
- Venue
- Radiology
- Published
- 2024-02-01
- Volume
- 310
- Issue
- 2
- Pages
- e231319-e231319
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W4391577343
- Cited by
- 239
- References
- 10
- FWCI
- 54.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.