Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 212

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Urinary Bladder Cancer: Preoperative Nodal Staging with Ferumoxtran-10–enhanced MR Imaging

Deserno, Willem M. L. L. G., Harisinghani, Mukesh G., Taupitz, Matthias, Jager, Gerrit J., Witjes, J. Alfred, Mulders, Peter F., Hulsbergen van de Kaa, Christina A., Kaufmann, D., Barentsz, Jelle O.·2004·Radiology

Abstract

PURPOSE: To prospectively evaluate ferumoxtran-10-enhanced magnetic resonance (MR) imaging for nodal staging in patients with urinary bladder cancer. MATERIALS AND METHODS: Fifty-eight patients with proved bladder cancer were enrolled. Results of MR imaging performed before and after injection of ferumoxtran-10 were compared with histopathologic results in surgically removed lymph nodes. High-spatial-resolution three-dimensional T1-weighted magnetization-prepared rapid acquisition gradient-echo (voxel size, 1.4 x 1.4 x 1.4 mm) and T2*-weighted gradient-echo (voxel size, 0.8 x 0.8 x 3.0 mm) sequences were performed before and 24 hours after injection of ferumoxtran-10 (2.6 mg iron per kilogram of body weight). On precontrast images, lymph nodes were defined as malignant by using size and shape criteria (round node, >8 mm; oval, >10 mm axial diameter). On postcontrast images, nodes were considered benign if there was homogeneous decrease in signal intensity and malignant if decrease was absent or heterogeneous. Qualitative evaluation was performed on a node-to-node basis. Sensitivity, specificity, predictive values, and accuracy were evaluated with logistic regression analysis. RESULTS: In 58 patients, 172 nodes imaged with use of ferumoxtran-10 were matched and correlated with results of node dissection. Of these, 122 were benign and 50 were malignant. With nodal size and shape criteria, accuracy, sensitivity, specificity, and positive and negative predictive values on precontrast images were 92%, 76%, 99%, 97%, and 91%, respectively; corresponding values on postcontrast images were 95%, 96%, 95%, 89%, and 98%. In the depiction of pelvic metastases, sensitivity and negative predictive value improved significantly at postcontrast compared with those at precontrast imaging, from 76% to 96% (P < .001) and from 91% to 98% (P < .01), respectively. At postcontrast imaging, metastases (4-9 mm) were prospectively found in 10 of 12 normal-sized nodes (<10 mm); these metastases were not detected on precontrast images. Postcontrast images also showed lymph nodes that were missed at pelvic node dissection in two patients. CONCLUSION: Ferumoxtran-10-enhanced MR imaging significantly improves nodal staging in patients with bladder cancer by depicting metastases even in normal-sized lymph nodes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2332031111

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 212

Metadata

Authors
Deserno, W. M. L. L. G., Harisinghani, M. G., Taupitz, M., Jager, G. J., Witjes, J. A., Mulders, P. F., Hulsbergen van de Kaa, C. A., Kaufmann, D., & Barentsz, J. O.
Venue
Radiology
Published
2004-11
Volume
233
Issue
2
Pages
449-456
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2108304907
Cited by
212
References
1
FWCI
16.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Urinary Bladder Cancer: Preoperative Nodal Staging with Ferumoxtran-10–enhanced MR Imaging. https://app.cochat.ai/papers/10.1148/radiol.2332031111
The paper
Deserno, W. M. L. L. G., Harisinghani, M. G., Taupitz, M., Jager, G. J., Witjes, J. A., Mulders, P. F., Hulsbergen van de Kaa, C. A., Kaufmann, D., & Barentsz, J. O. (2004). Urinary Bladder Cancer: Preoperative Nodal Staging with Ferumoxtran-10–enhanced MR Imaging. Radiology. https://doi.org/10.1148/radiol.2332031111

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.