The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Interventricular Septal Configuration at MR Imaging and Pulmonary Arterial Pressure in Pulmonary Hypertension
Abstract
PURPOSE: To investigate whether a relationship exists between septum shape and systolic pulmonary arterial pressure (PAP) in patients with pulmonary hypertension. MATERIALS AND METHODS: Study protocol was approved by institutional ethics review committee; all patients gave informed consent. Right-sided heart catheterization with vasodilator testing was performed in 39 adult subjects suspected of having pulmonary hypertension. There were 11 men and 28 women, aged 21-75 years (mean, 46 years). Only two patients showed favorable response to vasodilators, defined by a decrease in PAP of more than 20%. Synchronous right- and left-ventricular pressure measurements and four-chamber magnetic resonance (MR) imaging were used to identify timing of maximal leftward ventricular septal bowing within cardiac cycle. Septal bowing was evaluated with MR, measured on short-axis cine heart images, and expressed as curvature (reciprocal of radius). Curvature was quantified on one image (the one that showed the most severe distortion of normal septal shape). The relationship between systolic PAP and septal curvature was tested with linear regression analysis. P <.05 was considered to indicate a statistically significant difference. RESULTS: Of 39 subjects, 37 had pulmonary hypertension. Maximal distortion of normal septal shape was found during right ventricular relaxation phase. Systolic PAP was proportional to septal curvature: r=0.77 (P < .001), slope=-114.7, and intercept=67.2. In the two vasodilator responsive subjects, a significant reduction of leftward ventricular septal bowing was observed in response to reduction of right ventricular pressure. CONCLUSION: In 37 patients with pulmonary hypertension, systolic PAP higher than 67 mm Hg may be expected when leftward curvature is observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Interventricular Mechanical Asynchrony in Pulmonary Arterial Hypertension
Marcus, J. T., Gan, C. T.-J., Zwanenburg, J. J. M., Boonstra, A., Allaart, C. P., Götte, M. J. W., & Vonk-Noordegraaf, A. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.041 · Cited by 406
Self-citationTji-Joong Gan, C., Lankhaar, J.-W., Marcus, J. T., Westerhof, N., Marques, K. M., Bronzwaer, J. G. F., Boonstra, A., Postmus, P. E., & Vonk-Noordegraaf, A. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01031.2005 · Cited by 306
Self-citationContrast enhanced-cardiovascular magnetic resonance imaging in patients with pulmonary hypertension
Blyth, K. G., Groenning, B. A., Martin, T. N., Foster, J. E., Mark, P. B., Dargie, H. J., & Peacock, A. J. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi328 · Cited by 226
Metadata
- Authors
- Roeleveld, R. J., Marcus, J. T., Faes, T. J. C., Gan, T.-J., Boonstra, A., Postmus, P. E., & Vonk-Noordegraaf, A.
- Venue
- Radiology
- Published
- 2005-03
- Volume
- 234
- Issue
- 3
- Pages
- 710-717
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1972248754
- Cited by
- 215
- References
- 1
- FWCI
- 10.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interventricular Septal Configuration at MR Imaging and Pulmonary Arterial Pressure in Pulmonary Hypertension. https://app.cochat.ai/papers/10.1148/radiol.2343040151
- The paper
- Roeleveld, R. J., Marcus, J. T., Faes, T. J. C., Gan, T.-J., Boonstra, A., Postmus, P. E., & Vonk-Noordegraaf, A. (2005). Interventricular Septal Configuration at MR Imaging and Pulmonary Arterial Pressure in Pulmonary Hypertension. Radiology. https://doi.org/10.1148/radiol.2343040151
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.