Imaging of Macrophages in Soft-Tissue Infection in Rats: Relationship between Ultrasmall Superparamagnetic Iron Oxide Dose and MR Signal Characteristics
The DOI matches its Crossref record.
Abstract
PURPOSE: To describe dose-dependent signal intensity (SI) characteristics of experimentally induced soft-tissue abscesses on 1.5-T T1- and T2*-weighted magnetic resonance (MR) images obtained 24 hours after administration of ultrasmall superparamagnetic iron oxide (USPIO) and to describe the relationship between SI and amount of USPIO uptake and macrophage iron content. MATERIALS AND METHODS: Local institutional review committee on animal care approved the experiments, which were performed according to the guidelines of the National Institutes of Health and the committee on animal research at our institution. Unilateral calf muscle abscesses were induced in 21 rats with an injection of a Staphylococcus aureus suspension. The rats were divided into three groups of seven animals each: low USPIO dose (50 micromol of iron per kilogram of body weight), high USPIO dose (150 micromol Fe/kg), and control (saline solution). All rats were imaged before and 24 hours after USPIO administration at 1.5 T (transverse T1-weighted spin-echo, T2*-weighted fast gradient-echo, and short inversion time inversion-recovery sequences). Images were analyzed quantitatively and qualitatively with regard to SI and signal pattern. Temporal variation of calculated contrast-to-noise ratios was analyzed with the Wilcoxon signed rank test. MR findings were correlated with histopathologic findings, including those of electron microscopy. RESULTS: Twenty-four hours after USPIO administration in the high-dose group, susceptibility effects were present in abscess periphery on postcontrast T2*-weighted images (P=.04), and SI enhancement was noted on postcontrast T1-weighted images within both abscess wall and abscess center (P=.04 for both). In the low-dose group, SI enhancement was noted in entire abscess on T1-weighted postcontrast images (P=.03). Neither significant SI loss (P=.09) nor susceptibility effects were detected in periphery or center of any abscess on postcontrast T2*-weighted images. There was no obvious difference in total amount of macrophages among the groups, but there was a clear difference with regard to individual iron content of iron-positive macrophages between the USPIO dose groups. CONCLUSION: At 1.5 T, SI characteristics of abscesses on T1- and T2*-weighted images obtained 24 hours after USPIO injection strongly depend on administered dose of the contrast agent. At low doses, T1 effects were stronger than T2* effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent advances in iron oxide nanocrystal technology for medical imaging☆
COROT, C., ROBERT, P., IDEE, J., & PORT, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,465
Engineering applications of ferrofluids: A review
Kole, M., & Khandekar, S. (2021) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2021.168222 · Cited by 283
Evanics, F., Diamente, P. R., van Veggel, F. C. J. M., Stanisz, G. J., & Prosser, R. S. (2006) · Chemistry of Materials · doi:10.1021/cm052299w · Cited by 274
A Review of Magnetic Particle Imaging and Perspectives on Neuroimaging
Wu, L. C., Zhang, Y., Steinberg, G., Qu, H., Huang, S., Cheng, M., Bliss, T., Du, F., Rao, J., Song, G., et al. (2019) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5896 · Cited by 205
“Previous studies have used MR imaging to detect the SPIONs for inflammation tracking.(49,50,53,54) However, with high magnetic susceptibility, SPIOs cause a decrease in signal intensity, which could often be confused with signal voids from bone, air bubbles, susceptibility blowouts, and imaging artifacts.”
MethodIron-based superparamagnetic nanoparticle contrast agents for MRI of infection and inflammation
Neuwelt, A., Sidhu, N., Hu, C.-A. A., Mlady, G., Eberhardt, S. C., & Sillerud, L. O. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.14.12733 · Cited by 189
Metadata
- Authors
- Lutz, A. M., Weishaupt, D., Persohn, E., Goepfert, K., Froehlich, J., Sasse, B., Gottschalk, J., Marincek, B., & Kaim, A. H.
- Venue
- Radiology
- Published
- 2005-03
- Volume
- 234
- Issue
- 3
- Pages
- 765-775
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2139550491
- Cited by
- 52
- References
- 0
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging of Macrophages in Soft-Tissue Infection in Rats: Relationship between Ultrasmall Superparamagnetic Iron Oxide Dose and MR Signal Characteristics. https://app.cochat.ai/papers/10.1148/radiol.2343031172
- The paper
- Lutz, A. M., Weishaupt, D., Persohn, E., Goepfert, K., Froehlich, J., Sasse, B., Gottschalk, J., Marincek, B., & Kaim, A. H. (2005). Imaging of Macrophages in Soft-Tissue Infection in Rats: Relationship between Ultrasmall Superparamagnetic Iron Oxide Dose and MR Signal Characteristics. Radiology. https://doi.org/10.1148/radiol.2343031172
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.