The DOI matches its Crossref record; 159 of the 159 references it cites were found in a registry or an index.
CT of Coronary Artery Disease
Abstract
The socioeconomic importance of heart disease provides considerable motivation for development of radiologic tools for noninvasive imaging of the coronary arteries. Current computed tomographic (CT) techniques combine high speed and spatial resolution with sophisticated electrocardiographic synchronization and robustness of use. Application of these modalities for evaluation of coronary artery disease is a topic of active current research. Coronary artery calcium measurements with different CT techniques have been used for determining the risk of coronary events, but the exact role of this marker for cardiac risk stratification remains unclear pending results of population-based studies. Contrast material-enhanced CT coronary angiography has become an established clinical indication for some scenarios (eg, coronary artery anomalies, bypass patency, surgical planning). With current technology, the accuracy of CT coronary angiography for detection of coronary artery stenoses appears promising enough to warrant pursuit of this application, but sensitivity is still not high enough for routine diagnostic needs. The high negative predictive value of a normal CT coronary angiogram, however, may be useful for reliable exclusion of coronary artery stenosis. The cross-sectional nature of CT may allow noninvasive assessment of the coronary artery wall. Use of contrast-enhanced CT coronary angiography for detection, characterization, and quantification of atherosclerotic changes and total disease burden in coronary arteries as a potential tool for cardiac risk stratification is currently being investigated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786
American Heart Association Writing Group on Myocardial Segmentation and Registration for Cardiac Imaging:, Cerqueira, M. D., Weissman, N. J., Dilsizian, V., Jacobs, A. K., Kaul, S., Laskey, W. K., Pennell, D. J., Rumberger, J. A., Ryan, T., et al. (2002) · Circulation · doi:10.1161/hc0402.102975 · Cited by 6,990
Virmani, R., Kolodgie, F. D., Burke, A. P., Farb, A., & Schwartz, S. M. (2000) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.20.5.1262 · Cited by 4,084
Multi-Ethnic Study of Atherosclerosis: Objectives and Design
Bild, D. E. (2002) · American Journal of Epidemiology · doi:10.1093/aje/kwf113 · Cited by 3,942
Stary, H. C., Chandler, A. B., Dinsmore, R. E., Fuster, V., Glagov, S., Insull, W., Rosenfeld, M. E., Schwartz, C. J., Wagner, W. D., & Wissler, R. W. (1995) · Circulation · doi:10.1161/01.cir.92.5.1355 · Cited by 3,533
Kim, R. J., Wu, E., Rafael, A., Chen, E.-L., Parker, M. A., Simonetti, O., Klocke, F. J., Bonow, R. O., & Judd, R. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011163432003 · Cited by 3,306
Antman, E. M., Cohen, M., Bernink, P. J. L. M., McCabe, C. H., Horacek, T., Papuchis, G., Mautner, B., Corbalan, R., Radley, D., & Braunwald, E. (2000) · JAMA · doi:10.1001/jama.284.7.835 · Cited by 3,242
Naghavi, M., Libby, P., Falk, E., Casscells, S. W., Litovsky, S., Rumberger, J., Badimon, J. J., Stefanadis, C., Moreno, P., Pasterkamp, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000087481.55887.c9 · Cited by 2,668
Self-citationKim, R. J., Fieno, D. S., Parrish, T. B., Harris, K., Chen, E.-L., Simonetti, O., Bundy, J., Finn, J. P., Klocke, F. J., & Judd, R. M. (1999) · Circulation · doi:10.1161/01.cir.100.19.1992 · Cited by 2,581
White, H. D., Norris, R. M., Brown, M. A., Brandt, P. W., Whitlock, R. M., & Wild, C. J. (1987) · Circulation · doi:10.1161/01.cir.76.1.44 · Cited by 2,363
Cited by
Min, J. K., Shaw, L. J., Devereux, R. B., Okin, P. M., Weinsaft, J. W., Russo, D. J., Lippolis, N. J., Berman, D. S., & Callister, T. Q. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.03.067 · Cited by 1,055
Accuracy of MSCT coronary angiography with 64-slice technology: first experience
Leschka, S., Alkadhi, H., Plass, A., Desbiolles, L., Grünenfelder, J., Marincek, B., & Wildermuth, S. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi261 · Cited by 960
Schroeder, S., Achenbach, S., Bengel, F., Burgstahler, C., Cademartiri, F., de Feyter, P., George, R., Kaufmann, P., Kopp, A. F., Knuuti, J., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehm544 · Cited by 554
Noninvasive Coronary Angiography With Multislice Computed Tomography
Hoffmann, M. H. K. (2005) · JAMA · doi:10.1001/jama.293.20.2471 · Cited by 507
Multi–Detector Row CT Systems and Image-Reconstruction Techniques
Flohr, T. G., Schaller, S., Stierstorfer, K., Bruder, H., Ohnesorge, B. M., & Schoepf, U. J. (2005) · Radiology · doi:10.1148/radiol.2353040037 · Cited by 381
Self-citation
Metadata
- Authors
- Schoepf, U. J., Becker, C. R., Ohnesorge, B. M., & Yucel, E. K.
- Venue
- Radiology
- Published
- 2004-07
- Volume
- 232
- Issue
- 1
- Pages
- 18-37
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2149949137
- Cited by
- 356
- References
- 159
- FWCI
- 39.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CT of Coronary Artery Disease. https://app.cochat.ai/papers/10.1148/radiol.2321030636
- The paper
- Schoepf, U. J., Becker, C. R., Ohnesorge, B. M., & Yucel, E. K. (2004). CT of Coronary Artery Disease. Radiology. https://doi.org/10.1148/radiol.2321030636
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.