Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 233

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Cardiac Functional Analysis with Multi–Detector Row CT and Segmental Reconstruction Algorithm: Comparison with Echocardiography, SPECT, and MR Imaging

Open access
Yamamuro, Masaki, Tadamura, Eiji, Kubo, Shigeto, Toyoda, Hiroshi, Nishina, Takeshi, Ohba, Muneo, Hosokawa, Ryohei, Kimura, Takeshi, Tamaki, Nagara, Komeda, Masashi, Kita, Toru, Konishi, Junji · 2005 · Radiology

Abstract

PURPOSE: To evaluate accuracy of cardiac functional analysis with multi-detector row computed tomography (CT) and segmental reconstruction algorithm over a range of heart rates. MATERIALS AND METHODS: Institutional review board approval was obtained. Informed consent was not required. Multi-detector row CT (500-msec rotation time, 8 x 1-mm detector collimation) and magnetic resonance (MR) imaging were performed in 50 patients (28 men, 22 women; age range, 46-84 years; mean age, 67 years). Two-dimensional echocardiography was performed in 41 patients, and electrocardiographically (ECG)-gated single photon emission computed tomography (SPECT) was performed in 27. End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), and left ventricular (LV) mass were estimated with multi-detector row CT and compared with values estimated with MR imaging, which served as the reference standard. Additionally, EF values estimated with multi-detector row CT, echocardiography, and SPECT were compared with those estimated with MR imaging. Systemic error and degree of agreement of global functional parameters measured with MR imaging and other modalities were assessed. In a second analysis, linear regression analysis was added. RESULTS: EF estimated with multi-detector row CT agreed and correlated well with EF estimated with MR imaging (bias +/- standard deviation, -1.2% +/- 4.6; r = 0.96). Agreement and correlation were similar for EDV (-0.35 mL +/- 15.2; r = 0.97), ESV (1.1 mL +/- 8.6; r = 0.99), and LV mass (2.5 mL +/- 15.0; r = 0.96). Standard deviation of EF difference between multi-detector row CT and MR imaging was significantly less than that between echocardiography and MR imaging (P < .001) or that between SPECT and MR imaging (P < .001). CONCLUSION: Various LV functional parameters were measured with multi-detector row CT with a segmental approach, and measurements correlated and agreed with those obtained with MR imaging. Moreover, functional analysis with multi-detector row CT was more accurate than that with two-dimensional echocardiography or ECG-gated SPECT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2342031271

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 233

Metadata

Authors
Yamamuro, M., Tadamura, E., Kubo, S., Toyoda, H., Nishina, T., Ohba, M., Hosokawa, R., Kimura, T., Tamaki, N., Komeda, M., Kita, T., & Konishi, J.
Venue
Radiology
Published
2005-02
Volume
234
Issue
2
Pages
381-390
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2167192254
Cited by
233
References
1
FWCI
22.14
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiac Functional Analysis with Multi–Detector Row CT and Segmental Reconstruction Algorithm: Comparison with Echocardiography, SPECT, and MR Imaging. https://app.cochat.ai/papers/10.1148/radiol.2342031271
The paper
Yamamuro, M., Tadamura, E., Kubo, S., Toyoda, H., Nishina, T., Ohba, M., Hosokawa, R., Kimura, T., Tamaki, N., Komeda, M., Kita, T., & Konishi, J. (2005). Cardiac Functional Analysis with Multi–Detector Row CT and Segmental Reconstruction Algorithm: Comparison with Echocardiography, SPECT, and MR Imaging. Radiology. https://doi.org/10.1148/radiol.2342031271

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.