The DOI matches its Crossref record.
Screen-Film Mammography versus Full-Field Digital Mammography with Soft-Copy Reading: Randomized Trial in a Population-based Screening Program—The Oslo II Study
Abstract
PURPOSE: To prospectively compare cancer detection rates, recall rates, and positive predictive values at screen-film mammography (SFM) with those at full-field digital mammography (FFDM) with soft-copy reading in a population-based screening program in Norway. MATERIALS AND METHODS: Of 43,429 women invited, 25,263 women aged 45-69 years attended the screening program and were randomized, with adjustments for age and area of residence, to undergo SFM or FFDM. Two standard views of each breast were acquired. Independent double reading was performed with use of a five-point rating scale for probability of cancer. Recall rates, positive predictive values, and cancer detection rates were compared for two age groups (45-49 and 50-69 years) by using the chi(2) test. RESULTS: Overall, 73 cancers in 17,911 women were detected at SFM (detection rate, 0.41%), compared with 41 cancers in 6,997 women at FFDM (detection rate, 0.59%; P =.06). In the group aged 50-69 years, 56 cancers in 10,304 women were detected at SFM (detection rate, 0.54%), compared with 33 cancers in 3,985 at FFDM (detection rate, 0.83%); the difference in cancer detection rates approached significance (P =.053). In the group aged 45-49 years, 17 cancers in 7,607 women were detected at SFM (detection rate, 0.22%), compared with eight cancers in 3,012 at FFDM (detection rate, 0.27%). Recall rates in both age groups were significantly higher at FFDM than at SFM (P <.05), but positive predictive value was not significantly different. CONCLUSION: FFDM allowed a higher cancer detection rate than did SFM in the group aged 50-69, although the difference did not reach statistical significance. The detection rate was nearly equal for the two modalities in the group aged 45-49. SFM and FFDM with soft-copy reading are comparable techniques for population-based screening mammography programs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diagnostic Performance of Digital versus Film Mammography for Breast-Cancer Screening
Pisano, E. D., Gatsonis, C., Hendrick, E., Yaffe, M., Baum, J. K., Acharyya, S., Conant, E. F., Fajardo, L. L., Bassett, L., D'Orsi, C., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa052911 · Cited by 1,940
Elmore, J. G. (2005) · JAMA · doi:10.1001/jama.293.10.1245 · Cited by 1,075
Skaane, P., Bandos, A. I., Gullien, R., Eben, E. B., Ekseth, U., Haakenaasen, U., Izadi, M., Jebsen, I. N., Jahr, G., Krager, M., et al. (2013) · Radiology · doi:10.1148/radiol.12121373 · Cited by 1,012
Self-citationAndersson, I., Ikeda, D. M., Zackrisson, S., Ruschin, M., Svahn, T., Timberg, P., & Tingberg, A. (2008) · European Radiology · doi:10.1007/s00330-008-1076-9 · Cited by 343
Sechopoulos, I., Teuwen, J., & Mann, R. (2021) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2020.06.002 · Cited by 341
Skaane, P., Bandos, A. I., Eben, E. B., Jebsen, I. N., Krager, M., Haakenaasen, U., Ekseth, U., Izadi, M., Hofvind, S., & Gullien, R. (2014) · Radiology · doi:10.1148/radiol.13131391 · Cited by 332
Self-citationConsequences of false-positive screening mammograms
Tosteson, A. N. A., Fryback, D. G., Hammond, C. S., Hanna, L. G., Grove, M. R., Brown, M., Wang, Q., Lindfors, K., & Pisano, E. D. (2014) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2014.981 · Cited by 217
Metadata
- Authors
- Skaane, P., & Skjennald, A.
- Venue
- Radiology
- Published
- 2004-07
- Volume
- 232
- Issue
- 1
- Pages
- 197-204
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2069809202
- Cited by
- 236
- References
- 0
- FWCI
- 19.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.